Jianzong Yu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jianzong Yu has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Jiangtao Yang
Hunan University
14 shared publications - Shoudao Huang
Hunan University
14 shared publications - Qing Li
College of Electrical and Information Engineering, Hunan University, Changsha, China
8 shared publications - Sheng Huang
Hunan University
5 shared publications - Chuang Gao
Shanghai Advanced Research Institute, Chinese Academy of Sciences, Shanghai, China
3 shared publications Peng Zhang
China Aviation Power Machinery Research Institute
3 shared publications
Latest Publications
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 62 (10) , 8600406
A Multi-Segment Minimum Copper Loss Fault-Tolerance Strategy for Full-Torque-Range Operation of Dual Star–Delta Windings PMSM Under Open-Phase Fault
When a single open-phase fault occurs in a dual star-delta windings permanent magnet synchronous motor (DSDW-PMSM), the yaxis current in the maximum torque fault-tolerant strategy is not decoupled from the currents on the α-axis and β-axis. As a result, the conventional hybrid current fault-tolerant strategy across the full torque range cannot achieve minimum copper loss output for this type of motor. To address this issue, this paper proposes a multi-segmented hybrid current fault-tolerant strategy, which ensures that the motor can output across the full torque range while minimizing the total copper loss generated by the windings. Furthermore, finite element simulation analysis is conducted to compare the torque ripple and radial electromagnetic force density of the existing hybrid current fault-tolerant strategies. Finally, tests are conducted on a 24-slot/10-pole DSDW-PMSM with a 15° phase shift to verify the feasibility of the proposed strategy.
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 62 (10) , 8600406
A Multi-Segment Minimum Copper Loss Fault-Tolerance Strategy for Full-Torque-Range Operation of Dual Star–Delta Windings PMSM Under Open-Phase Fault
When a single open-phase fault occurs in a dual star-delta windings permanent magnet synchronous motor (DSDW-PMSM), the yaxis current in the maximum torque fault-tolerant strategy is not decoupled from the currents on the α-axis and β-axis. As a result, the conventional hybrid current fault-tolerant strategy across the full torque range cannot achieve minimum copper loss output for this type of motor. To address this issue, this paper proposes a multi-segmented hybrid current fault-tolerant strategy, which ensures that the motor can output across the full torque range while minimizing the total copper loss generated by the windings. Furthermore, finite element simulation analysis is conducted to compare the torque ripple and radial electromagnetic force density of the existing hybrid current fault-tolerant strategies. Finally, tests are conducted on a 24-slot/10-pole DSDW-PMSM with a 15° phase shift to verify the feasibility of the proposed strategy.
- 9 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. PP (08858969) , 1-13
Adaptive Fault-Tolerant Control Based on Model-Free Predictive Current Control for PMSM with Dual Star-Delta Windings
This paper proposes a model-free predictive current control combined with an adaptive fault-tolerant control (AFTC-MFPCC) strategy for dual star-delta windings permanent magnet synchronous motor (DSDW-PMSM) under different phase shift angles. The proposed strategy enhances the operational performance of this motor when current sensor fault or open-phase fault occur in any star-connected winding phase, showing strong adaptability and robustness. Firstly, the invariance of the fundamental magnetomotive force (MMF) under single open-phase fault in DSDW-PMSM with different phase shift angles is analytically derived. Secondly, an adaptive fault-tolerant control strategy is proposed. Upon detecting a persistent zero current in any phase, it switches the adaptive fault-tolerant transformation matrix without explicit fault diagnosis, thereby avoiding the impact of current sensor faults and reducing the fault detection time. Subsequently, the xy-axis reference values are modified through current feedback, enabling the motor to adaptively transition from the fault state to the normal operation state. Furthermore, model-free predictive current control is employed to replace traditional PI control or deadbeat predictive current control in the current loop module of the vector control structure, which outputs four voltage vectors. This method avoids current tracking errors and severe waveform distortion caused by inaccuracies in motor parameter inputs. Finally, tests are conducted on a 24-slot/10-pole DSDW-PMSM with a 15° phase shift to validate the feasibility of the proposed method.
- 9 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. PP (08858969) , 1-13
Adaptive Fault-Tolerant Control Based on Model-Free Predictive Current Control for PMSM with Dual Star-Delta Windings
This paper proposes a model-free predictive current control combined with an adaptive fault-tolerant control (AFTC-MFPCC) strategy for dual star-delta windings permanent magnet synchronous motor (DSDW-PMSM) under different phase shift angles. The proposed strategy enhances the operational performance of this motor when current sensor fault or open-phase fault occur in any star-connected winding phase, showing strong adaptability and robustness. Firstly, the invariance of the fundamental magnetomotive force (MMF) under single open-phase fault in DSDW-PMSM with different phase shift angles is analytically derived. Secondly, an adaptive fault-tolerant control strategy is proposed. Upon detecting a persistent zero current in any phase, it switches the adaptive fault-tolerant transformation matrix without explicit fault diagnosis, thereby avoiding the impact of current sensor faults and reducing the fault detection time. Subsequently, the xy-axis reference values are modified through current feedback, enabling the motor to adaptively transition from the fault state to the normal operation state. Furthermore, model-free predictive current control is employed to replace traditional PI control or deadbeat predictive current control in the current loop module of the vector control structure, which outputs four voltage vectors. This method avoids current tracking errors and severe waveform distortion caused by inaccuracies in motor parameter inputs. Finally, tests are conducted on a 24-slot/10-pole DSDW-PMSM with a 15° phase shift to validate the feasibility of the proposed method.
- 9 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 12 (1) , 603-616
Novel In-Slot Direct Cooling Structure of Concentrated Winding Permanent Magnet Electrical Machine for Aerospace Propulsion
With the development of high-power-density electrical machines, in-slot direct cooling has become a key method to overcome power density limitations. To further enhance the thermal performance of stator oil direct cooling, three novel cooling structures are proposed and systematically compared, with the optimal structure being identified. The structure introduces tooth- and wedge-side oil paths to increase the contact area between the winding and coolant, and further incorporates oil-blocking teeth at the slot bottom to adjust the flow rate and velocity distribution of different paths. First, three novel direct cooling structures and a conventional structure are introduced, and their coolant flow paths are analyzed. To simplify modeling, a thermal conductivity equivalent model for formed litz wires is developed and validated. In addition, electromagnetic and mechanical performance are evaluated. Finite element results show stable torque across all designs, while harmonic response analysis indicates that the added features enhance stiffness and reduce vibration near excitation frequencies. Computational fluid dynamic (CFD) simulations are then conducted to assess flow distribution, coolant velocity, and temperature under various conditions. Results show that the proposed structures effectively reduce winding temperature rise. A stator tooth-slot module is also tested, and the experimental results align well with simulations, validating the analysis and thermal model.
- 9 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 12 (1) , 603-616
Novel In-Slot Direct Cooling Structure of Concentrated Winding Permanent Magnet Electrical Machine for Aerospace Propulsion
With the development of high-power-density electrical machines, in-slot direct cooling has become a key method to overcome power density limitations. To further enhance the thermal performance of stator oil direct cooling, three novel cooling structures are proposed and systematically compared, with the optimal structure being identified. The structure introduces tooth- and wedge-side oil paths to increase the contact area between the winding and coolant, and further incorporates oil-blocking teeth at the slot bottom to adjust the flow rate and velocity distribution of different paths. First, three novel direct cooling structures and a conventional structure are introduced, and their coolant flow paths are analyzed. To simplify modeling, a thermal conductivity equivalent model for formed litz wires is developed and validated. In addition, electromagnetic and mechanical performance are evaluated. Finite element results show stable torque across all designs, while harmonic response analysis indicates that the added features enhance stiffness and reduce vibration near excitation frequencies. Computational fluid dynamic (CFD) simulations are then conducted to assess flow distribution, coolant velocity, and temperature under various conditions. Results show that the proposed structures effectively reduce winding temperature rise. A stator tooth-slot module is also tested, and the experimental results align well with simulations, validating the analysis and thermal model.
- 23 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 41 (1) , 337-346
Electromagnetic Performance Analysis of Modular Permanent Magnet Machine With Nonuniform Stator Opening Using Conformal Mapping
Modular permanent magnet (PM) machines have attracted attention due to their merits of fault-tolerant performance, easy assembly, and convenient maintenance. However, the modular PM machine with a nonuniform stator opening causes difficulty for accurate analytical analysis of its electromagnetic performance. Addressing this issue, an analytical analysis method using conformal mapping considering nonuniform stator opening of modular PM machines is proposed. Firstly, the method for deriving the air gap flux density using complex relative permeance is presented. Secondly, the conversion of slotted to unslotted using the conformal mapping is analyzed in detail, as is the resulting complex relative permeance. Thirdly, the pattern of change in the air gap of the complex permeance is summarized. The electromagnetic performance, including air gap flux density, back electromagnetic force, cogging torque, and electromagnetic torque of a modular PM machine, is calculated by the proposed method, which is consistent with that obtained by simulation. Finally, a 10 kW modular PM machine is tested, which further validates the proposed method.
- 23 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 41 (1) , 337-346
Electromagnetic Performance Analysis of Modular Permanent Magnet Machine With Nonuniform Stator Opening Using Conformal Mapping
Modular permanent magnet (PM) machines have attracted attention due to their merits of fault-tolerant performance, easy assembly, and convenient maintenance. However, the modular PM machine with a nonuniform stator opening causes difficulty for accurate analytical analysis of its electromagnetic performance. Addressing this issue, an analytical analysis method using conformal mapping considering nonuniform stator opening of modular PM machines is proposed. Firstly, the method for deriving the air gap flux density using complex relative permeance is presented. Secondly, the conversion of slotted to unslotted using the conformal mapping is analyzed in detail, as is the resulting complex relative permeance. Thirdly, the pattern of change in the air gap of the complex permeance is summarized. The electromagnetic performance, including air gap flux density, back electromagnetic force, cogging torque, and electromagnetic torque of a modular PM machine, is calculated by the proposed method, which is consistent with that obtained by simulation. Finally, a 10 kW modular PM machine is tested, which further validates the proposed method.
- 18 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 11 (4) , 9949-9962
Influence of Phase Shift Angle on Performance of Permanent-Magnet Machine With Multiple Star-Delta Windings for Electric Vehicle Drive
The different phase shift angles among subwindings of machine with multiple star-delta connection (MSDC) can result in varied winding connections, thereby introducing different output performance and reliability. The influence of phase shift angle on performance of MSDC machine with any number of sub-windings is systematically investigated in this paper. Firstly, the possible phase shift angle laws of different pole-slot combinations and any number of sub-windings is given, and the mechanism of its influence on performance is analyzed. Then, the corresponding rules for eliminating armature magnetomotive force (AMMF) harmonics with different number of sub-windings and phase shift angles are presented. Moreover, the performance of different number of sub-windings machines with different phase shift angles are analyzed, including the harmonics of AMMF, output torque, torque ripple, loss, fault tolerance, vibration, etc. It is found that MSDC windings with a phase shift angle of 30/i (i is the number of independent sets of sub-windings) electrical degrees can maximize the output torque, minimize the torque ripple and eddy current loss of PM. Finally, a 24-slot/10-pole MSDC-PMSM prototype with a phase shift angle of 15 and 60 electrical degrees is tested, which verifies the reasonableness of the theoretical and simulation analyses.
- 18 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 11 (4) , 9949-9962
Influence of Phase Shift Angle on Performance of Permanent-Magnet Machine With Multiple Star-Delta Windings for Electric Vehicle Drive
The different phase shift angles among subwindings of machine with multiple star-delta connection (MSDC) can result in varied winding connections, thereby introducing different output performance and reliability. The influence of phase shift angle on performance of MSDC machine with any number of sub-windings is systematically investigated in this paper. Firstly, the possible phase shift angle laws of different pole-slot combinations and any number of sub-windings is given, and the mechanism of its influence on performance is analyzed. Then, the corresponding rules for eliminating armature magnetomotive force (AMMF) harmonics with different number of sub-windings and phase shift angles are presented. Moreover, the performance of different number of sub-windings machines with different phase shift angles are analyzed, including the harmonics of AMMF, output torque, torque ripple, loss, fault tolerance, vibration, etc. It is found that MSDC windings with a phase shift angle of 30/i (i is the number of independent sets of sub-windings) electrical degrees can maximize the output torque, minimize the torque ripple and eddy current loss of PM. Finally, a 24-slot/10-pole MSDC-PMSM prototype with a phase shift angle of 15 and 60 electrical degrees is tested, which verifies the reasonableness of the theoretical and simulation analyses.
- 22 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 72 (5) , 4567-4576
A Two-Terminal Hybrid Parallel Connection Method for Simultaneously Enhancing the Output Performance and Fault Tolerance of Dual Three-Phase Machines
Electric machines have long been a focal point for achieving both high output performance and robust fault tolerance, despite the inherent conflict between these two aspects in most scenarios. This article proposes a winding connection method called the two-terminal hybrid parallel connection method (THPCM). THPCM offers lower space harmonics of armature magnetomotive force (MMF) and a higher fundamental amplitude compared with conventional winding connection methods. It also demonstrates enhanced fault tolerance under adverse conditions. THPCM divides the winding into three parts: the first is like traditional machines, while the second and third create parallel paths with star-delta connections. The principles behind harmonic elimination in this method are deduced, and the mechanisms for improving output performance and fault tolerance are explained. Subsequently, the armature MMF distribution and output performance of traditional three-phase, star-delta, dual three-phase, and THPCM machines under normal operating conditions are compared by finite element method. Additionally, the fault tolerance of machines under open-circuit faults and interturn short-circuit faults is investigated. Results confirm the good output performance and fault tolerance of THPCM. Finally, a prototype THPCM machine is manufactured and tested, with experimental results closely aligning with simulation outcomes, validating the reliability of the theoretical and simulation analyses.
- 22 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 72 (5) , 4567-4576
A Two-Terminal Hybrid Parallel Connection Method for Simultaneously Enhancing the Output Performance and Fault Tolerance of Dual Three-Phase Machines
Electric machines have long been a focal point for achieving both high output performance and robust fault tolerance, despite the inherent conflict between these two aspects in most scenarios. This article proposes a winding connection method called the two-terminal hybrid parallel connection method (THPCM). THPCM offers lower space harmonics of armature magnetomotive force (MMF) and a higher fundamental amplitude compared with conventional winding connection methods. It also demonstrates enhanced fault tolerance under adverse conditions. THPCM divides the winding into three parts: the first is like traditional machines, while the second and third create parallel paths with star-delta connections. The principles behind harmonic elimination in this method are deduced, and the mechanisms for improving output performance and fault tolerance are explained. Subsequently, the armature MMF distribution and output performance of traditional three-phase, star-delta, dual three-phase, and THPCM machines under normal operating conditions are compared by finite element method. Additionally, the fault tolerance of machines under open-circuit faults and interturn short-circuit faults is investigated. Results confirm the good output performance and fault tolerance of THPCM. Finally, a prototype THPCM machine is manufactured and tested, with experimental results closely aligning with simulation outcomes, validating the reliability of the theoretical and simulation analyses.
- 4 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 60 (6) , 8766-8775
Analysis of Two-Terminal Hybrid Connection Method for Reducing Armature MMF Space Harmonics of Six-Phase Electric Machine
Fractional-slot windings, widely applied in multiphase electric machines, can further reduce cogging torque. However, concerns arise from the adverse effects of space harmonics introduced by the rich armature winding magnetomotive force (MMF). To reduce the space harmonics of armature winding MMF, a Two-terminal Hybrid Connection Method (TTHCM) of fractional slot electrical machine is proposed. Firstly, the general principle of harmonic elimination is derived, outlining the specific armature MMF harmonic orders that TTHCM can eliminate under different pole-slot combinations. Taking the example of a machine with 24-slot/10-pole configuration, the analysis process is presented. And the harmonic orders eliminated include the 1 st , 7 th , 11 th , 13 th , 17 th , 23 rd , and 25th space harmonics of the armature MMF. Next, models for a conventional three-phase machine, star-delta, dual three-phase, and TTHCM are established and compared. It is demonstrated that, compared to the dual three-phase connection, the TTHCM can enhance the torque, reduce torque ripple, decrease permanent magnet eddy current loss, and improve vibration performance without increasing the complexity of the control system. Finally, a prototype of TTHCM machine is manufactured and tested. The reliability of the theoretical and simulation analyses is confirmed.
- 4 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 60 (6) , 8766-8775
Analysis of Two-Terminal Hybrid Connection Method for Reducing Armature MMF Space Harmonics of Six-Phase Electric Machine
Fractional-slot windings, widely applied in multiphase electric machines, can further reduce cogging torque. However, concerns arise from the adverse effects of space harmonics introduced by the rich armature winding magnetomotive force (MMF). To reduce the space harmonics of armature winding MMF, a Two-terminal Hybrid Connection Method (TTHCM) of fractional slot electrical machine is proposed. Firstly, the general principle of harmonic elimination is derived, outlining the specific armature MMF harmonic orders that TTHCM can eliminate under different pole-slot combinations. Taking the example of a machine with 24-slot/10-pole configuration, the analysis process is presented. And the harmonic orders eliminated include the 1 st , 7 th , 11 th , 13 th , 17 th , 23 rd , and 25th space harmonics of the armature MMF. Next, models for a conventional three-phase machine, star-delta, dual three-phase, and TTHCM are established and compared. It is demonstrated that, compared to the dual three-phase connection, the TTHCM can enhance the torque, reduce torque ripple, decrease permanent magnet eddy current loss, and improve vibration performance without increasing the complexity of the control system. Finally, a prototype of TTHCM machine is manufactured and tested. The reliability of the theoretical and simulation analyses is confirmed.
- 12 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 72 (1) , 155-166
Investigation and Suppression of Electromagnetic Vibration of Permanent Magnet Homopolar Inductor Machine
A permanent magnet homopolar inductor machine (PMHIM) can operate at extremely high speeds due to its simple and robust rotor. However, the reliability of the machine at high speeds would be seriously affected by electromagnetic vibration. Aiming at this problem, the electromagnetic vibration mechanism of PMHIM and its suppression methods are studied in this article. First, the unilateral air gap electromagnetic force density (EFD) of PMHIM is established. The odd-order component of the specific permeability function causes the (2 k -1)* p -order EFD harmonics to be generated in the unilateral air gap. Second, staggered-rotor (S-R) and trapezoidal rotor (T-R) are proposed to suppress the EFD harmonics. Only the zero-order vibration harmonics (ZOVHs) can be suppressed by S-R. Both ZOVHs and pole-frequency harmonics can be suppressed by T-R. Third, the influence of S-R and T-R on the performance of PMHIM is comprehensively studied based on the finite element analysis. Finally, the effectiveness of the proposed rotors for suppressing vibration is verified by experiments. The results show that both the proposed S-R and T-R can effectively suppress the vibration, which further promotes the application of PMHIM in high-speed fields.
- 12 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 72 (1) , 155-166
Investigation and Suppression of Electromagnetic Vibration of Permanent Magnet Homopolar Inductor Machine
A permanent magnet homopolar inductor machine (PMHIM) can operate at extremely high speeds due to its simple and robust rotor. However, the reliability of the machine at high speeds would be seriously affected by electromagnetic vibration. Aiming at this problem, the electromagnetic vibration mechanism of PMHIM and its suppression methods are studied in this article. First, the unilateral air gap electromagnetic force density (EFD) of PMHIM is established. The odd-order component of the specific permeability function causes the (2 k -1)* p -order EFD harmonics to be generated in the unilateral air gap. Second, staggered-rotor (S-R) and trapezoidal rotor (T-R) are proposed to suppress the EFD harmonics. Only the zero-order vibration harmonics (ZOVHs) can be suppressed by S-R. Both ZOVHs and pole-frequency harmonics can be suppressed by T-R. Third, the influence of S-R and T-R on the performance of PMHIM is comprehensively studied based on the finite element analysis. Finally, the effectiveness of the proposed rotors for suppressing vibration is verified by experiments. The results show that both the proposed S-R and T-R can effectively suppress the vibration, which further promotes the application of PMHIM in high-speed fields.
- 11 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 60 (9) , 1-6
Influence of Stator Core Manufacturing Displacement on the Electromagnetic Performance of Modular Permanent Magnet Machine
This paper investigates the influence of manufacturing tolerances of modular stator core, including radial, circumferential and axial displacements, on the electromagnetic performance of a modular permanent magnet machine. First, the analytical analysis of no-load back electromotive force, circulating current, cogging torque and unbalanced magnetic force is derived. Second, several typical cases are selected to investigate the effects of the three displacement faults. Then, the effects of a single module under the same displacement amplitude fault are compared, and the results reveal the tolerance of electromagnetic performance to different displacements. Finally, references for the design, processing and manufacturing of modular motors are provided by the analysis results of this paper.
- 11 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 60 (9) , 1-6
Influence of Stator Core Manufacturing Displacement on the Electromagnetic Performance of Modular Permanent Magnet Machine
This paper investigates the influence of manufacturing tolerances of modular stator core, including radial, circumferential and axial displacements, on the electromagnetic performance of a modular permanent magnet machine. First, the analytical analysis of no-load back electromotive force, circulating current, cogging torque and unbalanced magnetic force is derived. Second, several typical cases are selected to investigate the effects of the three displacement faults. Then, the effects of a single module under the same displacement amplitude fault are compared, and the results reveal the tolerance of electromagnetic performance to different displacements. Finally, references for the design, processing and manufacturing of modular motors are provided by the analysis results of this paper.