Impact of the NTCP modeling on medical decision to select eligible patient for proton therapy: the usefulness of EUD as an indicator to rank modern photon vs proton treatment plans
Open Access
- 16 July 2018
- journal article
- research article
- Published by Taylor & Francis in International Journal of Radiation Biology
- Vol. 94 (9) , 789-797
Abstract
Purpose: The aim of this study is to evaluate the impact of normal tissue complication probability (NTCP)-based radiobiological models on the estimated risk for late radiation lung damages. The second goal is to propose a medical decision-making approach to select the eligible patient for particle therapy. Materials and methods: Fourteen pediatric patients undergoing cranio-spinal irradiation were evaluated. For each patient, two treatment plans were generated using photon and proton therapy with the same dose prescriptions. Late radiation damage to lung was estimated using three NTCP concepts: the Lyman-Kutcher-Burman, the equivalent uniform dose (EUD) and the mean lung dose according to the quantitative analysis of normal tissue effects in the clinic QUANTEC review. Wilcoxon paired test was used to calculate p-value. Results: Proton therapy achieved lower lung EUD (Gy). The average NTCP values were significantly lower with proton plans, p < .05, using the three NTCP concepts. However, applying the same TD50/5 using radiobiological models to compare NTCP from proton and photon therapy, the ΔNTCP was not a convincing method to measure the potential benefit of proton therapy. Late radiation pneumonitis estimated from the mean lung dose model correlated with QUANTEC data better. Conclusions: Treatment effectiveness assessed on NTCP reduction depends on radiobiological predictions and parameters used as inputs for in silico evaluation. Because estimates of absolute NTCP values from LKB and GN models are imprecise due to EUD ≪ TD50/5, a reduction of the EUD value with proton plans would better predict a reduction of dose/toxicity. The EUD concept appears as a robust radiobiological surrogate of the dose distribution to select the optimal patient’s plan.Keywords
Funding Information
- French Research Funding Agency; Agence Nationale de la Recherche (ANR-11-INBS-)
This publication has 30 references indexed in Scilit:
- Low LET protons focused to submicrometer shows enhanced radiobiological effectivenessPhysics in Medicine & Biology, 2012
- Radiobiological risk estimates of adverse events and secondary cancer for proton and photon radiation therapy of pediatric medulloblastomaActa Oncologica, 2011
- Use of Normal Tissue Complication Probability Models in the ClinicInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2010
- Radiation Dose–Volume Effects in the LungInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2010
- Irradiation of Varying Volumes of Rat Lung to Same Mean Lung Dose: a Little to a Lot or a Lot to a Little?International Journal of Radiation Oncology - Biology - Physics (IJROBP), 2008
- Early clinical and radiological pulmonary complications following breast cancer radiation therapy: NTCP fit with four different modelsRadiotherapy and Oncology, 2007
- NTCP modelling and pulmonary function tests evaluation for the prediction of radiation induced pneumonitis in non-small-cell lung cancer radiotherapyPhysics in Medicine & Biology, 2007
- Comparing different NTCP models that predict the incidence of radiation pneumonitisInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2003
- Calculation of complication probability factors for non-uniform normal tissue irradiation: The effective volume method geraldInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1989
- Complication Probability as Assessed from Dose-Volume HistogramsRadiation Research, 1985