IKIoannis Kafetzis

Ioannis Kafetzis

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ioannis Kafetzis has a total of 51 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Evaluation of the OPTESK VR training simulator for gastric bleeding treatment

    by Annika Köhler, Irshath Ali Syed, Jana Sophia Theile, Ioannis Kafetzis, Joel Troya, Jan-Peter Grunz, Ulrike W. Denzer, Ivica Grgic, Benjamin M. Walter, Rüdiger Pryss, et al.

    Background: Bleeding in the upper gastrointestinal tract is a common and potentially life-threatening emergency that requires rapid and highly precise endoscopic intervention. As supervised hands-on training is limited and often restricted to living animal models, an immersive virtual reality (VR) simulation offers a risk-free and accessible alternative. Methods: A novel open-source VR training simulator, OPTESK, was developed for the treatment of upper gastrointestinal (GI) bleeding. The system consists of a combination of conventional endoscopes used in routine clinical practice, which can be operated in conjunction with commercially available head-mounted displays and the in-house developed OPTESK hardware. The simulator covers two scenarios: the treatment of a non-bleeding angiodysplasia with argon plasma coagulation (APC) and the treatment of a bleeding angiodysplasia starting with the injection of adrenaline followed by APC therapy. The simulator was evaluated in a multicenter user study in terms of workload, usability, immersion, cybersickness, and face, content, and construct validity. User performance was assessed via scores on time, amount of treated area, and correctly applied APC intensity. Results: In total, 44 participants from more than 20 centers were included in the study. Successful hemostatic control in the second scenario was achieved by 97.4% of the participants. Regarding the content validity, participants rated the helpfulness of the simulator for training the management of bleeding with a median of 4 on a scale from 1 (strongly disagree) to 5 (strongly agree). Mean perceived workload (NASA-TLX) and usability (SUS) were rated with 34.2/100 and 69.6/100 respectively. Face validity questions regarding the realism of endoscope movement, stomach anatomy, and application of APC were further rated with a median of 4 on the scale from 1 to 5. Regarding construct validity, gastroscopy experience showed significantly faster treatment of bleeding related tasks for both scenario one ( p = .008) and two ( p = .011) compared to participants with less gastroscopy experience. Conclusions: OPTESK can serve as a valuable training tool for endoscopic treatment of bleeding in the upper GI tract. This approach may help reduce dependence on animal-based training and enable risk-free practice prior to clinical intervention.

  • Open Access

    Artificial Intelligence‐Based Detection of Colonic Angiodysplasia Can Improve Endoscopic Reporting Consistency

    by Ioannis Kafetzis, Jana Sophia Theile, Stavros Dimitriadis, Jörg Albert, Wolfram Zoller, Alexander Meining, Alexander Hann

    Background and Study Aims: Colonic angiodysplasia (AD) is often found incidentally during colonoscopy and frequently omitted from reports, despite being a key cause of lower gastrointestinal bleeding. Artificial intelligence (AI) may improve reporting completeness. In this study, we developed and validated an AI system to support AD documentation. Methods: The system combines a computer vision (CV) model to detect AD in colonoscopy images and videos with a locally deployed open‐weight Large Language Model (LLM) to assess whether AD is mentioned in reports. It was externally validated on independent image datasets and prospectively collected videos and used to identify unreported AD cases. Results: The CV model was trained on 10,908 annotated images (986 with AD) from 993 colonoscopies. External validation of 3534 images from 239 procedures showed 94.5% accuracy, 84.4% sensitivity, and 95.9% specificity. The LLM detected AD documentation with 95.8% accuracy, 97.7% sensitivity, and 92.4% specificity. The combined system identified 88 cases where AD was visible but unreported. In 126 full‐length videos, 5 cases were physician‐reported, while the system detected 23 AD‐positive cases. Conclusions: Our AI system accurately detects AD and cross‐checks reports, improving documentation completeness and supporting standardized reporting while preserving privacy through local deployment.

  • Reply to Dr. Cold

    by Ioannis Kafetzis, Alexander Hann

    10.1055/a-2797-9187 We thank Dr. Cold for the constructive comments on our recent paper [1] and agree that inspection-weighted metrics, such as effective withdrawal time [2], might correlate more directly with clinically meaningful outcomes than withdrawal time alone. Withdrawal time itself is therefore an imperfect surrogate for quality of inspection, although it is known to be closely related to the adenoma detection rate [3]. Furthermore, European Society of Gastrointestinal Endoscopy guidelines [4] include withdrawal time as a required performance measure in colonoscopy and recommend its routine measurement and documentation as part of the endoscopy report. Therefore, monitoring withdrawal time is undoubtedly a fixed point in endoscopic colorectal cancer screening. Our work evaluated an artificial intelligence (AI)-based system that calculates withdrawal time during the examination and provides the technical basis for automated report generation. Our goal was to evaluate the performance of such an AI system in real clinical practice, focusing on potential workflow automation rather than positioning withdrawal time as a quality surrogate. Given that documentation of withdrawal time is mandatory for colorectal cancer screening examinations, automation of its calculation and reporting represents a pragmatic approach to reducing cognitive load during withdrawal and decreasing documentation burden. Accordingly, although our work does not focus on associating withdrawal time estimation with clinical outcomes, the utilization and extension of the proposed approach may contribute to improved physician well-being and workflow efficiency, which in turn can support high-quality care delivery. Furthermore, the presented platform is modular and could host additional computer-assisted quality metrics, such as effective withdrawal time, allowing these inspection-weighted measures to be directly integrated into the examination report. Article published online: 22 April 2026 © 2026. Thieme. All rights reserved. Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany

  • Open Access

    Artificial Intelligence–Assisted Flexure and Landmark Identification Improves Reporting Completeness in Colonoscopy

    by Radu-Alexandru Vulpoi, Ioannis Kafetzis, Mihaela Luca, Adrian Ciobanu, Oana Bogdana Barboi, Cristian Gheorghe, Eugen Dumitru, Alexander Meining, Alexander Hann, Vasile Liviu Drug

    Introduction Colorectal cancer is a major global health concern, with colonoscopy as the gold standard for detection and prevention. Accurate localization of findings remains challenging, limiting reporting objectivity and completeness, which can be supported by artificial intelligence (AI). We present an AI system that identifies the appendiceal orifice, ileocecal valve, and flexures, enabling automated colon segment localization. Methods The AI was trained on 7264 manually annotated images from 991 patients and internally evaluated on 1238 images from 215 patients. Performance was assessed using accuracy, sensitivity, specificity, and F1-score. External validation was conducted on 78 public videos. The impact on standardized reporting was evaluated on 14 videos recorded in a different external clinic that did not contribute training data. These were independently evaluated by two expert endoscopists who reached a consensus that was used as the gold standard for flexure detection. Results On the internal image test set, the AI achieved 94.5% accuracy, 76.7% sensitivity, 97.0% specificity, and 0.79 F1-score. In external validation on videos from a public dataset, the AI identified 91.7% of cecum segments and 66% of flexures, with 81.4% detected within 30 s of annotation. AI integration improved flexure identification in the external video dataset from the second clinic, increasing detected flexures by 53.8% and videos with both flexures identified by 133.3%. Conclusions The AI reliably detects key anatomical landmarks, supporting colon segment localization. Its integration into reporting pipelines could enhance lesion localization, improve report completeness, and reduce documentation workload.

  • Open Access

    Assessing realism of artificial intelligence-generated colorectal polyp images: International multicenter blinded reader study

    by Philipp Sodmann, Ronja Weber, Valentin Wettstein, Ioannis Kafetzis, Yun Chiang, Venkatesh Parayitam, Michela Pauletti, Konstantinos Kouladouros, Alexander Meining, Alexander Hann

    Prevention of colorectal cancer relies on detection and characterization of polyps during colonoscopy, yet access to large, shareable training datasets is limited. To address this issue, we developed a diffusion-based artificial intelligence (AI) model to generate synthetic polyp images in high-resolution and assessed their perceived realism in an international blinded reader study. Fifty-three endoscopists from 46 centers across 14 countries evaluated 20 real and 20 AI-generated images in random order using our web platform Lutetia. Experts classified the images as either real or synthetic and rated their confidence. The primary endpoint was sensitivity of identifying synthetic images. Secondary endpoints were recognition of real images and overall accuracy. The trial was registered at clinicaltrials.gov with the identifier NCT07108569. Sensitivity for detecting AI-generated images was 66% (95% confidence interval [CI] 65%-67%) with a specificity of 80% (95% CI 79%-81%); overall accuracy was 73% (95% CI 72%-73%). Low-confidence decisions were more frequent for AI-generated images and associated with longer annotation time (P < 0.001). Difficulties in differentiating synthetic from real images together with lower confidence and longer decision times shows that our diffusion model generates highly realistic polyp images.

  • Open Access

    Advancing artificial intelligence applicability in endoscopy through source-agnostic camera signal extraction from endoscopic images

    by Ioannis Kafetzis, Philipp Sodmann, Robert Hüneburg, Jacob Nattermann, Nora Martens, Daniel R. Englmann, Wolfram G. Zoller, Alexander Meining, Alexander Hann

    Introduction: Successful application of artificial intelligence (AI) in endoscopy requires effective image processing. Yet, the plethora of sources for endoscopic images, such as different processor-endoscope combinations or capsule endoscopy devices, results in images that vastly differ in appearance. These differences hinder the generalizability of AI models in endoscopy. Methods: We developed an AI-based method for extracting the camera signal from raw endoscopic images in a source-agnostic manner. Additionally, we created a diverse dataset of standardized endoscopic images, named Endoscopic Processor Image Collection (EPIC), from 4 different endoscopy centers. Included data were recorded using 9 different processors from 4 manufacturers with 45 endoscopes. Furthermore, images recorded with 4 capsule endoscopy devices from 2 manufacturers are included. We evaluated the camera signal extraction method using 641 manually annotated images from 5 different, publicly available endoscopic image datasets, as well as on the EPIC dataset. Results were compared it with a published baseline in terms of Intersection over Union (IoU) and Hausdorff distance (HD). Results: In segmenting the camera signal on images from public datasets, our method achieved mean IoU of 0.97 which was significantly higher than that of the baseline method and mean HD of 21 pixels which was significantly lower compared to the baseline. On the standardized images of the EPIC dataset, there was no significant difference between IoU but our method achieved a significantly lower HD. Both the developed AI-based method and the generated dataset are made publicly available. Conclusion: This work introduces an AI-based method that effectively segments the endoscope camera signal from the raw endoscopic data in a source-agnostic way. Utilizing the proposed method as a preprocessing step allows existing AI models to use any endoscopic image, independent of its source, without compromising performance. Additionally, EPIC, a dataset of diverse endoscopic images, is generated. The proposed method, trained AI model weights, and the EPIC dataset are made publicly available.


  • Open Access

    Hiatal Hernias Revisited—A Systematic Review of Definitions, Classifications, and Applications

    by Karl Hermann Fuchs, Ioannis Kafetzis, Alexander Hann, Alexander Meining

    Introduction: A hiatal hernia (HH) can be defined as a condition in which elements from the abdominal cavity herniate through the oesophageal hiatus in the mediastinum and, in the majority of cases, parts of the proximal stomach. Today, the role of HHs within the complex entity of gastroesophageal reflux disease (GERD) is very important with regard to its pathophysiology, severity, and therapeutic and prognostic options. Despite this, the application and stringent use of the worldwide accepted classification (Skinner and Belsey: Types I–IV) are lacking. The aim of this study was to carry out a systematic review of the clinical applications of HH classifications and scientific documentation over time, considering their value in diagnosis and treatment. Methods: Following the PRISMA concept, all abstracts published on pubmed.gov until 12/2023 (hiatal hernia) were reviewed, and those with a focus and clear description of the application of the current HH classification in the full-text version were analysed to determine the level of classification and its use within the therapeutic context. Results: In total, 9342 abstracts were screened. In 9199 of the abstracts, the reports had a different focus than HH, or the HH classification was not used or was incompletely applied. After further investigation, 60 papers were used for a detailed analysis, which included more than 12,000 patient datapoints. Among the 8904 patients, 83% had a Type I HH; 4% had Type II; 11% had Type III; and 1% had Type IV. Further subgroup analyses were performed. Overall, the precise application of the HH classification has been insufficient, considering that only 1% of all papers and only 54% of those with a special focus on HH have documented its use. Conclusions: The application and documentation of a precise HH classification in clinical practice and scientific reports are decreasing, which should be rectified for the purpose of scientific comparability.


  • Open Access

    Efficient artificial intelligence-based assessment of the gastroesophageal valve with Hill classification through active learning

    by Ioannis Kafetzis, Karl-Hermann Fuchs, Philipp Sodmann, Joel Troya, Wolfram Zoller, Alexander Meining, Alexander Hann

    Standardized assessment of the gastroesophageal valve during endoscopy, attainable via the Hill classification, is important for clinical assessment and therapeutic decision making. The Hill classification is associated with the presence of hiatal hernia (HH), a common endoscopic finding connected to gastro-esophageal reflux disease. A novel efficient medical artificial intelligence (AI) training pipeline using active learning (AL) is designed. We identified 21,970 gastroscopic images as training data and used our AL to train a model for predicting the Hill classification and detecting HH. Performance of the AL and traditionally trained models were evaluated on an external expert-annotated image collection. The AL model achieved accuracy of 76%. A traditionally trained model with 125% more training data achieved 77% accuracy. Furthermore, the AL model achieved higher precision than the traditional one for rare classes, with 0.54 versus 0.39 (p < 0.05) for grade 3 and 0.72 versus 0.61 (p < 0.05) for grade 4. In detecting HH, the AL model achieved 94% accuracy, 0.72 precision and 0.74 recall. Our AL pipeline is more efficient than traditional methods in training AI for endoscopy.


  • On the Stabilization of Singular, Strictly Proper Transfer Function Matrices

    by Ioannis Kafetzis, Nicholas Karampetakis

    This work focuses on the computation of stabilizing controllers for singular transfer function matrices. Stabilization of systems is a thoroughly studied subject, and numerous methodologies that enable the determination of stabilizing controllers have been developed over the years. In this work, we present a framework that unifies these methodologies. More explicitly, we utilize equivalence relations of rational matrices, allowing us to reduce the problem of stabilizing a singular transfer function to the problem of stabilizing a nonsingular transfer function matrix of smaller dimensions, thus connecting the stabilization of singular and nonsingular MIMO transfer functions. Furthermore, it is shown that the aforementioned nonsingular matrix can always be diagonal, in which case the problem of stabilizing it is reduced to stabilizing each of its diagonal elements, which are SISO transfer functions. Finally, it is proved that using this equivalence relation, similar results hold for the case of strong stabilizing controllers, that is, stabilizing controllers that are stable themselves.

  • Open Access

    Chaotification of 1D Maps by Multiple Remainder Operator Additions—Application to B-Spline Curve Encryption

    by Lazaros Moysis, Marcin Lawnik, Ioannis P. Antoniades, Ioannis Kafetzis, Murilo S. Baptista, Christos Volos

    In this work, a chaotification technique is proposed for increasing the complexity of chaotic maps. The technique consists of adding the remainder of multiple scalings of the map’s value for the next iteration, so that the most- and least-significant digits are combined. By appropriate parameter tuning, the resulting map can achieve a higher Lyapunov exponent value, a result that was first proven theoretically and then showcased through numerical simulations for a collection of chaotic maps. As a proposed application of the transformed maps, the encryption of B-spline curves and patches was considered. The symmetric encryption consisted of two steps: a shuffling of the control point coordinates and an additive modulation. A transformed chaotic map was utilised to perform both steps. The resulting ciphertext curves and patches were visually unrecognisable compared to the plaintext ones and performed well on several statistical tests. The proposed work gives an insight into the potential of the remainder operator for chaotification, as well as the chaos-based encryption of curves and computer graphics.