Accuracy of Two Digital Scanners (Intraoral, Extraoral) Compared to Conventional Impression Using Implant with Different Angulations (Zero, 15°,25°) “In-Vitro Study”
Open Access
- 1 December 2024
- journal article
- research article
- Published by Egyptian Knowledge Bank in Journal of Fundamental and Clinical Research
- Vol. 4 (2) , 172-188
Abstract
Background: Achieving passive fit for implant-supported restorations on multiple abutments with varied implant angulations is challenging with conventional impressions due to distortion. Digital scanning offers potential for greater accuracy in such cases. Aim of the study: To evaluate intraoral and extraoral scanners' accuracy compared to conventional impressions across different implant angulations (0°, 15°, 25°). Materials and Methods: Three epoxy models with implants at various angles were scanned by InEos X5 for reference. Conventional PVS impressions (n=15), scanning with intraoral Primescan (n=15), and extraoral Trios 3shape (n=15) were tested. Impressions were converted to STL format and analyzed for trueness and precision using digital control surface matching software GeoMagic Control X. Statistical analysis was conducted using two-way ANOVA. Results: Significant statistical differences were found among the groups, with Trios desktop scanner exhibiting the best trueness and precision (p < 0.001), followed by Primescan IOS and PVS impressions. Implant angulation significantly influenced trueness (p < 0.001), with higher deviations at 25°, followed by 15° and 0°, except for Primescan IOS, where no statistically significant difference was found between 15° and 0° angulations. Conclusion: parallel implants have the best accuracy in terms of trueness and precision. The use of desktop scanners offers the highest accuracy regardless of the implant angulations.Keywords
This publication has 34 references indexed in Scilit:
- Accuracy of tooth‐implant impressions: Comparison of five different techniquesClinical and Experimental Dental Research, 2023
- Accuracy of intraoral scans: An in vivo study of different scanning devicesThe Journal of Prosthetic Dentistry, 2022
- Accuracy of digital impressions for three-unit and four-unit implant supported fixed dental prostheses using a novel deviceJournal of Dental Sciences, 2022
- Accuracy of impressions for multiple implants: A comparative study of digital and conventional techniquesThe Journal of Prosthetic Dentistry, 2022
- Additive manufacturing technologies: Industrial and medical applicationsSustainable Operations and Computers, 2022
- Comparison of conventional, photogrammetry, and intraoral scanning accuracy of complete-arch implant impression procedures evaluated with a coordinate measuring machineThe Journal of Prosthetic Dentistry, 2021
- Accuracy of full-arch digital impressions: an in vitro and in vivo comparisonClinical Oral Investigations, 2019
- Restoring severely angled implants with custom abutments and a screw-retained fixed dental prosthesisJournal of Dental Sciences, 2019
- Dental Implants: The Last 100 YearsJournal of Oral and Maxillofacial Surgery, 2018
- Comparison of repeatability between intraoral digital scanner and extraoral digital scanner: An in-vitro studyJournal of Prosthodontic Research, 2015