Cardiac CT: Imaging of and Through Cardiac Devices
Authors:
- 10 July 2012
- journal article
- research article
- Published by Springer Nature in Current Cardiovascular Imaging Reports
- Vol. 5 (5) , 328-336
Abstract
For patients with cardiac devices, cardiac computed tomography (CT) remains the mainstay for imaging due to its superior resolution as compared with echocardiography and nuclear studies and no contraindication to metal as with cardiac magnetic resonance imaging. This review focuses on the evaluation and pitfalls of coronary arterial imaging in patients with devices, such as pacemakers, implantable defibrillators, cardiac resynchronization therapy (CRT), as well as complications such as lead perforation and safety concerns of CT interference. We discuss both pre- and post-procedural CRT assessment for coronary venous imaging and pre-procedural myocardial scar assessment to localize regions of scar and peri-infarct zone to facilitate ventricular tachycardia ablation in patients with devices. We describe potential new research on dyssynchrony and integration with myocardial scar and site of latest activation for patients with or being considered for CRT. We detail the utility of CT for the assessment of proper function and complications in patients with left ventricular assist device implantation.Keywords
This publication has 49 references indexed in Scilit:
- The Role of Echocardiography and Other Imaging Modalities in Patients With Left Ventricular Assist DevicesJACC: Cardiovascular Imaging, 2010
- Current status of cardiac transplantation and mechanical circulatory supportCurrent Heart Failure Reports, 2009
- Imaging of the coronary venous system in patients with congestive heart failure: comparison of 16 slice MSCT and retrograde coronary sinus venographyThe International Journal of Cardiovascular Imaging, 2008
- Role of Multislice Computed Tomography for Preprocedural Evaluation Before Revision of a Chronically Implanted Transvenous Left Ventricular LeadThe American Journal of Cardiology, 2007
- Effects of CT Irradiation on Implantable Cardiac Rhythm Management Devices1Radiology, 2007
- Does High-Power Computed Tomography Scanning Equipment Affect the Operation of Pacemakers?Circulation Journal, 2006
- Registration of Three-Dimensional Left Atrial Computed Tomographic Images With Projection Images Obtained Using FluoroscopyCirculation, 2005
- Imaging of the Cardiac Venous System: Comparison of MDCT and Conventional AngiographyAmerican Journal of Roentgenology, 2005
- Noninvasive Evaluation of Cardiac Veins with 16-MDCT AngiographyAmerican Journal of Roentgenology, 2005
- Influence of high-energy photon beam irradiation on pacemaker operationPhysics in Medicine & Biology, 2002