Abdulhamid Chaikh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Abdulhamid Chaikh has a total of 78 co-authors. Here are the top co-authors by number of shared publications:
Jacques Balosso
Univ Hosp Grenoble Alpes, Dept Cancerol Radiotherapy, Grenoble, France
22 shared publicationsJ. Balosso
ARCHADE, Advanced Resource Center for HADrontherapy in Europe, Caen, France; Service de radiothérapie et physique médicale, centre François-Baclesse, Caen, France; University Grenoble-Alpes et CHU Grenoble-Alpes, Grenoble, France
12 shared publications- Juliette Thariat
UMR6534, École Nationale Supérieure d'Ingénieurs de Caen, Caen, France, France
6 shared publications - Jean-Yves Giraud
Service de Radiothérapie, Centre Hospitalier Universitaire Grenoble Alpes, Université Grenoble Alpes, 38043 Grenoble, France
5 shared publications - Jacques Balosso
Department of Radiation Oncology, Centre Francois Baclesse, 14000 Caen, France
4 shared publications Jean-Yves Giraud
Univ Hosp Grenoble Alpes, Dept Cancerol Radiotherapy, Grenoble, France
3 shared publications
Latest Publications
- 30 March 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Méthodologie d'évaluation des impacts cliniques et dosimétriques d'un changement de procédure en radiothérapie : Aspect - Radio physique et médical
Introduction et objectif : La prescription des traitements en radiothérapie est basée sur l'analyse de la répartition de dose calculée par le TPS. Un changement d'algorithme de calcul doit être précédé d'une analyse dosimétrique complète, afin que les impacts cliniques soient maitrisés. Nous présentons une méthodologie de mise en œuvre d'un nouveau TPS. Matériel et méthodologie : Nous avons utilisé 5 algorithmes de calcul de dose. Nous avons comparé 6 plans de traitement avec des configurations identiques : patient, énergie, balistique. Nous avons comparé 12 localisations tumorales : 5 poumons, 1 œsophage, 1 sein, 3 ORL, 1 encéphales et 1 prostate. Le principe de méthodologie est basé sur deux critères d'analyse : 1.Critère d'analyse dosimétrique : nous avons classé les outils d'analyse en 3 catégories : analyse liée à la dose de traitement, analyse liée à la distribution de dose et analyse liée à la répartition de la dose 2.Critère d'analyse statistique : nous avons considéré que nous avons 5 séries de mesure liée à 5 algorithmes. Nous avons considéré les valeurs dosimétriques calculées par l'ancien algorithme comme valeurs de référence. Le test de comparaison statistique utilisé était un Wilcoxon pour série apparié avec un seuil de signification de 5% et un intervalle de confiance à 95%. Résultats et discussion : Nous avons trouvé des écarts pour tous les paramètres comparés dans cette étude. Ces écarts dépendent de la localisation de la tumeur et de l'algorithme de calcul. La maîtrise statistique des résultats nous permet, d'une part de diagnostiquer et interpréter les écarts dosimétriques observés et d'autre part, de déterminer si les écarts sont significatifs. Conclusion : Nous proposons une méthodologie qui permet de quantifier d'éventuels écarts dosimétriques lors d'un changement d'algorithme. L'analyse statistique permet de s'assurer que les résultats sont significatifs.
- 30 March 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Méthodologie d'évaluation des impacts cliniques et dosimétriques d'un changement de procédure en radiothérapie : Aspect - Radio physique et médical
Introduction et objectif : La prescription des traitements en radiothérapie est basée sur l'analyse de la répartition de dose calculée par le TPS. Un changement d'algorithme de calcul doit être précédé d'une analyse dosimétrique complète, afin que les impacts cliniques soient maitrisés. Nous présentons une méthodologie de mise en œuvre d'un nouveau TPS. Matériel et méthodologie : Nous avons utilisé 5 algorithmes de calcul de dose. Nous avons comparé 6 plans de traitement avec des configurations identiques : patient, énergie, balistique. Nous avons comparé 12 localisations tumorales : 5 poumons, 1 œsophage, 1 sein, 3 ORL, 1 encéphales et 1 prostate. Le principe de méthodologie est basé sur deux critères d'analyse : 1.Critère d'analyse dosimétrique : nous avons classé les outils d'analyse en 3 catégories : analyse liée à la dose de traitement, analyse liée à la distribution de dose et analyse liée à la répartition de la dose 2.Critère d'analyse statistique : nous avons considéré que nous avons 5 séries de mesure liée à 5 algorithmes. Nous avons considéré les valeurs dosimétriques calculées par l'ancien algorithme comme valeurs de référence. Le test de comparaison statistique utilisé était un Wilcoxon pour série apparié avec un seuil de signification de 5% et un intervalle de confiance à 95%. Résultats et discussion : Nous avons trouvé des écarts pour tous les paramètres comparés dans cette étude. Ces écarts dépendent de la localisation de la tumeur et de l'algorithme de calcul. La maîtrise statistique des résultats nous permet, d'une part de diagnostiquer et interpréter les écarts dosimétriques observés et d'autre part, de déterminer si les écarts sont significatifs. Conclusion : Nous proposons une méthodologie qui permet de quantifier d'éventuels écarts dosimétriques lors d'un changement d'algorithme. L'analyse statistique permet de s'assurer que les résultats sont significatifs.
- Open Access
- 1 August 2021
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 11 (8) , 3481-3493
Doses delivered by portal imaging quality assurance in routine practice of adjuvant breast radiotherapy worth to by monitored and compensated in some cases
Background: Imaging, in radiotherapy, has become a routine tool for repositioning of the target volume at each session. The repositioning precision, currently infracentimetric, evolves along with the irradiation techniques. This retrospective study aimed to identify practices and doses resulting from the use of high energy planar imaging (portal imaging) in daily practice. Methods: A retrospective survey of portal images (PIs) was carried out over 10 years for 2,403 patients and for three linacs (1 Elekta SLi, 2 Varian Clinac) for postoperative mammary irradiations. Images were taken using a standardized number of monitor units (MU) for all patients. Due to the variable sensitivities of the detectors and the possibility of adjustment of the detector-patient distance, the number of MU were 3; 2 and 1 respectively, for Elekta SLi®, Clinac 600® and Clinac 2100®. Then, a representative cumulated dose was calculated in simplified reference conditions (5 cm depth, beam of 10 cm × 10 cm, 6 MV), considering the total number of images taken during the whole treatment course. The consistency between the representative doses and the actual absorbed doses received by the patients was verified by simulating a series of typical cases with the treatment plan dose calculation system. Results: The delivered doses differ significantly between the three linacs. The mean representative dose values by complete treatment were 0.695; 0.241 and 0.216 Gy, respectively, for SLi, Clinac 600 and Clinac 2100. However, 15 patients were exposed to a dose >2 Gy with a maximum dose of 5.05 Gy. The simulated doses were very similar to the representative doses. Conclusions: A significant dose delivery was highlighted by this study. These representative doses are presently communicated weekly to the radiation oncologist for the radiation protection of their patients. Moreover, they should be taken into account in a possible study of long-term stochastic risks.
- 1 August 2021
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 11 (8) , 3481-3493
Open AccessDoses delivered by portal imaging quality assurance in routine practice of adjuvant breast radiotherapy worth to by monitored and compensated in some cases
Background: Imaging, in radiotherapy, has become a routine tool for repositioning of the target volume at each session. The repositioning precision, currently infracentimetric, evolves along with the irradiation techniques. This retrospective study aimed to identify practices and doses resulting from the use of high energy planar imaging (portal imaging) in daily practice. Methods: A retrospective survey of portal images (PIs) was carried out over 10 years for 2,403 patients and for three linacs (1 Elekta SLi, 2 Varian Clinac) for postoperative mammary irradiations. Images were taken using a standardized number of monitor units (MU) for all patients. Due to the variable sensitivities of the detectors and the possibility of adjustment of the detector-patient distance, the number of MU were 3; 2 and 1 respectively, for Elekta SLi®, Clinac 600® and Clinac 2100®. Then, a representative cumulated dose was calculated in simplified reference conditions (5 cm depth, beam of 10 cm × 10 cm, 6 MV), considering the total number of images taken during the whole treatment course. The consistency between the representative doses and the actual absorbed doses received by the patients was verified by simulating a series of typical cases with the treatment plan dose calculation system. Results: The delivered doses differ significantly between the three linacs. The mean representative dose values by complete treatment were 0.695; 0.241 and 0.216 Gy, respectively, for SLi, Clinac 600 and Clinac 2100. However, 15 patients were exposed to a dose >2 Gy with a maximum dose of 5.05 Gy. The simulated doses were very similar to the representative doses. Conclusions: A significant dose delivery was highlighted by this study. These representative doses are presently communicated weekly to the radiation oncologist for the radiation protection of their patients. Moreover, they should be taken into account in a possible study of long-term stochastic risks.
- 1 August 2018
- Published by Elsevier in Physica Medica
- Vol. 52, 174
[P259] Radiobiological method for the clinical validation of models dose-to-water versus dose-to-meduim in radiotherapy
- 1 August 2018
- Published by Elsevier in Physica Medica
- Vol. 52, 174
[P259] Radiobiological method for the clinical validation of models dose-to-water versus dose-to-meduim in radiotherapy
- Open Access
- 16 July 2018
- Published by Taylor & Francis in International Journal of Radiation Biology
- Vol. 94 (9) , 789-797
Impact of the NTCP modeling on medical decision to select eligible patient for proton therapy: the usefulness of EUD as an indicator to rank modern photon vs proton treatment plans
Purpose: The aim of this study is to evaluate the impact of normal tissue complication probability (NTCP)-based radiobiological models on the estimated risk for late radiation lung damages. The second goal is to propose a medical decision-making approach to select the eligible patient for particle therapy. Materials and methods: Fourteen pediatric patients undergoing cranio-spinal irradiation were evaluated. For each patient, two treatment plans were generated using photon and proton therapy with the same dose prescriptions. Late radiation damage to lung was estimated using three NTCP concepts: the Lyman-Kutcher-Burman, the equivalent uniform dose (EUD) and the mean lung dose according to the quantitative analysis of normal tissue effects in the clinic QUANTEC review. Wilcoxon paired test was used to calculate p-value. Results: Proton therapy achieved lower lung EUD (Gy). The average NTCP values were significantly lower with proton plans, p < .05, using the three NTCP concepts. However, applying the same TD50/5 using radiobiological models to compare NTCP from proton and photon therapy, the ΔNTCP was not a convincing method to measure the potential benefit of proton therapy. Late radiation pneumonitis estimated from the mean lung dose model correlated with QUANTEC data better. Conclusions: Treatment effectiveness assessed on NTCP reduction depends on radiobiological predictions and parameters used as inputs for in silico evaluation. Because estimates of absolute NTCP values from LKB and GN models are imprecise due to EUD ≪ TD50/5, a reduction of the EUD value with proton plans would better predict a reduction of dose/toxicity. The EUD concept appears as a robust radiobiological surrogate of the dose distribution to select the optimal patient’s plan.
- 16 July 2018
- Published by Taylor & Francis in International Journal of Radiation Biology
- Vol. 94 (9) , 789-797
Open AccessImpact of the NTCP modeling on medical decision to select eligible patient for proton therapy: the usefulness of EUD as an indicator to rank modern photon vs proton treatment plans
Purpose: The aim of this study is to evaluate the impact of normal tissue complication probability (NTCP)-based radiobiological models on the estimated risk for late radiation lung damages. The second goal is to propose a medical decision-making approach to select the eligible patient for particle therapy. Materials and methods: Fourteen pediatric patients undergoing cranio-spinal irradiation were evaluated. For each patient, two treatment plans were generated using photon and proton therapy with the same dose prescriptions. Late radiation damage to lung was estimated using three NTCP concepts: the Lyman-Kutcher-Burman, the equivalent uniform dose (EUD) and the mean lung dose according to the quantitative analysis of normal tissue effects in the clinic QUANTEC review. Wilcoxon paired test was used to calculate p-value. Results: Proton therapy achieved lower lung EUD (Gy). The average NTCP values were significantly lower with proton plans, p < .05, using the three NTCP concepts. However, applying the same TD50/5 using radiobiological models to compare NTCP from proton and photon therapy, the ΔNTCP was not a convincing method to measure the potential benefit of proton therapy. Late radiation pneumonitis estimated from the mean lung dose model correlated with QUANTEC data better. Conclusions: Treatment effectiveness assessed on NTCP reduction depends on radiobiological predictions and parameters used as inputs for in silico evaluation. Because estimates of absolute NTCP values from LKB and GN models are imprecise due to EUD ≪ TD50/5, a reduction of the EUD value with proton plans would better predict a reduction of dose/toxicity. The EUD concept appears as a robust radiobiological surrogate of the dose distribution to select the optimal patient’s plan.
- 11 May 2018
- Published by Taylor & Francis
- p. 145-154
Normal Tissue Complication Probability Reduction in Advanced Head and Neck Cancer Patients Using Proton Therapy
Head and neck squamous cell carcinoma (HNSCC), perhaps more than other cancer types, poses the problem of the benefit-risk balance. Indeed, these tumours are radio-curable, but at very high doses in an extremely functional anatomical environment, where early or late toxicity can have devastating effects on the quality of life (QOL). The need to increase as much as possible the therapeutic index leads to consider particle therapy, which offers greater dosimetric discrimination than photon therapy (Rayon X). Nevertheless, the high incidence of HNSCC (3%–5% of cancers) patients often living in poor conditions and the low availability of proton therapy (PT) centres have meant that, until recently, PT has been applied to treatment of head and neck (H&N) tumours that are not HNSCC. These are adenoid cystic carcinomas, chordomas, or sarcomas of the base of the skull, recurrent undifferentiated carcinoma of nasopharyngeal type (UCNT) or sinonasal tumours for which experience has been gained with PT, often as a boost with RX [1]. This initial experience reveals the possible severity of side effects, ranging from blindness to xerostomia and severe and lasting swallowing disorders. Severe toxicities have also been reported in exclusive PT series due to high-dose treatments of skull base tumours [1].
- 11 May 2018
- Published by Taylor & Francis
- p. 145-154
Normal Tissue Complication Probability Reduction in Advanced Head and Neck Cancer Patients Using Proton Therapy
Head and neck squamous cell carcinoma (HNSCC), perhaps more than other cancer types, poses the problem of the benefit-risk balance. Indeed, these tumours are radio-curable, but at very high doses in an extremely functional anatomical environment, where early or late toxicity can have devastating effects on the quality of life (QOL). The need to increase as much as possible the therapeutic index leads to consider particle therapy, which offers greater dosimetric discrimination than photon therapy (Rayon X). Nevertheless, the high incidence of HNSCC (3%–5% of cancers) patients often living in poor conditions and the low availability of proton therapy (PT) centres have meant that, until recently, PT has been applied to treatment of head and neck (H&N) tumours that are not HNSCC. These are adenoid cystic carcinomas, chordomas, or sarcomas of the base of the skull, recurrent undifferentiated carcinoma of nasopharyngeal type (UCNT) or sinonasal tumours for which experience has been gained with PT, often as a boost with RX [1]. This initial experience reveals the possible severity of side effects, ranging from blindness to xerostomia and severe and lasting swallowing disorders. Severe toxicities have also been reported in exclusive PT series due to high-dose treatments of skull base tumours [1].
- Open Access
- 3 April 2018
- Published by Springer Nature in Radiation Oncology
- Vol. 13 (1) , 60
Dosimetrical and radiobiological approach to manage the dosimetric shift in the transition of dose calculation algorithm in radiation oncology: how to improve high quality treatment and avoid unexpected outcomes?
For a given prescribed dose of radiotherapy, with the successive generations of dose calculation algorithms, more monitor units (MUs) are generally needed. This is due to the implementation of successive improvements in dose calculation: better heterogeneity correction and more accurate estimation of secondary electron transport contribution. More recently, there is the possibility to report the dose-to-medium, physically more accurate compared to the dose-to-water as the reference one. This last point is a recent concern and the main focus of this study. In this paper, we propose steps for a general analysis procedure to estimate the dosimetric alterations, and the potential clinical changes, between a reference algorithm and a new one. This includes dosimetric parameters, gamma index, radiobiology indices based on equivalent uniform dose concept and statistics with bootstrap simulation. Finally, we provide a general recommendation on the clinical use of new algorithms regarding the dose prescription or dose limits to the organs at risks. The dosimetrical and radiobiological data showed a significant effect, which might exceed 5–10%, of the calculation method on the dose the distribution and clinical outcomes for lung cancer patients. Wilcoxon signed rank paired comparisons indicated that the delivered dose in MUs was significantly increased (> 2%) using more advanced dose calculation methods as compared to the reference one. This paper illustrates and explains the use of dosimetrical, radiobiologcal and statistical tests for dosimetric comparisons in radiotherapy. The change of dose calculation algorithm may induce a dosimetric shift, which has to be evaluated by the physicists and the oncologists. This includes the impact on tumor control and on the risk of toxicity based on normal tissue dose constraints. In fact, the alteration in dose distribution makes it hard to keep exactly the same tumor control probability along with the same normal tissue complication probability.
- 3 April 2018
- Published by Springer Nature in Radiation Oncology
- Vol. 13 (1) , 60
Open AccessDosimetrical and radiobiological approach to manage the dosimetric shift in the transition of dose calculation algorithm in radiation oncology: how to improve high quality treatment and avoid unexpected outcomes?
For a given prescribed dose of radiotherapy, with the successive generations of dose calculation algorithms, more monitor units (MUs) are generally needed. This is due to the implementation of successive improvements in dose calculation: better heterogeneity correction and more accurate estimation of secondary electron transport contribution. More recently, there is the possibility to report the dose-to-medium, physically more accurate compared to the dose-to-water as the reference one. This last point is a recent concern and the main focus of this study. In this paper, we propose steps for a general analysis procedure to estimate the dosimetric alterations, and the potential clinical changes, between a reference algorithm and a new one. This includes dosimetric parameters, gamma index, radiobiology indices based on equivalent uniform dose concept and statistics with bootstrap simulation. Finally, we provide a general recommendation on the clinical use of new algorithms regarding the dose prescription or dose limits to the organs at risks. The dosimetrical and radiobiological data showed a significant effect, which might exceed 5–10%, of the calculation method on the dose the distribution and clinical outcomes for lung cancer patients. Wilcoxon signed rank paired comparisons indicated that the delivered dose in MUs was significantly increased (> 2%) using more advanced dose calculation methods as compared to the reference one. This paper illustrates and explains the use of dosimetrical, radiobiologcal and statistical tests for dosimetric comparisons in radiotherapy. The change of dose calculation algorithm may induce a dosimetric shift, which has to be evaluated by the physicists and the oncologists. This includes the impact on tumor control and on the risk of toxicity based on normal tissue dose constraints. In fact, the alteration in dose distribution makes it hard to keep exactly the same tumor control probability along with the same normal tissue complication probability.
- 1 March 2018
- Published by Elsevier in Bulletin du Cancer
- Vol. 105 (3) , 315-326
Apports de la protonthérapie à la radiothérapie d’aujourd’hui, pourquoi, comment ?
- 1 March 2018
- Published by Elsevier in Bulletin du Cancer
- Vol. 105 (3) , 315-326
Apports de la protonthérapie à la radiothérapie d’aujourd’hui, pourquoi, comment ?
- 1 February 2018
- Published by Elsevier in Cancer Treatment Reviews
- Vol. 63, 19-27
Proton therapy for locally advanced breast cancer: A systematic review of the literature
- 1 February 2018
- Published by Elsevier in Cancer Treatment Reviews
- Vol. 63, 19-27
Proton therapy for locally advanced breast cancer: A systematic review of the literature
- 1 June 2017
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 7 (3) , 292-298
Agreement between gamma passing rates using computed tomography in radiotherapy and secondary cancer risk prediction from more advanced dose calculated models
Background: During the past decades, in radiotherapy, the dose distributions were calculated using density correction methods with pencil beam as type ‘a’ algorithm. The objectives of this study are to assess and evaluate the impact of dose distribution shift on the predicted secondary cancer risk (SCR), using modern advanced dose calculation algorithms, point kernel, as type ‘b’, which consider change in lateral electrons transport. Methods: Clinical examples of pediatric cranio-spinal irradiation patients were evaluated. For each case, two radiotherapy treatment plans with were generated using the same prescribed dose to the target resulting in different number of monitor units (MUs) per field. The dose distributions were calculated, respectively, using both algorithms types. A gamma index (γ) analysis was used to compare dose distribution in the lung. The organ equivalent dose (OED) has been calculated with three different models, the linear, the linear-exponential and the plateau dose response curves. The excess absolute risk ratio (EAR) was also evaluated as (EAR = OED type ‘b’ / OED type ‘a’). Results: The γ analysis results indicated an acceptable dose distribution agreement of 95% with 3%/3 mm. Although, the γ-maps displayed dose displacement >1 mm around the healthy lungs. Compared to type ‘a’, the OED values from type ‘b’ dose distributions’ were about 8% to 16% higher, leading to an EAR ratio >1, ranged from 1.08 to 1.13 depending on SCR models. Conclusions: The shift of dose calculation in radiotherapy, according to the algorithm, can significantly influence the SCR prediction and the plan optimization, since OEDs are calculated from DVH for a specific treatment. The agreement between dose distribution and SCR prediction depends on dose response models and epidemiological data. In addition, the γ passing rates of 3%/3 mm does not translate the difference, up to 15%, in the predictions of SCR resulting from alternative algorithms. Considering that modern algorithms are more accurate, showing more precisely the dose distributions, but that the prediction of absolute SCR is still very imprecise, only the EAR ratio could be used to rank radiotherapy plans.
- 1 June 2017
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 7 (3) , 292-298
Agreement between gamma passing rates using computed tomography in radiotherapy and secondary cancer risk prediction from more advanced dose calculated models
Background: During the past decades, in radiotherapy, the dose distributions were calculated using density correction methods with pencil beam as type ‘a’ algorithm. The objectives of this study are to assess and evaluate the impact of dose distribution shift on the predicted secondary cancer risk (SCR), using modern advanced dose calculation algorithms, point kernel, as type ‘b’, which consider change in lateral electrons transport. Methods: Clinical examples of pediatric cranio-spinal irradiation patients were evaluated. For each case, two radiotherapy treatment plans with were generated using the same prescribed dose to the target resulting in different number of monitor units (MUs) per field. The dose distributions were calculated, respectively, using both algorithms types. A gamma index (γ) analysis was used to compare dose distribution in the lung. The organ equivalent dose (OED) has been calculated with three different models, the linear, the linear-exponential and the plateau dose response curves. The excess absolute risk ratio (EAR) was also evaluated as (EAR = OED type ‘b’ / OED type ‘a’). Results: The γ analysis results indicated an acceptable dose distribution agreement of 95% with 3%/3 mm. Although, the γ-maps displayed dose displacement >1 mm around the healthy lungs. Compared to type ‘a’, the OED values from type ‘b’ dose distributions’ were about 8% to 16% higher, leading to an EAR ratio >1, ranged from 1.08 to 1.13 depending on SCR models. Conclusions: The shift of dose calculation in radiotherapy, according to the algorithm, can significantly influence the SCR prediction and the plan optimization, since OEDs are calculated from DVH for a specific treatment. The agreement between dose distribution and SCR prediction depends on dose response models and epidemiological data. In addition, the γ passing rates of 3%/3 mm does not translate the difference, up to 15%, in the predictions of SCR resulting from alternative algorithms. Considering that modern algorithms are more accurate, showing more precisely the dose distributions, but that the prediction of absolute SCR is still very imprecise, only the EAR ratio could be used to rank radiotherapy plans.