Simple Smart Implants: Simultaneous Monitoring of Loosening and Temperature in Orthopaedics With an Embedded Ultrasound Transducer
- 20 January 2021
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 15 (1) , 102-110
Abstract
Implant failure can have devastating consequences on patient outcomes following joint replacement. Time to diagnosis affects subsequent treatment success, but current diagnostics do not give early warning and lack accuracy. This research proposes an embedded ultrasound system to monitor implant fixation and temperature - a potential indicator of infection. Requiring only two implanted components: a piezoelectric transducer and a coil, pulse-echo responses are elicited via a three-coil inductive link. This passive system avoids the need for batteries, energy harvesters, and microprocessors, resulting in minimal changes to existing implant architecture. Proof-of-concept was demonstrated in vitro for a titanium plate cemented into synthetic bone, using a small embedded coil with 10 mm diameter. Gross loosening - simulated by completely debonding the implant-cement interface - was detectable with 95% confidence at up to 12 mm implantation depth. Temperature was calibrated with root mean square error of 0.19°C at 5 mm, with measurements accurate to ±1°C with 95% confidence up to 6 mm implantation depth. These data demonstrate that with only a transducer and coil implanted, it is possible to measure fixation and temperature simultaneously. This simple smart implant approach minimises the need to modify well-established implant designs, and hence could enable mass-market adoption.Keywords
Funding Information
- Engineering and Physical Sciences Research Council
- Doctoral Training Account Award (EP/S022546/1 (RvA))
This publication has 42 references indexed in Scilit:
- Value of digital telethermography for the diagnosis of septic knee prosthesis: a prospective cohort studyBMC Musculoskeletal Disorders, 2013
- High-Tech Hip Implant for Wireless Temperature Measurements In VivoPLOS ONE, 2012
- Telethermographic findings after uncomplicated and septic total knee replacementThe Knee, 2012
- Tibial Forces Measured In Vivo After Total Knee ArthroplastyThe Journal of Arthroplasty, 2006
- Aseptic loosening, not only a question of wear: A review of different theoriesActa Orthopaedica, 2006
- Frictional heating of total hip implants, Part 1: measurements in patientsJournal of Biomechanics, 2001
- Development of a computer model for an ultrasonic polymer film transducer systemNDT & E International, 1998
- The dielectric properties of biological tissues: I. Literature surveyPhysics in Medicine & Biology, 1996
- Instrumented implant for measuring tibiofemoral forcesJournal of Biomechanics, 1996
- Multichannel strain gauge telemetry for orthopaedic implantsJournal of Biomechanics, 1988