Sjoerd A. S. Stufkens
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Sjoerd A. S. Stufkens has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Michel Pieter Jozef Van Den Bekerom
Vrije Universiteit Amsterdam Faculteit der Gedrags- en Bewegingswetenschappen, Amsterdam, The Netherlands
2 shared publications - Peter Kloen
Department of Orthopedic Surgery and Sports Medicine, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands
2 shared publications - Beat Hintermann
Kantonsspital Liestal
1 shared publication - C. Niek van Dijk
University of Amsterdam
1 shared publication - Cornelis Niek van Dijk
University of Amsterdam
1 shared publication - Job N. Doornberg
Orthotrauma Research Center, University of Amsterdam Orthopaedic Residency Program (PGY 4), Amsterdam, The Netherlands
1 shared publication
Latest Publications
- 4 September 2013
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 95 (17) , e122-7
Long-Term Outcome of Pronation-External Rotation Ankle Fractures Treated with Syndesmotic Screws Only
Background: There is sparse information in the literature on the outcome of Maisonneuve-type pronation-external rotation ankle fractures treated with syndesmotic screws. The primary aim of this study was to determine the long-term results of such treatment of these fractures as indicated by standardized patient-based and physician-based outcome measures. The secondary aim was to identify predictors of the outcome with use of bivariate and multivariate statistical analysis. Methods: Fifty patients with pronation-external rotation (predominantly Maisonneuve) fractures were treated with open reduction and internal fixation of the syndesmosis utilizing only one or two screws. The results were evaluated at a mean of twenty-one years after the fracture utilizing three standardized outcomes instruments: (1) the Foot and Ankle Ability Measure (FAAM), (2) the American Orthopaedic Foot & Ankle Society (AOFAS) ankle-hindfoot scale, and (3) the Center for Epidemiologic Studies-Depression (CES-D) Scale. Osteoarthritis was graded according to the van Dijk and revised Takakura radiographic scoring systems. Bivariate and multivariate analyses were performed to identify predictors of long-term outcome. Results: Forty-four (92%) of forty-eighty patients had good or excellent AOFAS scores, and forty-four (90%) of forty-nine had good or excellent FAAM scores. Arthrodesis for severe osteoarthritis was performed in two patients. Radiographic evidence of osteoarthritis was observed in twenty-four (49%) of forty-nine patients. Multivariate analysis identified pain as the most important independent predictor of long-term ankle function as indicated by the AOFAS and FAAM scores, explaining 91% and 53% of the variation in scores, respectively. Analysis of pain as the dependent variable in bivariate analyses revealed that depression, ankle range of motion, and a subsequent surgery were significantly correlated with higher pain scores. No firm conclusions could be drawn after multivariate analysis of predictors of pain. Conclusions: Long-term functional outcomes at a mean of twenty-one years after pronation-external rotation ankle fractures treated with one or two syndesmotic screws were good to excellent in the great majority of patients despite substantial radiographic evidence of osteoarthritis in one-half of the patients. The most important predictor of long-term functional outcome was patient-reported pain rather than physician-reported function or posttraumatic osteoarthritis. There was no significant association between radiographic signs of posttraumatic osteoarthritis and perceived pain in the present series. Level of Evidence: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
- 4 September 2013
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 95 (17) , e122-7
Long-Term Outcome of Pronation-External Rotation Ankle Fractures Treated with Syndesmotic Screws Only
Background: There is sparse information in the literature on the outcome of Maisonneuve-type pronation-external rotation ankle fractures treated with syndesmotic screws. The primary aim of this study was to determine the long-term results of such treatment of these fractures as indicated by standardized patient-based and physician-based outcome measures. The secondary aim was to identify predictors of the outcome with use of bivariate and multivariate statistical analysis. Methods: Fifty patients with pronation-external rotation (predominantly Maisonneuve) fractures were treated with open reduction and internal fixation of the syndesmosis utilizing only one or two screws. The results were evaluated at a mean of twenty-one years after the fracture utilizing three standardized outcomes instruments: (1) the Foot and Ankle Ability Measure (FAAM), (2) the American Orthopaedic Foot & Ankle Society (AOFAS) ankle-hindfoot scale, and (3) the Center for Epidemiologic Studies-Depression (CES-D) Scale. Osteoarthritis was graded according to the van Dijk and revised Takakura radiographic scoring systems. Bivariate and multivariate analyses were performed to identify predictors of long-term outcome. Results: Forty-four (92%) of forty-eighty patients had good or excellent AOFAS scores, and forty-four (90%) of forty-nine had good or excellent FAAM scores. Arthrodesis for severe osteoarthritis was performed in two patients. Radiographic evidence of osteoarthritis was observed in twenty-four (49%) of forty-nine patients. Multivariate analysis identified pain as the most important independent predictor of long-term ankle function as indicated by the AOFAS and FAAM scores, explaining 91% and 53% of the variation in scores, respectively. Analysis of pain as the dependent variable in bivariate analyses revealed that depression, ankle range of motion, and a subsequent surgery were significantly correlated with higher pain scores. No firm conclusions could be drawn after multivariate analysis of predictors of pain. Conclusions: Long-term functional outcomes at a mean of twenty-one years after pronation-external rotation ankle fractures treated with one or two syndesmotic screws were good to excellent in the great majority of patients despite substantial radiographic evidence of osteoarthritis in one-half of the patients. The most important predictor of long-term functional outcome was patient-reported pain rather than physician-reported function or posttraumatic osteoarthritis. There was no significant association between radiographic signs of posttraumatic osteoarthritis and perceived pain in the present series. Level of Evidence: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
- Open Access
- 6 July 2012
- Published by Jaypee Brothers Medical Publishing in Strategies in Trauma and Limb Reconstruction
- Vol. 7 (2) , 73-85
The diagnosis and treatment of deltoid ligament lesions in supination–external rotation ankle fractures: a review
The supination–external rotation or Weber B type fracture exists as a stable and an unstable type. The unstable type has a medial malleolus fracture or deltoid ligament lesion in addition to a fibular fracture. The consensus is the unstable type and best treated by open reduction and internal fixation. The diagnostic process for a medial ligament lesion has been well investigated but there is no consensus as to the best method of assessment. The number of deltoid ruptures as a result of an external rotation mechanism is higher than previously believed. The derivation of the injury mechanism could provide information of the likely ligamentous lesion in several fracture patterns. The use of the Lauge-Hansen classification system in the assessment of the initial X-ray images can be helpful in predicting the involvement of the deltoid ligament but the reliability in terms of sensitivity and specificity is unknown. Clinical examination, stress radiography, magnetic resonance imaging, arthroscopy, and ultrasonography have been used to investigate medial collateral integrity in cases of ankle fractures. None of these has shown to possess the combination of being cost-effective, reliable and easy to use; currently gravity stress radiography is favoured and, in cases of doubt, arthroscopy could be of value. There is a disagreement as to the benefit of repair by suture of the deltoid ligament in cases of an acute rupture in combination with a lateral malleolar fracture. There is no evidence found for suturing but exploration is thought to be beneficial in case of interposition of medial structures.
- 6 July 2012
- Published by Jaypee Brothers Medical Publishing in Strategies in Trauma and Limb Reconstruction
- Vol. 7 (2) , 73-85
Open AccessThe diagnosis and treatment of deltoid ligament lesions in supination–external rotation ankle fractures: a review
The supination–external rotation or Weber B type fracture exists as a stable and an unstable type. The unstable type has a medial malleolus fracture or deltoid ligament lesion in addition to a fibular fracture. The consensus is the unstable type and best treated by open reduction and internal fixation. The diagnostic process for a medial ligament lesion has been well investigated but there is no consensus as to the best method of assessment. The number of deltoid ruptures as a result of an external rotation mechanism is higher than previously believed. The derivation of the injury mechanism could provide information of the likely ligamentous lesion in several fracture patterns. The use of the Lauge-Hansen classification system in the assessment of the initial X-ray images can be helpful in predicting the involvement of the deltoid ligament but the reliability in terms of sensitivity and specificity is unknown. Clinical examination, stress radiography, magnetic resonance imaging, arthroscopy, and ultrasonography have been used to investigate medial collateral integrity in cases of ankle fractures. None of these has shown to possess the combination of being cost-effective, reliable and easy to use; currently gravity stress radiography is favoured and, in cases of doubt, arthroscopy could be of value. There is a disagreement as to the benefit of repair by suture of the deltoid ligament in cases of an acute rupture in combination with a lateral malleolar fracture. There is no evidence found for suturing but exploration is thought to be beneficial in case of interposition of medial structures.
- Open Access
- 2 April 2009
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 130 (2) , 159-164
Treatment of midshaft clavicular delayed and non-unions with anteroinferior locking compression plating
Pain and impaired shoulder function are the predominant symptoms of midshaft clavicle non-unions. Obtaining consolidation and improvement of shoulder function is often successfully achieved with osteosynthesis and bone grafting. Most data in the literature pertain to plate osteosynthesis, placing the plate on the subcutaneous superior aspect of the clavicle. Although union rates are generally high, most patients require hardware removal as the plate is prominent under the skin causing pain and cosmetic problems. In the current retrospective study, we followed a cohort of 21 consecutive cases (20 patients) with a midshaft clavicular delayed or non-union, treated with anteroinferior plating using a 3.5 mm locking compression plate (LCP) for a mean of 30 months. We operated on 10 males and 10 females with a mean age of 48.2 years (range 16–65). There was one early plate failure that needed revision. Two patients required hardware removal because of prominence of the plate. All but two patients were satisfied with the final cosmetic result. The average DASH score at follow up was 22.8. Anteroinferior plating with a 3.5 mm LCP is a reliable and reproducible treatment of midshaft clavicular delayed and non-union regarding consolidation, function, cosmesis and reduction of second surgery.
- 2 April 2009
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 130 (2) , 159-164
Open AccessTreatment of midshaft clavicular delayed and non-unions with anteroinferior locking compression plating
Pain and impaired shoulder function are the predominant symptoms of midshaft clavicle non-unions. Obtaining consolidation and improvement of shoulder function is often successfully achieved with osteosynthesis and bone grafting. Most data in the literature pertain to plate osteosynthesis, placing the plate on the subcutaneous superior aspect of the clavicle. Although union rates are generally high, most patients require hardware removal as the plate is prominent under the skin causing pain and cosmetic problems. In the current retrospective study, we followed a cohort of 21 consecutive cases (20 patients) with a midshaft clavicular delayed or non-union, treated with anteroinferior plating using a 3.5 mm locking compression plate (LCP) for a mean of 30 months. We operated on 10 males and 10 females with a mean age of 48.2 years (range 16–65). There was one early plate failure that needed revision. Two patients required hardware removal because of prominence of the plate. All but two patients were satisfied with the final cosmetic result. The average DASH score at follow up was 22.8. Anteroinferior plating with a 3.5 mm LCP is a reliable and reproducible treatment of midshaft clavicular delayed and non-union regarding consolidation, function, cosmesis and reduction of second surgery.