Luis Hernandez-Garcia
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Luis Hernandez-Garcia has a total of 123 co-authors. Here are the top co-authors by number of shared publications:
- Joseph Woods
Oxford Centre for Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical Neurosciences University of Oxford Oxford UK
6 shared publications - Matthias J. P. van Osch
Department of Radiology Leiden University Medical Center Leiden The Netherlands
5 shared publications - Moss Y. Zhao
Department of Neurosurgery, Stanford University, Stanford, CA, United States
5 shared publications - Qin Qin
Russell H. Morgan Department of Radiology and Radiological Science Johns Hopkins University School of Medicine Baltimore Maryland USA
5 shared publications David C. Alsop
Department of Radiology Beth Israel Deaconess Medical Center and Harvard Medical School Boston Massachusetts USA
4 shared publicationsGreg Zaharchuk
Department of Radiology Stanford University Stanford California USA
4 shared publications
Latest Publications
- Open Access
- 10 December 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 95 (5) , 2568-2579
Velocity Spectrum Imaging Using Velocity Encoding Preparation Pulses
Purpose: The goal of this article is to introduce a technique to measure the velocity distribution of water inside each voxel of an MR image. The method is based on the use of motion sensitizing gradients with changing first moment to encode velocity. As such, it is completely non‐invasive and requires no contrast injections. Methods: The technique consists of acquiring a series of images preceded by preparatory RF pulses that encode velocity information, analogously to k‐space encoding. The velocity distribution can be decoded via the Fourier transform. We demonstrate its use on a simple flow phantom with known flow characteristics. We demonstrate the technique on the brains of five human participants from whom we collected the velocity distribution along each of the three laboratory axes. Results: Velocity distribution measurements on simple phantoms yielded velocity distributions consistent with theory. Human velocity spectra identified specific anatomical features at different velocity bins. The largest fraction of spins was in the lowest velocity bands. Movement in the CSF spaces could be clearly identified at different velocity bands. Conclusion: Velocity Spectrum Imaging has great potential as a tool to study the movement of fluids in the human body without contrast agents. In addition to a useful tool for validating computational fluid dynamic models in vivo, it can be used to study the complex movement of water in the glymphatic system and its involvement in neurodegenerative disorders. However, further development is needed to probe the velocity spectrum in the ultra‐low velocity regime of the perivascular spaces.
- 10 December 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 95 (5) , 2568-2579
Open AccessVelocity Spectrum Imaging Using Velocity Encoding Preparation Pulses
Purpose: The goal of this article is to introduce a technique to measure the velocity distribution of water inside each voxel of an MR image. The method is based on the use of motion sensitizing gradients with changing first moment to encode velocity. As such, it is completely non‐invasive and requires no contrast injections. Methods: The technique consists of acquiring a series of images preceded by preparatory RF pulses that encode velocity information, analogously to k‐space encoding. The velocity distribution can be decoded via the Fourier transform. We demonstrate its use on a simple flow phantom with known flow characteristics. We demonstrate the technique on the brains of five human participants from whom we collected the velocity distribution along each of the three laboratory axes. Results: Velocity distribution measurements on simple phantoms yielded velocity distributions consistent with theory. Human velocity spectra identified specific anatomical features at different velocity bins. The largest fraction of spins was in the lowest velocity bands. Movement in the CSF spaces could be clearly identified at different velocity bands. Conclusion: Velocity Spectrum Imaging has great potential as a tool to study the movement of fluids in the human body without contrast agents. In addition to a useful tool for validating computational fluid dynamic models in vivo, it can be used to study the complex movement of water in the glymphatic system and its involvement in neurodegenerative disorders. However, further development is needed to probe the velocity spectrum in the ultra‐low velocity regime of the perivascular spaces.
- 23 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Computational Imaging
- Vol. 11 (25730436) , 1534-1547
Convergent Complex Quasi-Newton Proximal Methods for Gradient-Driven Denoisers in Compressed Sensing MRI Reconstruction
In compressed sensing (CS) MRI, model-based methods are pivotal to achieving accurate reconstruction. One of the main challenges in model-based methods is finding an effective prior to describe the statistical distribution of the target image. Plug-and-Play (PnP) and REgularization by Denoising (RED) are two general frameworks that use denoisers as the prior. While PnP/RED methods with convolutional neural network (CNN) based denoisers outperform classical hand-crafted priors in CS MRI, their convergence theory relies on assumptions that do not hold for practical CNN models. The recently developed gradient-driven denoisers offer a framework that bridges the gap between practical performance and theoretical guarantees. However, the numerical solvers for the associated minimization problem remain slow for CS MRI reconstruction. This paper proposes a complex quasi-Newton proximal method that achieves faster convergence than existing approaches. To address the complex domain in CS MRI, we propose a modified Hessian estimation method that guarantees Hermitian positive definiteness. Furthermore, we provide a rigorous convergence analysis of the proposed method for nonconvex settings. Numer ical experiments on both Cartesian and non-Cartesian sampling trajectories demonstrate the effectiveness and efficiency of our approach.
- 23 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Computational Imaging
- Vol. 11 (25730436) , 1534-1547
Convergent Complex Quasi-Newton Proximal Methods for Gradient-Driven Denoisers in Compressed Sensing MRI Reconstruction
In compressed sensing (CS) MRI, model-based methods are pivotal to achieving accurate reconstruction. One of the main challenges in model-based methods is finding an effective prior to describe the statistical distribution of the target image. Plug-and-Play (PnP) and REgularization by Denoising (RED) are two general frameworks that use denoisers as the prior. While PnP/RED methods with convolutional neural network (CNN) based denoisers outperform classical hand-crafted priors in CS MRI, their convergence theory relies on assumptions that do not hold for practical CNN models. The recently developed gradient-driven denoisers offer a framework that bridges the gap between practical performance and theoretical guarantees. However, the numerical solvers for the associated minimization problem remain slow for CS MRI reconstruction. This paper proposes a complex quasi-Newton proximal method that achieves faster convergence than existing approaches. To address the complex domain in CS MRI, we propose a modified Hessian estimation method that guarantees Hermitian positive definiteness. Furthermore, we provide a rigorous convergence analysis of the proposed method for nonconvex settings. Numer ical experiments on both Cartesian and non-Cartesian sampling trajectories demonstrate the effectiveness and efficiency of our approach.
- 31 May 2025
- Published by Springer Nature
- p. 31-71
Introduction to Functional MRI Hardware
- Top Cited PapersOpen Access
- 9 April 2024
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 92 (2) , 469-495
Recommendations for quantitative cerebral perfusion MRI using multi‐timepoint arterial spin labeling: Acquisition, quantification, and clinical applications
Accurate assessment of cerebral perfusion is vital for understanding the hemodynamic processes involved in various neurological disorders and guiding clinical decision‐making. This guidelines article provides a comprehensive overview of quantitative perfusion imaging of the brain using multi‐timepoint arterial spin labeling (ASL), along with recommendations for its acquisition and quantification. A major benefit of acquiring ASL data with multiple label durations and/or post‐labeling delays (PLDs) is being able to account for the effect of variable arterial transit time (ATT) on quantitative perfusion values and additionally visualize the spatial pattern of ATT itself, providing valuable clinical insights. Although multi‐timepoint data can be acquired in the same scan time as single‐PLD data with comparable perfusion measurement precision, its acquisition and postprocessing presents challenges beyond single‐PLD ASL, impeding widespread adoption. Building upon the 2015 ASL consensus article, this work highlights the protocol distinctions specific to multi‐timepoint ASL and provides robust recommendations for acquiring high‐quality data. Additionally, we propose an extended quantification model based on the 2015 consensus model and discuss relevant postprocessing options to enhance the analysis of multi‐timepoint ASL data. Furthermore, we review the potential clinical applications where multi‐timepoint ASL is expected to offer significant benefits. This article is part of a series published by the International Society for Magnetic Resonance in Medicine (ISMRM) Perfusion Study Group, aiming to guide and inspire the advancement and utilization of ASL beyond the scope of the 2015 consensus article.
- 9 April 2024
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 92 (2) , 469-495
Top Cited PapersOpen AccessRecommendations for quantitative cerebral perfusion MRI using multi‐timepoint arterial spin labeling: Acquisition, quantification, and clinical applications
Accurate assessment of cerebral perfusion is vital for understanding the hemodynamic processes involved in various neurological disorders and guiding clinical decision‐making. This guidelines article provides a comprehensive overview of quantitative perfusion imaging of the brain using multi‐timepoint arterial spin labeling (ASL), along with recommendations for its acquisition and quantification. A major benefit of acquiring ASL data with multiple label durations and/or post‐labeling delays (PLDs) is being able to account for the effect of variable arterial transit time (ATT) on quantitative perfusion values and additionally visualize the spatial pattern of ATT itself, providing valuable clinical insights. Although multi‐timepoint data can be acquired in the same scan time as single‐PLD data with comparable perfusion measurement precision, its acquisition and postprocessing presents challenges beyond single‐PLD ASL, impeding widespread adoption. Building upon the 2015 ASL consensus article, this work highlights the protocol distinctions specific to multi‐timepoint ASL and provides robust recommendations for acquiring high‐quality data. Additionally, we propose an extended quantification model based on the 2015 consensus model and discuss relevant postprocessing options to enhance the analysis of multi‐timepoint ASL data. Furthermore, we review the potential clinical applications where multi‐timepoint ASL is expected to offer significant benefits. This article is part of a series published by the International Society for Magnetic Resonance in Medicine (ISMRM) Perfusion Study Group, aiming to guide and inspire the advancement and utilization of ASL beyond the scope of the 2015 consensus article.
- 23 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Computational Imaging
- Vol. 10 (25730436) , 372-384
A Complex Quasi-Newton Proximal Method for Image Reconstruction in Compressed Sensing MRI
Model-based methods are widely used for reconstruction in compressed sensing (CS) magnetic resonance imaging (MRI), using regularizers to describe the images of interest. The reconstruction process is equivalent to solving a composite optimization problem. Accelerated proximal methods (APMs) are very popular approaches for such problems. This paper proposes a complex quasi-Newton proximal method (CQNPM) for the wavelet and total variation based CS MRI reconstruction. Compared with APMs, CQNPM requires fewer iterations to converge but needs to compute a more challenging proximal mapping called weighted proximal mapping (WPM). To make CQNPM more practical, we propose efficient methods to solve the related WPM. Numerical experiments on reconstructing non-Cartesian MRI data demonstrate the effectiveness and efficiency of CQNPM.
- 23 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Computational Imaging
- Vol. 10 (25730436) , 372-384
A Complex Quasi-Newton Proximal Method for Image Reconstruction in Compressed Sensing MRI
Model-based methods are widely used for reconstruction in compressed sensing (CS) magnetic resonance imaging (MRI), using regularizers to describe the images of interest. The reconstruction process is equivalent to solving a composite optimization problem. Accelerated proximal methods (APMs) are very popular approaches for such problems. This paper proposes a complex quasi-Newton proximal method (CQNPM) for the wavelet and total variation based CS MRI reconstruction. Compared with APMs, CQNPM requires fewer iterations to converge but needs to compute a more challenging proximal mapping called weighted proximal mapping (WPM). To make CQNPM more practical, we propose efficient methods to solve the related WPM. Numerical experiments on reconstructing non-Cartesian MRI data demonstrate the effectiveness and efficiency of CQNPM.
- 6 February 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 89 (6) , 2305-2317
Comparison and optimization of pCASL and VSASL for rat thoracolumbar spinal cord MRI at 9.4 T
Purpose To evaluate pseudo-continuous arterial spin labeling (pCASL) and velocity-selective arterial spin labeling (VSASL) for quantification of spinal cord blood flow (SCBF) in the rat thoracolumbar spinal cord.Methods Labeling efficiency (LE) was compared between pCASL and three VSASL variants in simulations and both phantom and in vivo experiments at 9.4 T. For pCASL, the effects of label plane position and shimming were systematically evaluated. For VSASL, the effects of composite pulses and phase cycling were evaluated to reduce artifacts. Additionally, vessel suppression, respiratory, and cardiac gating were evaluated to reduce motion artifacts. pCASL and VSASL maps of spinal cord blood flow were acquired with the optimized protocols.Results LE of the descending aorta was larger in pCASL compared to VSASL variants. In pCASL, LE off-isocenter was improved by local shimming positioned at the label plane and the anatomical level of labeling for the thoracic cord was only viable at the level of the T10 vertebra. Cardiac gating was essential to reduce motion artifacts. Both pCASL and VSASL successfully demonstrated comparable SCBF values in the thoracolumbar cord.Conclusion pCASL demonstrated high and consistent LE in the thoracic aorta, and VSASL was also feasible, but with reduced efficiency. A combination of cardiac gating and recording of actual post-label delays was important for accurate SCBF quantification. These results highlight the challenges and solutions to achieve sufficient ASL labeling and contrast at high field in organs prone to motion.
- 6 February 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 89 (6) , 2305-2317
Comparison and optimization of pCASL and VSASL for rat thoracolumbar spinal cord MRI at 9.4 T
Purpose To evaluate pseudo-continuous arterial spin labeling (pCASL) and velocity-selective arterial spin labeling (VSASL) for quantification of spinal cord blood flow (SCBF) in the rat thoracolumbar spinal cord.Methods Labeling efficiency (LE) was compared between pCASL and three VSASL variants in simulations and both phantom and in vivo experiments at 9.4 T. For pCASL, the effects of label plane position and shimming were systematically evaluated. For VSASL, the effects of composite pulses and phase cycling were evaluated to reduce artifacts. Additionally, vessel suppression, respiratory, and cardiac gating were evaluated to reduce motion artifacts. pCASL and VSASL maps of spinal cord blood flow were acquired with the optimized protocols.Results LE of the descending aorta was larger in pCASL compared to VSASL variants. In pCASL, LE off-isocenter was improved by local shimming positioned at the label plane and the anatomical level of labeling for the thoracic cord was only viable at the level of the T10 vertebra. Cardiac gating was essential to reduce motion artifacts. Both pCASL and VSASL successfully demonstrated comparable SCBF values in the thoracolumbar cord.Conclusion pCASL demonstrated high and consistent LE in the thoracic aorta, and VSASL was also feasible, but with reduced efficiency. A combination of cardiac gating and recording of actual post-label delays was important for accurate SCBF quantification. These results highlight the challenges and solutions to achieve sufficient ASL labeling and contrast at high field in organs prone to motion.
- 24 November 2022
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 89 (3) , 1278-1279
Erratum to: Velocity‐selective arterial spin labeling perfusion MRI: A review of the state of the art and recommendations for clinical implementation (Magn Reson Med. 2022; 88:1528–1547)
- 24 November 2022
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 89 (3) , 1278-1279
Erratum to: Velocity‐selective arterial spin labeling perfusion MRI: A review of the state of the art and recommendations for clinical implementation (Magn Reson Med. 2022; 88:1528–1547)
- Open Access
- 6 September 2022
- Published by Springer Nature in Scientific Data
- Vol. 9 (1) , 1-8
ASL-BIDS, the brain imaging data structure extension for arterial spin labeling
Arterial spin labeling (ASL) is a non-invasive MRI technique that allows for quantitative measurement of cerebral perfusion. Incomplete or inaccurate reporting of acquisition parameters complicates quantification, analysis, and sharing of ASL data, particularly for studies across multiple sites, platforms, and ASL methods. There is a strong need for standardization of ASL data storage, including acquisition metadata. Recently, ASL-BIDS, the BIDS extension for ASL, was developed and released in BIDS 1.5.0. This manuscript provides an overview of the development and design choices of this first ASL-BIDS extension, which is mainly aimed at clinical ASL applications. Discussed are the structure of the ASL data, focussing on storage order of the ASL time series and implementation of calibration approaches, unit scaling, ASL-related BIDS fields, and storage of the labeling plane information. Additionally, an overview of ASL-BIDS compatible conversion and ASL analysis software and ASL example datasets in BIDS format is provided. We anticipate that large-scale adoption of ASL-BIDS will improve the reproducibility of ASL research.
- 6 September 2022
- Published by Springer Nature in Scientific Data
- Vol. 9 (1) , 1-8
Open AccessASL-BIDS, the brain imaging data structure extension for arterial spin labeling
Arterial spin labeling (ASL) is a non-invasive MRI technique that allows for quantitative measurement of cerebral perfusion. Incomplete or inaccurate reporting of acquisition parameters complicates quantification, analysis, and sharing of ASL data, particularly for studies across multiple sites, platforms, and ASL methods. There is a strong need for standardization of ASL data storage, including acquisition metadata. Recently, ASL-BIDS, the BIDS extension for ASL, was developed and released in BIDS 1.5.0. This manuscript provides an overview of the development and design choices of this first ASL-BIDS extension, which is mainly aimed at clinical ASL applications. Discussed are the structure of the ASL data, focussing on storage order of the ASL time series and implementation of calibration approaches, unit scaling, ASL-related BIDS fields, and storage of the labeling plane information. Additionally, an overview of ASL-BIDS compatible conversion and ASL analysis software and ASL example datasets in BIDS format is provided. We anticipate that large-scale adoption of ASL-BIDS will improve the reproducibility of ASL research.
- Open Access
- 19 August 2022
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 88 (5) , 2021-2042
Recent Technical Developments in ASL: A Review of the State of the Art
This review article provides an overview of a range of recent technical developments in advanced arterial spin labeling (ASL) methods that have been developed or adopted by the community since the publication of a previous ASL consensus paper by Alsop et al. It is part of a series of review/recommendation papers from the International Society for Magnetic Resonance in Medicine Perfusion Study Group. Here, we focus on advancements in readouts and trajectories, image reconstruction, noise reduction, partial volume correction, quantification of nonperfusion parameters, fMRI, fingerprinting, vessel selective ASL, angiography, deep learning, and ultrahigh field ASL. We aim to provide a high level of understanding of these new approaches and some guidance for their implementation, with the goal of facilitating the adoption of such advances by research groups and by MRI vendors. Topics outside the scope of this article that are reviewed at length in separate articles include velocity selective ASL, multiple‐timepoint ASL, body ASL, and clinical ASL recommendations.
- 19 August 2022
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 88 (5) , 2021-2042
Open AccessRecent Technical Developments in ASL: A Review of the State of the Art
This review article provides an overview of a range of recent technical developments in advanced arterial spin labeling (ASL) methods that have been developed or adopted by the community since the publication of a previous ASL consensus paper by Alsop et al. It is part of a series of review/recommendation papers from the International Society for Magnetic Resonance in Medicine Perfusion Study Group. Here, we focus on advancements in readouts and trajectories, image reconstruction, noise reduction, partial volume correction, quantification of nonperfusion parameters, fMRI, fingerprinting, vessel selective ASL, angiography, deep learning, and ultrahigh field ASL. We aim to provide a high level of understanding of these new approaches and some guidance for their implementation, with the goal of facilitating the adoption of such advances by research groups and by MRI vendors. Topics outside the scope of this article that are reviewed at length in separate articles include velocity selective ASL, multiple‐timepoint ASL, body ASL, and clinical ASL recommendations.