Graphite Supported Preparation (GSP) of α-Cyano-4-Hydroxycinnamic Acid (CHCA) for Matrix-Assisted Laser Desorption/Ionization Mass Spectrometry (MALDI-MS) for Peptides and Proteins
Authors:
- 20 September 2012
- journal article
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 23 (11) , 1949-1954
Abstract
Graphite as MALDI matrix or in combination with other substances has been reported in recent years. Here, we demonstrate that graphite can be used as target coating supporting the crystallization of the α-cyano-4-hydroxycinnamic acid matrix. A conventional dried-droplet preparation of matrix and analyte solution on a graphite-coated metal target leads to a thin, uniform layer of cubic crystals with about 1 μm edge length. Commercially available graphite powder of 1–2 μm particle size is gently wiped over the target using a cotton Q-tip, leading to an ultra-thin, not-visible film. This surface modification considerably improves analysis of peptides and proteins for MALDI MS using conventional dried-droplet preparation. Compared with untreated targets, the signal intensities of standard peptides are up to eight times higher when using the graphite supported crystallization. The relative standard deviation in peak area of angiotensin II for sample amounts between 1 and 50 fmol is reduced to about 15 % compared with 45 % for untreated sample holders. For a quantification of 1 fmol of the peptide using an internal standard the coefficient of variation is reduced to 3.5 % from 8 %. The new graphite supported preparation (GSP) protocol is very simple and does not require any technical nor manual skills. All standard solvents for peptides and proteins can be used.Keywords
This publication has 19 references indexed in Scilit:
- 4-Chloro-α-cyanocinnamic acid is an advanced, rationally designed MALDI matrixProceedings of the National Academy of Sciences, 2008
- A fast screening MALDI method for the detection of cocaine and its metabolites in hairJournal of Mass Spectrometry, 2008
- MALDI Sample Preparation: the Ultra Thin Layer MethodJournal of Visualized Experiments, 2007
- Observation of Low Molecular Weight Poly(methylsilsesquioxane)s by Graphite Plate Laser Desorption/Ionization Time-of-Flight Mass SpectrometryAnalytical Chemistry, 2000
- Two-Layer Sample Preparation: A Method for MALDI-MS Analysis of Complex Peptide and Protein MixturesAnalytical Chemistry, 1999
- Delayed extraction time-of-flight MALDI mass spectrometry of proteins above 25000 DaJournal of Mass Spectrometry, 1997
- Improved Resolution and Very High Sensitivity in MALDI TOF of Matrix Surfaces Made by Fast EvaporationAnalytical Chemistry, 1994
- Reproducibility and quantitation of matrix-assisted laser desorption ionization mass spectrometry: Effects of nitrocellulose on peptide ion yieldsJournal of Mass Spectrometry, 1993
- Cinnamic acid derivatives as matrices for ultraviolet laser desorption mass spectrometry of proteinsRapid Communications in Mass Spectrometry, 1989
- Laser desorption ionization of proteins with molecular masses exceeding 10,000 daltonsAnalytical Chemistry, 1988