Reconfiguring a Plane-Parallel Transmission Ionization Chamber to Extend the Operating Range into the Ultra-High Dose-per-pulse Regime
- 1 March 2024
- journal article
- research article
- Published by Radiation Research Society in Radiation Research
- Vol. 201 (3) , 252-260
Abstract
This study aims to investigate the feasibility of enhancing the charge collection efficiency (CCE) of a transmission chamber by reconfiguring its design and operation. The goal was to extend the range of dose-per-pulse (DPP) values with no or minimal recombination effects up to the ultra-high dose rate (UHDR) regime. The response of two transmission chambers, with electrode distance of 1 mm and 0.6 mm, respectively, was investigated as a function of applied voltage. The chambers were mounted one-by-one in the electron applicator of a 10 MeV FLASH-modified clinical linear accelerator. The chamber signals were measured as a function of nominal DPP, which was determined at the depth of dose maximum using EBT-XD film in solid water and ranged from 0.6 mGy per pulse to 0.9 Gy per pulse, for both the standard voltage of 320 V and the highest possible safe voltage of 1,200 V. The CCE was calculated and fitted with an empirical logistic function that incorporated the electrode distance and the chamber voltage. The CCE decreased with increased DPP. The CCE at the highest achievable DPP was 24% (36%) at 320 V and 51% (82%) at 1,200 V, for chambers with 1 mm (0.6 mm) electrode distance. For the combination of 1,200 V- and 0.6-mm electrode distance, the CCE was ∼100% for average dose rate up to 70 Gy/s at the depth of dose maximum in the phantom at a source-to-surface distance of 100 cm. Our findings indicate that minor modifications to a plane-parallel transmission chamber can substantially enhance the CCE and extending the chamber's operating range to the UHDR regime. This supports the potential of using transmission chamber-based monitoring solutions for UHDR beams, which could facilitate the delivery of UHDR treatments using an approach similar to conventional clinical delivery.Keywords
This publication has 34 references indexed in Scilit:
- Dual beam‐current transformer design for monitoring and reporting of electron ultra‐high dose rate (FLASH) beam parametersJournal of Applied Clinical Medical Physics, 2023
- Proton FLASH Radiotherapy for the Treatment of Symptomatic Bone MetastasesJAMA Oncology, 2023
- Technical note: Validation of an ultrahigh dose rate pulsed electron beam monitoring system using a current transformer for FLASH preclinical studiesMedical Physics, 2022
- Implementation and validation of a beam‐current transformer on a medical pulsed electron beam LINAC for FLASH‐RT beam monitoringJournal of Applied Clinical Medical Physics, 2021
- Radiation shielding and safety implications following linac conversion to an electron FLASH‐RT unitMedical Physics, 2021
- Dosimetry with a clinical linac adapted to FLASH electron beamsJournal of Applied Clinical Medical Physics, 2021
- Commissioning of an ultra‐high dose rate pulsed electron beam medical LINAC for FLASH RT preclinical animal experiments and future clinical human protocolsMedical Physics, 2021
- Ion collection efficiency of ionization chambers in ultra‐high dose‐per‐pulse electron beamsMedical Physics, 2020
- High dose‐per‐pulse electron beam dosimetry: Commissioning of the Oriatron eRT6 prototype linear accelerator for preclinical useMedical Physics, 2017
- High dose‐per‐pulse electron beam dosimetry — A model to correct for the ion recombination in the Advanced Markus ionization chamberMedical Physics, 2017