Wearable Sweat Biosensors for Inflammatory Biomarkers (CRP, IL-6 and TNF-α): A Systematic Review of Analytical and Clinical Evidence
Authors:
- Raghad S. AlsharidahRARaghad S. Alsharidah
- Razique AnwerRazique Anwer
- Maysoon Anwar AbdelhamidMAMaysoon Anwar Abdelhamid
- Eman Amer AlanaziEAEman Amer Alanazi
- Farah Mfwadh AlanaziFAFarah Mfwadh Alanazi
- Haneen Fahaid AlanaziHAHaneen Fahaid Alanazi
- Jumanah Naif AlotaibiJAJumanah Naif Alotaibi
- Lama Abdulaziz AlshathriLALama Abdulaziz Alshathri
- Renad Ali AlshehriRARenad Ali Alshehri
- Rania AlsuhibaniRARania Alsuhibani
- Raghad H. MajrashiRMRaghad H. Majrashi
Open Access
- 18 September 2026
- journal article
- review article
- Published by MDPI AG in Biosensors
- Vol. 16 (9) , 521
Abstract
Background: Wearable sweat biosensors have emerged as a promising non-invasive approach for monitoring inflammatory biomarkers, offering an alternative to repeated blood sampling. This systematic review evaluated the current evidence on the detection of C-reactive protein (CRP), interleukin-6 (IL-6), and tumor necrosis factor-α (TNF-α) in sweat for infection and inflammatory disease monitoring. Methods: Following PRISMA 2020 guidelines (PROSPERO: CRD420261371221), PubMed/MEDLINE, Scopus, Web of Science, IEEE Xplore, and Google Scholar were searched through April 2026. Human studies measuring CRP, IL-6, or TNF-α in sweat using wearable or biosensor-based platforms were included. Risk of bias and certainty of evidence were assessed using a modified Newcastle–Ottawa Scale/JBI checklist and GRADE. Results: Thirteen studies (2020–2025, 5–80 participants) were included. CRP showed the most consistent sweat-serum agreement (r = 0.844) and good diagnostic performance in one inflammatory bowel disease cohort (AUC = 0.845). TNF-α demonstrated the highest diagnostic accuracy in a single longitudinal study (AUC = 0.962), whereas IL-6 showed moderate sweat-serum correlations (R2 = 0.60–0.72) but limited diagnostic discrimination. IL-6 and TNF-α were more consistently detected in passively collected eccrine sweat, although IL-6 was also successfully measured following pilocarpine iontophoresis in one study. Most studies had moderate methodological quality. Conclusions: Sweat-based measurement of CRP, IL-6, and TNF-α is analytically feasible for non-invasive inflammatory biomarker monitoring. However, current evidence remains limited by small, heterogeneous studies, underscoring the need for standardized protocols and larger prospective clinical validation.Keywords
This publication has 37 references indexed in Scilit:
- Development and benchtop testing of an aptamer-based sweat sensor for CRP detectionMicrochimica Acta, 2025
- Wearable, self-cleaning, ultrathin and flexible biosensor with automatic sweat processing capability for non-invasive cytokine monitoringChemical Engineering Journal, 2025
- Longitudinal tracking of chronic inflammation through Calprotectin and Interleukin-6 using a sweat wearable deviceBiosensors and Bioelectronics: X, 2025
- Economic Perspective of the Use of Wearables in Health Care: A Systematic ReviewMayo Clinic Proceedings: Digital Health, 2024
- Longitudinal monitoring of IL-6 and CRP in inflammatory bowel disease using IBD-AWAREBiosensors and Bioelectronics: X, 2024
- A wearable electrochemical fabric for cytokine monitoringBiosensors and Bioelectronics, 2023
- Novel Approach to Track the Lifecycle of Inflammation from Chemokine Expression to Inflammatory Proteins in Sweat Using Electrochemical BiosensorAdvanced Materials Technologies, 2022
- Cytokines: From Clinical Significance to QuantificationAdvanced Science, 2021
- Temporal profiling of cytokines in passively expressed sweat for detection of infection using wearable deviceBioengineering & Translational Medicine, 2021
- Rapid and Selective Biomarker Detection with Conductometric SensorsSmall, 2021