Automated tube voltage adaptation in head and neck computed tomography between 120 and 100 kV: effects on image quality and radiation dose
Authors:
- 25 June 2014
- journal article
- Published by Springer Nature in Neuroradiology
- Vol. 56 (9) , 797-803
Abstract
Low tube voltage allows for computed tomography (CT) imaging with increased iodine contrast at reduced radiation dose. We sought to evaluate the image quality and potential dose reduction using a combination of attenuation based tube current modulation (TCM) and automated tube voltage adaptation (TVA) between 100 and 120 kV in CT of the head and neck. One hundred thirty consecutive patients with indication for head and neck CT were examined with a 128-slice system capable of TCM and TVA. Reference protocol was set at 120 kV. Tube voltage was reduced to 100 kV whenever proposed by automated analysis of the localizer. An additional small scan aligned to the jaw was performed at a fixed 120 kV setting. Image quality was assessed by two radiologists on a standardized Likert-scale and measurements of signal- (SNR) and contrast-to-noise ratio (CNR). Radiation dose was assessed as CTDIvol. Diagnostic image quality was excellent in both groups and did not differ significantly (p = 0.34). Image noise in the 100 kV data was increased and SNR decreased (17.8/9.6) in the jugular veins and the sternocleidomastoid muscle when compared to 120 kV (SNR 24.4/10.3), but not in fatty tissue and air. However, CNR did not differ statistically significant between 100 (23.5/14.4/9.4) and 120 kV data (24.2/15.3/8.6) while radiation dose was decreased by 7–8 %. TVA between 100 and 120 kV in combination with TCM led to a radiation dose reduction compared to TCM alone, while keeping CNR constant though maintaining diagnostic image quality.Keywords
This publication has 21 references indexed in Scilit:
- CT Angiography of the Head-and-Neck Vessels Acquired with Low Tube Voltage, Low Iodine, and Iterative Image Reconstruction: Clinical Evaluation of Radiation Dose and Image QualityPLOS ONE, 2013
- Attenuation-based automatic kilovolt (kV)-selection in computed tomography of the chest: Effects on radiation exposure and image qualityEuropean Journal of Radiology, 2013
- Carotid CTA: Radiation Exposure and Image Quality with the Use of Attenuation-Based, Automated Kilovolt SelectionAmerican Journal of Neuroradiology, 2013
- High-pitch dual-source CT angiography of supra-aortic arteries: assessment of image quality and radiation doseNeuroradiology, 2012
- Low Kilovoltage CT of the Neck with 70 kVp: Comparison with a Standard ProtocolAmerican Journal of Neuroradiology, 2012
- Automatic selection of tube potential for radiation dose reduction in CT: A general strategyMedical Physics, 2009
- Thoracoabdominal-Aortoiliac Multidetector-Row CT Angiography at 80 and 100 kVpInvestigative Radiology, 2009
- Computed Tomography — An Increasing Source of Radiation ExposureNew England Journal of Medicine, 2007
- 16-MDCT Angiography in Living Kidney Donors at Various Tube Potentials: Impact on Image Quality and Radiation DoseAmerican Journal of Roentgenology, 2007
- Cancer risks attributable to low doses of ionizing radiation: Assessing what we really knowProceedings of the National Academy of Sciences, 2003