Reply to Dr. Cold
- 22 April 2026
- journal article
- letter
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 58 (05) , 570-571
Abstract
10.1055/a-2797-9187 We thank Dr. Cold for the constructive comments on our recent paper [1] and agree that inspection-weighted metrics, such as effective withdrawal time [2], might correlate more directly with clinically meaningful outcomes than withdrawal time alone. Withdrawal time itself is therefore an imperfect surrogate for quality of inspection, although it is known to be closely related to the adenoma detection rate [3]. Furthermore, European Society of Gastrointestinal Endoscopy guidelines [4] include withdrawal time as a required performance measure in colonoscopy and recommend its routine measurement and documentation as part of the endoscopy report. Therefore, monitoring withdrawal time is undoubtedly a fixed point in endoscopic colorectal cancer screening. Our work evaluated an artificial intelligence (AI)-based system that calculates withdrawal time during the examination and provides the technical basis for automated report generation. Our goal was to evaluate the performance of such an AI system in real clinical practice, focusing on potential workflow automation rather than positioning withdrawal time as a quality surrogate. Given that documentation of withdrawal time is mandatory for colorectal cancer screening examinations, automation of its calculation and reporting represents a pragmatic approach to reducing cognitive load during withdrawal and decreasing documentation burden. Accordingly, although our work does not focus on associating withdrawal time estimation with clinical outcomes, the utilization and extension of the proposed approach may contribute to improved physician well-being and workflow efficiency, which in turn can support high-quality care delivery. Furthermore, the presented platform is modular and could host additional computer-assisted quality metrics, such as effective withdrawal time, allowing these inspection-weighted measures to be directly integrated into the examination report. Article published online: 22 April 2026 © 2026. Thieme. All rights reserved. Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, GermanyKeywords
This publication has 4 references indexed in Scilit:
- A prospective study evaluating an artificial intelligence-based system for withdrawal time measurementEndoscopy, 2025
- Artificial intelligence–assisted real-time monitoring of effective withdrawal time during colonoscopy: a novel quality marker of colonoscopyGastrointestinal Endoscopy, 2023
- Impact of withdrawal time on adenoma detection rate: results from a prospective multicenter trialGastrointestinal Endoscopy, 2022
- Performance measures for lower gastrointestinal endoscopy: a European Society of Gastrointestinal Endoscopy (ESGE) quality improvement initiativeUnited European Gastroenterology Journal, 2017