A Novel Energy Absorption-Based Protection Scheme for Surge Transients in Large-Scale Wind Farm System
Authors:
Open Access
- 17 March 2022
- journal article
- research article
- Published by Frontiers Media SA in Frontiers in Energy Research
- Vol. 10
Abstract
Onshore wind farms are usually connected to the power grid by 35 kV transmission lines. Due to the high altitude of the wind turbines and their associated long transmission corridors, lightning activities are more frequent for onshore wind farms compared to the power plant in plain areas. In addition, the insulation levels of 10–35 kV distribution lines are generally low. All these facts make proper lightning strike protection a technical challenge for onshore wind farms. Taking a typical onshore wind farm as the testing object, the structure of the 35 kV distribution line connected to this wind farm is modeled by EMTP software in this paper. The leakage current and absorbed energy of the arrester at the head tower when lightning currents of different amplitudes inject into the overhead line are studied. By calculating the energy accumulated in the arrester within 100 µs, the causes of the lightning trip and damage to the arrester of the distribution line, i.e., the energy accumulation mechanism, are clarified. Eventually, the lightning protection updating scheme for this distribution line is proposed: a combination of refitting the porcelain cross arm at the head and end of the tower and filling the grounding body of the tower with a drag-reduction agent, which shows that the lightning resistance level of the distribution can be improved by 50 times in maximum.Keywords
This publication has 16 references indexed in Scilit:
- Estimation of Energy Stress of Surge Arresters Considering the High-Frequency Behavior of Grounding SystemsIEEE Transactions on Electromagnetic Compatibility, 2017
- Thermal balance diagram modelling of surge arrester for thermal stability analysis considering ZnO varistor degradation effectIET Generation, Transmission & Distribution, 2016
- Energy absorption capacity of a 500 kV surge arrester for direct and multiple lightning strokesIEEE Transactions on Dielectrics and Electrical Insulation, 2015
- Probabilistic Risk Assessment of MV Insulator Flashover Under Combined AC and Lightning-Induced OvervoltagesIEEE Transactions on Power Delivery, 2015
- Probabilistic evaluation of failure risk of transmission line surge arresters caused by lightning flashIET Generation, Transmission & Distribution, 2014
- Optimisation of arrester location in risk assessment in distribution networkIET Generation, Transmission & Distribution, 2014
- Analytical Formulations for Lightning-Induced Voltage CalculationsIEEE Transactions on Electromagnetic Compatibility, 2012
- Artificial Neural Networks Used for ZnO Arresters DiagnosisIEEE Transactions on Power Delivery, 2009
- Influence of thermal insulation position in building envelope on the space cooling of high-rise residential buildings in Hong KongEnergy and Buildings, 2001
- Distribution arrester failures caused by lightning current flowing from customer's structure into distribution linesIEEE Transactions on Power Delivery, 1999