Quynh A. Truong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Quynh A. Truong has a total of 94 co-authors. Here are the top co-authors by number of shared publications:
Udo Hoffmann
Cardiac MR PET CT Program, Division of Cardiology and Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA
16 shared publicationsFabian Bamberg
Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts
8 shared publicationsJohn T. Nagurney
Emergency Department, Massachusetts General Hospital, Harvard Medical School, Boston, MA
7 shared publicationsAmir A. Mahabadi
5 shared publications- Christopher L. Schlett
Department of Diagnostic and Interventional Radiology, Medical Center – University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
5 shared publications - Matthias Frank Kriegel
Department of Ophthalmology, St. Franziskus Hospital, Muenster, Germany
4 shared publications
Latest Publications
- 23 May 2014
- Published by Springer Nature in Current Cardiovascular Imaging Reports
- Vol. 7 (7) , 1-7
Novel Biomarkers: Utility in Patients with Acute Chest Pain and Relationship to Coronary Artery Disease on Coronary CT Angiography
Acute chest pain remains one of the most common patient presentations encountered in the emergency department. With the evolution of biomarkers and improvement in cardiac imaging there has been advancement in risk stratification of patients, but millions of dollars continue to be spent in the assessment of chest pain. Investigators have explored possible comparative alternatives to the traditional work up of chest pain. In this review, we will discuss the current state of biomarker use in the evaluation of acute chest pain. We will review established and emerging circulating biomarkers and their addition to cardiac CT for appropriate diagnosis of coronary artery disease.
- 23 May 2014
- Published by Springer Nature in Current Cardiovascular Imaging Reports
- Vol. 7 (7) , 1-7
Novel Biomarkers: Utility in Patients with Acute Chest Pain and Relationship to Coronary Artery Disease on Coronary CT Angiography
Acute chest pain remains one of the most common patient presentations encountered in the emergency department. With the evolution of biomarkers and improvement in cardiac imaging there has been advancement in risk stratification of patients, but millions of dollars continue to be spent in the assessment of chest pain. Investigators have explored possible comparative alternatives to the traditional work up of chest pain. In this review, we will discuss the current state of biomarker use in the evaluation of acute chest pain. We will review established and emerging circulating biomarkers and their addition to cardiac CT for appropriate diagnosis of coronary artery disease.
- 1 September 2013
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Imaging
- Vol. 6 (5) , 784-789
Assessment of Mitral Valve Adaptation With Gated Cardiac Computed Tomography
Background—: Mitral valve (MV) enlargement is a compensatory mechanism capable of preventing functional mitral regurgitation (FMR) in dilated ventricles. Total leaflet area and its relation with closure area measured by 3-dimensional (3D) echocardiography have been related to FMR. Whether these parameters can be assessed with other imaging modalities is not known. Our objectives are to compare cardiac computed tomography (CT)–based measurements of MV leaflets with 3D echocardiography and determine the relationship of these metrics to the presence of FMR. Methods and Results—: We used 2 cohorts of patients who had cardiac CT to measure MV total leaflet, closure, and annulus areas. In cohort 1 (26 patients), we validated these CT metrics to 3D echocardiography. In cohort 2 (66 patients), we assessed the relation of MV size with the presence of FMR in 3 populations: heart failure with FMR, heart failure without FMR, and normal controls. Cardiac CT and 3D echocardiography produced similar results for total leaflet ( R 2 =0.97), closure ( R 2 =0.89), and annulus areas ( R 2 =0.84). MV size was the largest in heart failure without FMR compared with controls and patients with FMR (9.1±1.7 versus 7.5±1.0 versus 8.1±0.9 cm 2 /m 2 ; P P <0.01). Conclusions—: MV size measured by CT is comparable with 3D echocardiography. MV enlargement in cardiomyopathy suggests leaflet adaptation. Patients with FMR have inadequate adaptation as reflected by decreased ratios of leaflet area and areas determined by ventricle size (annulus and closure areas). These measurements provide additional insight into the mechanism of FMR.
- 1 September 2013
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Imaging
- Vol. 6 (5) , 784-789
Assessment of Mitral Valve Adaptation With Gated Cardiac Computed Tomography
Background—: Mitral valve (MV) enlargement is a compensatory mechanism capable of preventing functional mitral regurgitation (FMR) in dilated ventricles. Total leaflet area and its relation with closure area measured by 3-dimensional (3D) echocardiography have been related to FMR. Whether these parameters can be assessed with other imaging modalities is not known. Our objectives are to compare cardiac computed tomography (CT)–based measurements of MV leaflets with 3D echocardiography and determine the relationship of these metrics to the presence of FMR. Methods and Results—: We used 2 cohorts of patients who had cardiac CT to measure MV total leaflet, closure, and annulus areas. In cohort 1 (26 patients), we validated these CT metrics to 3D echocardiography. In cohort 2 (66 patients), we assessed the relation of MV size with the presence of FMR in 3 populations: heart failure with FMR, heart failure without FMR, and normal controls. Cardiac CT and 3D echocardiography produced similar results for total leaflet ( R 2 =0.97), closure ( R 2 =0.89), and annulus areas ( R 2 =0.84). MV size was the largest in heart failure without FMR compared with controls and patients with FMR (9.1±1.7 versus 7.5±1.0 versus 8.1±0.9 cm 2 /m 2 ; P P <0.01). Conclusions—: MV size measured by CT is comparable with 3D echocardiography. MV enlargement in cardiomyopathy suggests leaflet adaptation. Patients with FMR have inadequate adaptation as reflected by decreased ratios of leaflet area and areas determined by ventricle size (annulus and closure areas). These measurements provide additional insight into the mechanism of FMR.
- 25 June 2013
- Published by Wolters Kluwer Health in Circulation
- Vol. 127 (25) , 2494-2502
Sex Differences in the Effectiveness of Early Coronary Computed Tomographic Angiography Compared With Standard Emergency Department Evaluation for Acute Chest Pain
Background—: We evaluate sex-based differences in the effectiveness of early cardiac computed tomographic angiography (CCTA) and standard emergency department (ED) evaluation in patients with acute chest pain. Methods and Results—: In the Rule-Out Myocardial Infarction With Computer-Assisted Tomography (ROMICAT)-II multicenter, controlled trial, we randomized 1000 patients (47% women) 40 to 74 years of age with symptoms suggestive of acute coronary syndrome to an early CCTA or standard ED evaluation. In this prespecified analysis, women in the CCTA arm had a greater reduction in length of stay, lower hospital admission rates, and lesser increased cumulative radiation dose than men in a comparison of ED strategies ( P for interaction ≤0.02). Although women had lower acute coronary syndrome rates than men (3% versus 12%; P P for interaction P =0.11). There was no missed acute coronary syndrome for either sex. No difference was observed in major adverse cardiac events between sexes and ED strategies ( P for interaction =0.39). Women had more normal CCTA examinations than men (58% versus 37%; P P =0.0001), but similar normalcy rates for functional testing ( P =0.65). Men in the CCTA arm had the highest rate of invasive coronary angiography (18%), whereas women had comparable low 5% rates regardless of ED strategy. Conclusions—: This trial provides data supporting an early CCTA strategy as an attractive option in women presenting to the ED with symptoms suggestive of acute coronary syndrome. The findings may be explained by lower CAD prevalence and severity in women than men. Clinical Trial Registration—: URL: http://www.clinicaltrials.gov . Unique identifier: NCT01084239.
- 25 June 2013
- Published by Wolters Kluwer Health in Circulation
- Vol. 127 (25) , 2494-2502
Sex Differences in the Effectiveness of Early Coronary Computed Tomographic Angiography Compared With Standard Emergency Department Evaluation for Acute Chest Pain
Background—: We evaluate sex-based differences in the effectiveness of early cardiac computed tomographic angiography (CCTA) and standard emergency department (ED) evaluation in patients with acute chest pain. Methods and Results—: In the Rule-Out Myocardial Infarction With Computer-Assisted Tomography (ROMICAT)-II multicenter, controlled trial, we randomized 1000 patients (47% women) 40 to 74 years of age with symptoms suggestive of acute coronary syndrome to an early CCTA or standard ED evaluation. In this prespecified analysis, women in the CCTA arm had a greater reduction in length of stay, lower hospital admission rates, and lesser increased cumulative radiation dose than men in a comparison of ED strategies ( P for interaction ≤0.02). Although women had lower acute coronary syndrome rates than men (3% versus 12%; P P for interaction P =0.11). There was no missed acute coronary syndrome for either sex. No difference was observed in major adverse cardiac events between sexes and ED strategies ( P for interaction =0.39). Women had more normal CCTA examinations than men (58% versus 37%; P P =0.0001), but similar normalcy rates for functional testing ( P =0.65). Men in the CCTA arm had the highest rate of invasive coronary angiography (18%), whereas women had comparable low 5% rates regardless of ED strategy. Conclusions—: This trial provides data supporting an early CCTA strategy as an attractive option in women presenting to the ED with symptoms suggestive of acute coronary syndrome. The findings may be explained by lower CAD prevalence and severity in women than men. Clinical Trial Registration—: URL: http://www.clinicaltrials.gov . Unique identifier: NCT01084239.
- 25 July 2012
- Published by Springer Nature in Current Cardiology Reports
- Vol. 14 (5) , 584-592
Preprocedural Imaging for Patients with Atrial Fibrillation and Heart Failure
Various electrophysiological procedures and device implantation has been shown to improve morbidity and mortality in patients with atrial fibrillation (AF) and patients with heart failure (HF). Noninvasive cardiac imaging is used extensively in the preprocedural patient selection and for procedural guidance. In this review, we will discuss the application of preprocedural cardiac imaging in patients with AF prior to pulmonary vein and left atrial ablation as well as insertion of left atrial occluder device. We also discuss the role of noninvasive cardiac imaging in the selection of appropriate HF patients for device therapy as well as their use in guiding implantation of biventricular pacemaker for cardiac resynchronization therapy by assessing left ventricular ejection fraction, coronary venous anatomy, mechanical dyssynchrony and myocardial scar. We describe new research associated with preprocedural imaging in these patient cohorts.
- 25 July 2012
- Published by Springer Nature in Current Cardiology Reports
- Vol. 14 (5) , 584-592
Preprocedural Imaging for Patients with Atrial Fibrillation and Heart Failure
Various electrophysiological procedures and device implantation has been shown to improve morbidity and mortality in patients with atrial fibrillation (AF) and patients with heart failure (HF). Noninvasive cardiac imaging is used extensively in the preprocedural patient selection and for procedural guidance. In this review, we will discuss the application of preprocedural cardiac imaging in patients with AF prior to pulmonary vein and left atrial ablation as well as insertion of left atrial occluder device. We also discuss the role of noninvasive cardiac imaging in the selection of appropriate HF patients for device therapy as well as their use in guiding implantation of biventricular pacemaker for cardiac resynchronization therapy by assessing left ventricular ejection fraction, coronary venous anatomy, mechanical dyssynchrony and myocardial scar. We describe new research associated with preprocedural imaging in these patient cohorts.
- 10 July 2012
- Published by Springer Nature in Current Cardiovascular Imaging Reports
- Vol. 5 (5) , 328-336
Cardiac CT: Imaging of and Through Cardiac Devices
For patients with cardiac devices, cardiac computed tomography (CT) remains the mainstay for imaging due to its superior resolution as compared with echocardiography and nuclear studies and no contraindication to metal as with cardiac magnetic resonance imaging. This review focuses on the evaluation and pitfalls of coronary arterial imaging in patients with devices, such as pacemakers, implantable defibrillators, cardiac resynchronization therapy (CRT), as well as complications such as lead perforation and safety concerns of CT interference. We discuss both pre- and post-procedural CRT assessment for coronary venous imaging and pre-procedural myocardial scar assessment to localize regions of scar and peri-infarct zone to facilitate ventricular tachycardia ablation in patients with devices. We describe potential new research on dyssynchrony and integration with myocardial scar and site of latest activation for patients with or being considered for CRT. We detail the utility of CT for the assessment of proper function and complications in patients with left ventricular assist device implantation.
- 10 July 2012
- Published by Springer Nature in Current Cardiovascular Imaging Reports
- Vol. 5 (5) , 328-336
Cardiac CT: Imaging of and Through Cardiac Devices
For patients with cardiac devices, cardiac computed tomography (CT) remains the mainstay for imaging due to its superior resolution as compared with echocardiography and nuclear studies and no contraindication to metal as with cardiac magnetic resonance imaging. This review focuses on the evaluation and pitfalls of coronary arterial imaging in patients with devices, such as pacemakers, implantable defibrillators, cardiac resynchronization therapy (CRT), as well as complications such as lead perforation and safety concerns of CT interference. We discuss both pre- and post-procedural CRT assessment for coronary venous imaging and pre-procedural myocardial scar assessment to localize regions of scar and peri-infarct zone to facilitate ventricular tachycardia ablation in patients with devices. We describe potential new research on dyssynchrony and integration with myocardial scar and site of latest activation for patients with or being considered for CRT. We detail the utility of CT for the assessment of proper function and complications in patients with left ventricular assist device implantation.
- 1 June 2012
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 5 (3) , 521-530
Pulmonary Venous Anatomy Imaging With Low-Dose, Prospectively ECG-Triggered, High-Pitch 128-Slice Dual-Source Computed Tomography
Background—The efforts to reduce radiation from cardiac computed tomography (CT) are essential. Using a prospectively triggered, high-pitch dual-source CT protocol, we aim to determine the radiation dose and image quality in patients undergoing pulmonary vein (PV) imaging. Methods and Results—In 94 patients (61±9 years; 71% male) who underwent 128-slice dual-source CT (pitch 3.4), radiation dose and image quality were assessed and compared between 69 patients with sinus rhythm and 25 patients with atrial fibrillation. Radiation dose was compared in a subset of 19 patients with prior retrospective or prospectively triggered CT PV scans without high pitch. In a subset of 18 patients with prior magnetic resonance imaging for PV assessment, PV anatomy and scan duration were compared with high-pitch CT. Using the high-pitch protocol, total effective radiation dose was 1.4 (1.3, 1.9) mSv, with no difference between sinus rhythm and atrial fibrillation (1.4 versus 1.5 mSv; P=0.22). No high-pitch CT scans were no...
- 1 June 2012
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 5 (3) , 521-530
Pulmonary Venous Anatomy Imaging With Low-Dose, Prospectively ECG-Triggered, High-Pitch 128-Slice Dual-Source Computed Tomography
Background—The efforts to reduce radiation from cardiac computed tomography (CT) are essential. Using a prospectively triggered, high-pitch dual-source CT protocol, we aim to determine the radiation dose and image quality in patients undergoing pulmonary vein (PV) imaging. Methods and Results—In 94 patients (61±9 years; 71% male) who underwent 128-slice dual-source CT (pitch 3.4), radiation dose and image quality were assessed and compared between 69 patients with sinus rhythm and 25 patients with atrial fibrillation. Radiation dose was compared in a subset of 19 patients with prior retrospective or prospectively triggered CT PV scans without high pitch. In a subset of 18 patients with prior magnetic resonance imaging for PV assessment, PV anatomy and scan duration were compared with high-pitch CT. Using the high-pitch protocol, total effective radiation dose was 1.4 (1.3, 1.9) mSv, with no difference between sinus rhythm and atrial fibrillation (1.4 versus 1.5 mSv; P=0.22). No high-pitch CT scans were no...
- 1 June 2012
- Published by Elsevier in American Heart Journal
- Vol. 163 (6) , 972-979.e1
Multi-marker strategy of natriuretic peptide with either conventional or high-sensitivity troponin-T for acute coronary syndrome diagnosis in emergency department patients with chest pain: From the “Rule Out Myocardial Infarction Using Computer Assisted Tomography” (ROMICAT) trial
- 1 June 2012
- Published by Elsevier in American Heart Journal
- Vol. 163 (6) , 972-979.e1
Multi-marker strategy of natriuretic peptide with either conventional or high-sensitivity troponin-T for acute coronary syndrome diagnosis in emergency department patients with chest pain: From the “Rule Out Myocardial Infarction Using Computer Assisted Tomography” (ROMICAT) trial
- 14 May 2012
- Published by Elsevier in International Journal of Cardiology
- Vol. 167 (4) , 1616-1621
Aortic distensibility and its relationship to coronary and thoracic atherosclerosis plaque and morphology by MDCT: Insights from the ROMICAT Trial
- 14 May 2012
- Published by Elsevier in International Journal of Cardiology
- Vol. 167 (4) , 1616-1621
Aortic distensibility and its relationship to coronary and thoracic atherosclerosis plaque and morphology by MDCT: Insights from the ROMICAT Trial
- 1 January 2012
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Imaging
- Vol. 5 (1) , 147-154
Reference Values for Normal Pulmonary Artery Dimensions by Noncontrast Cardiac Computed Tomography
Background—: Main pulmonary artery diameter (mPA) and ratio of mPA to ascending aorta diameter (ratio PA) derived from chest CT are commonly reported in clinical practice. We determined the age- and sex-specific distribution and normal reference values for mPA and ratio PA by CT in an asymptomatic community-based population. Methods and Results—: In 3171 men and women (mean age, 51±10 years; 51% men) from the Framingham Heart Study, a noncontrast, ECG-gated, 8-slice cardiac multidetector CT was performed. We measured the mPA and transverse axial diameter of the ascending aorta at the level of the bifurcation of the right pulmonary artery and calculated the ratio PA. We defined the healthy referent cohort (n=706) as those without obesity, hypertension, current and past smokers, chronic obstructive pulmonary disease, history of pulmonary embolism, diabetics, cardiovascular disease, and heart valve surgery. The mean mPA diameter in the overall cohort was 25.1±2.8 mm and mean ratio PA was 0.77±0.09. The sex-specific 90th percentile cutoff value for mPA diameter was 28.9 mm in men and 26.9 mm in women and was associated with increase risk for self-reported dyspnea (adjusted odds ratio, 1.31; P =0.02). The 90th percentile cutoff value for ratio PA of the healthy referent group was 0.91, similar between sexes but decreased with increasing age (range, 0.82–0.94), though not associated with dyspnea. Conclusions—: For simplicity, we established 29 mm in men and 27 mm in women as sex-specific normative reference values for mPA and 0.9 for ratio PA.
- 1 January 2012
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Imaging
- Vol. 5 (1) , 147-154
Reference Values for Normal Pulmonary Artery Dimensions by Noncontrast Cardiac Computed Tomography
Background—: Main pulmonary artery diameter (mPA) and ratio of mPA to ascending aorta diameter (ratio PA) derived from chest CT are commonly reported in clinical practice. We determined the age- and sex-specific distribution and normal reference values for mPA and ratio PA by CT in an asymptomatic community-based population. Methods and Results—: In 3171 men and women (mean age, 51±10 years; 51% men) from the Framingham Heart Study, a noncontrast, ECG-gated, 8-slice cardiac multidetector CT was performed. We measured the mPA and transverse axial diameter of the ascending aorta at the level of the bifurcation of the right pulmonary artery and calculated the ratio PA. We defined the healthy referent cohort (n=706) as those without obesity, hypertension, current and past smokers, chronic obstructive pulmonary disease, history of pulmonary embolism, diabetics, cardiovascular disease, and heart valve surgery. The mean mPA diameter in the overall cohort was 25.1±2.8 mm and mean ratio PA was 0.77±0.09. The sex-specific 90th percentile cutoff value for mPA diameter was 28.9 mm in men and 26.9 mm in women and was associated with increase risk for self-reported dyspnea (adjusted odds ratio, 1.31; P =0.02). The 90th percentile cutoff value for ratio PA of the healthy referent group was 0.91, similar between sexes but decreased with increasing age (range, 0.82–0.94), though not associated with dyspnea. Conclusions—: For simplicity, we established 29 mm in men and 27 mm in women as sex-specific normative reference values for mPA and 0.9 for ratio PA.