Abstract
A permanent magnet homopolar inductor machine (PMHIM) can operate at extremely high speeds due to its simple and robust rotor. However, the reliability of the machine at high speeds would be seriously affected by electromagnetic vibration. Aiming at this problem, the electromagnetic vibration mechanism of PMHIM and its suppression methods are studied in this article. First, the unilateral air gap electromagnetic force density (EFD) of PMHIM is established. The odd-order component of the specific permeability function causes the (2 k -1)* p -order EFD harmonics to be generated in the unilateral air gap. Second, staggered-rotor (S-R) and trapezoidal rotor (T-R) are proposed to suppress the EFD harmonics. Only the zero-order vibration harmonics (ZOVHs) can be suppressed by S-R. Both ZOVHs and pole-frequency harmonics can be suppressed by T-R. Third, the influence of S-R and T-R on the performance of PMHIM is comprehensively studied based on the finite element analysis. Finally, the effectiveness of the proposed rotors for suppressing vibration is verified by experiments. The results show that both the proposed S-R and T-R can effectively suppress the vibration, which further promotes the application of PMHIM in high-speed fields.
Funding Information
  • National Natural Science Foundation of China (52007055)
  • Youth Cultivation Fund of Chinese Academy of Sciences (E224821231)

This publication has 20 references indexed in Scilit: