Treatment of midshaft clavicular delayed and non-unions with anteroinferior locking compression plating
Open Access
- 2 April 2009
- journal article
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 130 (2) , 159-164
Abstract
Pain and impaired shoulder function are the predominant symptoms of midshaft clavicle non-unions. Obtaining consolidation and improvement of shoulder function is often successfully achieved with osteosynthesis and bone grafting. Most data in the literature pertain to plate osteosynthesis, placing the plate on the subcutaneous superior aspect of the clavicle. Although union rates are generally high, most patients require hardware removal as the plate is prominent under the skin causing pain and cosmetic problems. In the current retrospective study, we followed a cohort of 21 consecutive cases (20 patients) with a midshaft clavicular delayed or non-union, treated with anteroinferior plating using a 3.5 mm locking compression plate (LCP) for a mean of 30 months. We operated on 10 males and 10 females with a mean age of 48.2 years (range 16–65). There was one early plate failure that needed revision. Two patients required hardware removal because of prominence of the plate. All but two patients were satisfied with the final cosmetic result. The average DASH score at follow up was 22.8. Anteroinferior plating with a 3.5 mm LCP is a reliable and reproducible treatment of midshaft clavicular delayed and non-union regarding consolidation, function, cosmesis and reduction of second surgery.Keywords
This publication has 19 references indexed in Scilit:
- Failure of superior locking clavicle plate by axial pull-out of the lateral screws: A report of four casesJournal of Shoulder and Elbow Surgery, 2009
- Biomechanical Evaluation of Clavicle Fracture Plating Techniques: Does a Locking Plate Provide Improved Stability?Journal of Orthopaedic Trauma, 2008
- Locking Compression Plate in Long Standing Clavicular Nonunions With Poor Bone StockJournal of Trauma: Injury, Infection & Critical Care, 2008
- Functional outcome of surgical treatment of symptomatic nonunion and malunion of midshaft clavicle fracturesJournal of Shoulder and Elbow Surgery, 2007
- Anterior-inferior Plate Fixation of Middle-third Fractures and Nonunions of the ClavicleJournal of Orthopaedic Trauma, 2006
- A new approach for plate fixation of midshaft clavicular fracturesInjury, 2005
- Treatment of Acute Midshaft Clavicle Fractures: Systematic Review of 2144 FracturesJournal of Orthopaedic Trauma, 2005
- Closed treatment of displaced middle-third fractures of the clavicle gives poor resultsThe Journal of Bone and Joint Surgery. British volume, 1997
- Treatment of midshaft clavicular nonunion with plate fixation and autologous bone graftingJournal of Shoulder and Elbow Surgery, 1995
- Low-contact dynamic compression plating of the clavicleInjury, 1994