Improved sensitivity and temporal resolution in perfusion FMRI using velocity selective inversion ASL
- 6 September 2018
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 81 (2) , 1004-1015
Abstract
Purpose: This work aims to investigate the utility of velocity selective inversion pulses for perfusion weighted functional MRI.Methods: Tracer kinetic properties of velocity selective inversion (VSI) pulses as an input function for an arterial spin labeling (ASL) experiment were characterized in a group of healthy participants. Numerical simulations were conducted to search for a robust set of timing parameters for FMRI time series acquisition with maximal signal to noise ratio efficiency. The performance of three VSI pulse sequences with different timing parameters was compared with a pseudocontinuous ASL sequence in a simple FMRI experiment conducted on healthy participants.Results: The fit to the tracer kinetic model yielded arterial CBV of 1.24% ± 0.52% and 0.45 ± 0.11% and perfusion rates of 60.8 ± 32.3 and 34.4 ± 5.4 mL/min/100 g for gray and white matter, respectively. Bolus arrival times were estimated as 75.7 ± 21 ms and 349 ± 78 ms for gray and white matter, respectively. The FMRI experiments showed that VSI pulses yield comparable sensitivity to PCASL with similar timing parameters (TR = 4 s). However, VSI pulses could be used at a faster acquisition speed (TR = 3 s) and were more sensitive to neuronal activity than PCASL pulses, as evidenced by the 31% higher Z scores obtained on average in the active regions.Conclusion: VSI pulses can be very beneficial for perfusion weighted functional MRI because of their tracer kinetic characteristics, which allow a faster acquisition rate while maintaining an efficient labeling input function.Keywords
Funding Information
- National Institute of Biomedical Imaging and Bioengineering (R21EB021562)
- National Institutes of Health (R21EB021562)
This publication has 29 references indexed in Scilit:
- Perfusion by Arterial Spin labelling following Single dose Tadalafil In Small vessel disease (PASTIS): study protocol for a randomised controlled trialTrials, 2017
- Quantifying the changes in oxygen extraction fraction and cerebral activity caused by caffeine and acetazolamideJournal of Cerebral Blood Flow & Metabolism, 2016
- Cerebral blood flow MRI in the nondemented elderly is not predictive of post-operative delirium but is correlated with cognitive performanceJournal of Cerebral Blood Flow & Metabolism, 2016
- Recommended implementation of arterial spin‐labeled perfusion MRI for clinical applications: A consensus of the ISMRM perfusion study group and the European consortium for ASL in dementiaMagnetic Resonance in Medicine, 2014
- The development and future of perfusion fMRI for dynamic imaging of human brain activityNeuroImage, 2012
- Challenges to attention: A continuous arterial spin labeling (ASL) study of the effects of distraction on sustained attentionNeuroImage, 2011
- Velocity‐selective arterial spin labelingMagnetic Resonance in Medicine, 2006
- Perfusion fMRI for Functional Neuroimaging2005
- Experimental Design and the Relative Sensitivity of BOLD and Perfusion fMRINeuroImage, 2002
- Velocity Selective Radiofrequency Pulse TrainsJournal of Magnetic Resonance, 1999