Effects of inaccurate small field dose measurements on calculated treatment doses
- 5 July 2016
- journal article
- scientific note
- Published by Springer Nature in Australasian Physics & Engineering Sciences in Medicine
- Vol. 39 (3) , 747-753
Abstract
Given the difficulty and potential time- or financial-costs associated with accurate small field dosimetry, this study aimed to establish the clinical necessity of obtaining accurate small field output factor measurements and to evaluate the effects on planned doses that could arise if accurate measurements are not used in treatment planning dose calculations. Isocentre doses, in heterogeneous patient anatomy, were calculated and compared for 571 beams from 48 clinical radiotherapy treatments, using a clinical radiotherapy treatment planning system, with reference to two different sets of beam configuration data. One set of beam configuration data included field output factors (total scatter factors) from precisely positioned and response-corrected diode measurements and the other included field output factors measured using a conventional technique that would have been better suited to larger field measurements. Differences between the field output factor measurements made with the two different techniques equated to 14.2 % for the 6 \(\times\) 6 mm\(^2\) field, 1.8 % for the 12 \(\times\) 12 mm\(^2\) field, and less than 0.5 % for the larger fields. This led to isocentre dose differences of up to 3.3 % in routine clinical fields smaller than 9 mm across and and up to 11 % in convoluted fields smaller than 15 mm across. If field widths smaller than 15 mm are used clinically, then accurate measurement (or-remeasurement) of small field output factors in the treatment planning system’s beam data is required in order to achieve dose calculation accuracy within 3 %. If such measurements are not completed, then errors in excess of 10 % may occur if very small, narrow, concave or convoluted treatment fields are used.
Keywords
Funding Information
- Australian Research Council (LP110100401)
This publication has 28 references indexed in Scilit:
- Dosimetry of cone‐defined stereotactic radiosurgery fields with a commercial synthetic diamond detectorMedical Physics, 2014
- Characterizing the influence of detector density on dosimeter response in non-equilibrium small photon fieldsPhysics in Medicine & Biology, 2012
- Experimental comparison of seven commercial dosimetry diodes for measurement of stereotactic radiosurgery cone factorsMedical Physics, 2011
- Stereotactic body radiation therapy: The report of AAPM Task Group 101Medical Physics, 2010
- Total scatter factors of small beams: A multidetector and Monte Carlo studyMedical Physics, 2008
- Small fields: Nonequilibrium radiation dosimetryMedical Physics, 2007
- Commissioning stereotactic radiosurgery beams using both experimental and theoretical methodsPhysics in Medicine & Biology, 2006
- A new approach in dose measurement and error analysis for narrow photon beams (beamlets) shaped by different multileaf collimators using a small detectorMedical Physics, 2004
- The volume effect of detectors in the dosimetry of small fields used in IMRTMedical Physics, 2003
- Total scatter factors and tissue maximum ratios for small radiosurgery fields: Comparison of diode detectors, a parallel‐plate ion chamber, and radiographic filmMedical Physics, 2000