The effect of different surgical drilling procedures on full laser‐etched microgrooves surface‐treated implants: an experimental study in sheep
- 17 June 2013
- journal article
- research article
- Published by Wiley in Clinical Oral Implants Research
- Vol. 25 (9) , 1072-1077
Abstract
Objectives: To evaluate the influence of instrumentation technique on the early osseointegration histomorphometrics and biomechanical fixation of fully laser‐etched microgrooves implant surfaces in a sheep model.Material and Methods: Six sheep were subjected to bilateral hip surgeries 3 and 6 weeks before euthanasia. A total of 48 implants (∅4.5 mm, 8 mm in length) were distributed among four sites (8 per animal) and placed in bone sites drilled to 4.6 mm (reamer), 4.1 mm (loose), 3.7 mm (medium) and 3.2 mm (tight) in diameter. After healing, the animals were euthanized and half of the implants were biomechanically tested, while the remainder was subjected to non‐decalcified histologic processing. The histomorphometric parameters assessed were bone‐to‐implant contact (BIC) and bone area fraction occupancy (BAFO). Statistical analysis was performed using a mixed‐model analysis of variance with significance level set atP < 0.05.Results: A general increasing trend is present from 3 to 6 weeks for most of the variables. The groups prepared to be press fit seemed to present higher values, which were maintained throughout the observation period. The reamer group presented the lowestBICprobably due to the drilling technique; however qualitatively, more new bone seemed to be in contact to the implant surface, at 3 weeks, whereas the implants placed in press‐fit situations were mainly supported by cortical bone.Conclusion: The laser‐etched microgrooved implant presented osteoconductive and biocompatible properties for all surgical procedures tested. However, procedures providing increasingly higher press‐fit scenarios presented the strongest histomorphometric and biomechanical responses at 3 and 6 weeks.Keywords
This publication has 56 references indexed in Scilit:
- Histological and biomechanical analysis of porous additive manufactured implants made by direct metal laser sintering: A pilot study in sheepJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2013
- Osteoblast behavior on TiO2 microgrooves prepared by soft-lithography and sol–gel methodsMaterials Science and Engineering: C, 2012
- The effect of static bone strain on implant stability and bone remodelingBone, 2011
- Comparison of Er:YAG laser, piezoelectric, and drill osteotomy for dental implant site preparation: A biomechanical and histological analysis in sheepLasers in Surgery and Medicine, 2010
- The influence of nanoscale grooved substrates on osteoblast behavior and extracellular matrix depositionBiomaterials, 2010
- A study of the bone healing kinetics of plateau versus screw root design titanium dental implantsClinical Oral Implants Research, 2009
- Connective‐tissue responses to defined biomaterial surfaces. I. Growth of rat fibroblast and bone marrow cell colonies on microgrooved substratesJournal of Biomedical Materials Research Part A, 2007
- Surface treatments of titanium dental implants for rapid osseointegrationDental Materials, 2007
- Effects of multigrooved surfaces on fibroblast behaviorJournal of Biomedical Materials Research Part A, 2003
- Excimer laser surface treatment of Ti–6Al–4V alloy for corrosion resistance enhancementMaterials Letters, 2002