Validity of 2 Skinfold Calipers in Estimating Percent Body Fat of College-Aged Men and Women
Authors:
- Jason R BeamJBJason R Beam
- David J SzymanskiDSDavid J Szymanski
- 1 December 2010
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Strength & Conditioning Research
- Vol. 24 (12) , 3448-3456
Abstract
There is a need for cost-effective techniques that accurately predict percent body fat (%BF) and require little skill to administer. There are 2 commercially available skinfold calipers, 1 digital and the other self-administered, that claim to accurately predict %BF. The primary purpose of this study was to validate these calipers using dual-energy x-ray absorptiometry (DXA) as a reference method in a sample of college-aged men and women. A secondary purpose of this study was to compare the validity of these calipers to the validity of arm-to-arm bioempedance analysis (BIA) (Omron, Shelton, Connecticut, U.S.A.), leg-to-leg BIA (Tanita, Arlington Heights, Illinois, U.S.A.), and 3-site skinfold equations (SUM3) using DXA as a reference method. Fifty college students (25 men and 25 women) from a kinesiology department who ranged in fitness levels volunteered to have %BF measured by the digital and self-administered skinfold calipers, Omron, Tanita, and SUM3. The digital and self-administered skinfold calipers had the poorest group predictive accuracy for the men and women (total error ranged from 7.9 to 10.9%BF) when compared to the other field methods. The digital skinfold caliper had good individual predictive accuracy in the men (95% limits of agreement [LOA] = ± 6.4%BF) and women (95% LOA = ± 4.9%BF) when compared to the other field methods. However, the self-administered skinfold caliper had poor individual predictive accuracy for the men (LOA = ± 8.6%BF) and the women (LOA = ± 7.5%BF) when compared to the other field methods. Compared to DXA, Tanita, Omron, and SUM3, we would not recommend using the digital or self-administered skinfold calipers for estimating %BF in college-aged men and women with similar body composition as the men and women in this study. We recommend using the SUM3 to estimate %BF.Keywords
This publication has 15 references indexed in Scilit:
- Evaluation of the BOD POD for Estimating Percent Body Fat in Collegiate Track and Field Female Athletes: A Comparison of Four MethodsJournal of Strength & Conditioning Research, 2008
- Estimating body fat in NCAA Division I female athletes: a five-compartment model validation of laboratory methodsEuropean Journal of Applied Physiology, 2008
- Validity and reliability of body composition analysers in children and adultsBritish Journal of Nutrition, 2008
- Cross-validation of generalised body composition equations with diverse young men and women: the Training Intervention and Genetics of Exercise Response (TIGER) StudyBritish Journal of Nutrition, 2008
- Comparison of Three Bioelectrical Impedance Methods with DXA in Overweight and Obese MenObesity, 2006
- Evaluation of Lunar Prodigy dual-energy X-ray absorptiometry for assessing body composition in healthy persons and patients by comparison with the criterion 4-component modelThe American Journal of Clinical Nutrition, 2006
- Comparison of Anthropometry to Dual Energy X-Ray Absorptiometry: A New Prediction Equation for WomenResearch Quarterly for Exercise and Sport, 2004
- Comparison of anthropometry to DXA: a new prediction equation for menEuropean Journal of Clinical Nutrition, 2004
- Techniques of Body Composition Assessment: A Review of Laboratory and Field MethodsResearch Quarterly for Exercise and Sport, 1999
- Bioimpedance analysis: evaluation of leg-to-leg system based on pressure contact foot-pad electrodesMedicine & Science in Sports & Exercise, 1997