LGLomaya Ghanem

Lomaya Ghanem

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Lomaya Ghanem has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Digital versus Conventional Methods of Wear Analysis Using Two Different Hybrid Ceramic Materials: In-Vitro Study

    by Fady Samy Labib Elsharouny, Tamer Hamza, Lomaya Ghanem

    Background: Hybrid ceramic materials have been introduced resemble natural teeth appearance and behavior allowing minimal reduction using modified preparation techniques. Their wear behavior against natural teeth is still under investigation. Aim of the study: This present study aims to compare wear analysis using both conventional and digital methods regarding two hybrid ceramic materials against natural tooth antagonists. Materials and methods: A total of 26 Samples fabricated from Vita Emanic and Cerasmart 270 (n=13 each) were cut into discs of 2mm thickness and 10mm diameter, then tested for wear using conventional and digital techniques. All samples were subjected to chewing simulation. Conventional wear testing was carried out by evaluating weight loss before and after chewing simulation. Digital wear testing was carried out by using Geomagic software from superimposing scan images before and after chewing simulation. Scans were first obtained through Medit T710 desktop scanner. The generated data was collected and analyzed. Results: A positive correlation was found between conventional and digital measurements. There was a statistically significant difference between both materials in wear behavior. In both weight loss and digital superimposition methods, Vita Enamic displayed significantly higher amount of wear than Cerasmart 270 (p < 0.001); weight Vita Enamic and Cerasmart 270 respectively (22.12±3.41mg) (12.10±2.92mg), and RMS Vita Enamic and Cerasmart 270 respectively (0.82±0.24 µm), (0.52±0.15µm). Conclusion: Both conventional weight loss and digital volume loss can be used as reliable methods for assessing wear. Cerasmart 270 is more wear resistant than Vita Enamic.Keywords: Wear, Conventional wear analysis, Digital wear analysis, Hybrid ceramics.

  • Open Access

    Microleakage of Gradient Versus Translucent Monolithic Zirconia crowns bonded with Self-Adhesive Resin Cement.

    by Maro Faltas, Lomaya Ghanem, Ashraf Mokhtar

    Background: One of the most influencing factors on the clinical longevity of indirect restorations is marginal microleakage. Presence of marginal gap results in exposure of the cement at the margins and its dissolution, followed by secondary caries, periodontal disease and microleakage. Data regarding microleakage of gradient monolithic zirconia have been deficient. Aim of the study: To assess the microleakage of monolithic crowns made of gradient zirconia (IPS E-max ZirCAD Prime, Ivoclar) compared to crowns made of Translucent 5Y zirconia (UTML,Katana) bonded with self-adhesive resin cement (Theracem,Bisco). Materials and methods: Sixteen monolithic zirconia crowns were constructed using the CAD/CAM system and divided randomly into two equal groups according to the type of zirconia. Group I: ZirCAD Prime crowns (n=8), while group II: UTML zirconia single crowns (n=8). Both groups were bonded with Theracem self-adhesive resin cement (Bisco) to 16 extracted first premolar teeth. After cementation, the teeth were subjected to thermocycling for 5000 cycles at changing temperature between 5°C and 55°C. The microleakage was measured by immersing the samples in 0.5% basic fuschin dye for 48 hours at 37℃. After the dye penetration, the crowns were sectioned vertically by Isomet Saw in a bucco-lingual direction to measure microleakage using stereomicroscope at 40X magnification. Results: There was no significant difference between leakage scores of the two tested groups. Conclusion: Both Groups fell within micro leakage scoring 1 &3 which indicated the extension of the dye only within the finish line area.

  • Open Access

    Effect of Cyclic Loading on The Fracture Resistance of Bilayered 3Y-TZP and Monolithic Gradient 5Y-TZP/3Y-TZP Zirconia Based Fixed Partial Denture. (In-Vitro Study)

    by Rana Negm, Tamer Shokry, Lomaya Ghanem

    Aim of the Study: This study aims to measure the fracture resistance of a four-unit fixed partial denture constructed from gradient monolithic zirconia 3Y-TZP/5Y-TZP compared to bilayered zirconia 3Y-TZP four-unit fixed partial denture.Background: Developments in dental materials have led to the creation of an innovative strength-gradient zirconia, which merges 3-mol% yttria-stabilized tetragonal zirconia polycrystal (3Y-TZP) with 5-mol% yttria-stabilized tetragonal zirconia polycrystal (5Y-TZP). Despite these advancements, there is a lack of information on its fracture resistance behavior. Material and Methods: A standardized stainless-steel master die was designed to replicate a mandibular first premolar and second molar, prepared to receive 4-unit monolithic and bilayered zirconia FPDs. Ten zirconia fixed partial dentures were milled and divided into two groups (n=5): one with 3Y-TZP that was layered by 0.4 mm ceramic veneer, the other group is monolithic gradient zirconia 5Y-TZP and 3Y-TZP. The FPDs underwent cyclic loading in a mastication simulator to simulate six months of clinical use then fracture resistance was measured using a universal testing machine at a crosshead speed of 1 mm/min, and fractographic analysis was conducted using a scanning electron microscope. Results: The highest statistically significant fracture load was recorded in monolithic 5Y-TZP and 3Y-TZP gradient zirconia (844 ± 156 N), while the lowest statistically significant fracture load was recorded in bilayered zirconia 3Y-TZP (601 ± 89 N). Conclusion: The fracture strength of 4-unit gradient multilayered zirconia 5Y-TZP/3Y-TZP was significantly higher than bilayered zirconia 3Y-TZP when both were subjected to fracture resistance tests after mastication simulation.


  • Open Access

    Accuracy of Two Digital Scanners (Intraoral, Extraoral) Compared to Conventional Impression Using Implant with Different Angulations (Zero, 15°,25°) “In-Vitro Study”

    by Kirollos Ashraf Rafla, Rana Mahmoud Sherif, Lomaya Ghanem

    Background: Achieving passive fit for implant-supported restorations on multiple abutments with varied implant angulations is challenging with conventional impressions due to distortion. Digital scanning offers potential for greater accuracy in such cases. Aim of the study: To evaluate intraoral and extraoral scanners' accuracy compared to conventional impressions across different implant angulations (0°, 15°, 25°). Materials and Methods: Three epoxy models with implants at various angles were scanned by InEos X5 for reference. Conventional PVS impressions (n=15), scanning with intraoral Primescan (n=15), and extraoral Trios 3shape (n=15) were tested. Impressions were converted to STL format and analyzed for trueness and precision using digital control surface matching software GeoMagic Control X. Statistical analysis was conducted using two-way ANOVA. Results: Significant statistical differences were found among the groups, with Trios desktop scanner exhibiting the best trueness and precision (p < 0.001), followed by Primescan IOS and PVS impressions. Implant angulation significantly influenced trueness (p < 0.001), with higher deviations at 25°, followed by 15° and 0°, except for Primescan IOS, where no statistically significant difference was found between 15° and 0° angulations. Conclusion: parallel implants have the best accuracy in terms of trueness and precision. The use of desktop scanners offers the highest accuracy regardless of the implant angulations.


  • Open Access

    Effect of different intraoral scanners and post-space depths on the trueness of digital impressions

    by Marwa Emam, Lomaya Ghanem, Hoda Sadek

    The trueness of intraoral scanners (IOSs) has been evaluated in many clinical situations. However, the tests of their performance when scanning post-space preparations are still lacking. The aim of the present study was to compare the trueness of the digital impressions of post spaces with different depths, captured by means of different IOSs. Digital impressions of teeth (N = 16) with post spaces of depths of 8 mm and 10 mm were captured. Three IOSs were used, including Primescan AC, Medit i500 and CS 3600. The STL files were compared to the files obtained from the traditional impression scanning performed with an InEos X5 desktop scanner. Then, reverse engineering software measured the trueness values, which were analyzed using the two-way analysis of variance (ANOVA), followed by Tukey's post-hoc test. The significance level was set at p < 0.05. Significant differences were found between the scanners in terms of root mean square (RMS) values (p < 0.001). The highest RMS value was found for CS 3600 (0.30 ±0.11 mm), followed by Primescan AC (0.26 ±0.09 mm), while the lowest value was found for Medit i500 (0.18 ±0.05 mm). The 8-millimeter-deep post spaces had a significantly higher RMS value than the 10-millimeter-deep ones (0.28 ±0.10 mm and 0.21 ±0.09 mm, respectively) (p = 0.009). The Medit i500 scanner showed the highest post-space digital impression trueness as compared to Primescan AC and CS 3600. In the digital impressions captured with CS 3600, the 10 mm postspace depth had higher trueness than the 8 mm depth. Moreover, CS 3600 was less able to capture the full length of both the 8 mm and 10 mm post-space depths than Primescan AC and Medit i500.


  • Open Access

    Wear and Surface Roughness of 3D Printed and Milled CAD-CAM Restorative Materials

    by Ahmed Mohamed Arafa, Lomaya Ghanem

    Purpose: to assess wear behavior and surface roughness of CAD-CAM restorative materials and their opposing enamel antagonists. Materials and methods: Rectangular-shaped specimens (n=22) (14×12×1.5 mm) were prepared; 3D printed VarseoSmile Crown plus (VS) (n=11) and milled brilliant crios (BC) (n=11). Both groups were finished with composite polishing kit. Wear testing was performed in chewing simulator with twenty-two freshly extracted mandibular premolars antagonists. The wear of specimens and opposing enamel antagonists was calculated by weight loss. The surface roughness (Ra) of the specimens and their opposing enamel antagonist was analyzed by using a digital image analysis software at baseline and after chewing simulation then inspected by SEM. Data were statistically analyzed using Paired t-test, Independent t-test, and Chi square test (p = 0.05). Results: A significant weight loss in tested groups and their opposing enamel antagonists after chewing simulation was noticed by Paired t-test (p < 0.05) where insignificant percentage change of weight between tested groups (p = 0.93) and between their antagonists (p = 0.79) was noticed by Chi square test. Also, A significant difference in Ra value after chewing simulation between tested groups was noticed (p < 0.05) where insignificant percentage change in Ra value between tested groups (p =0.74) and between their antagonists (p = 0.88) was noticed by Chi square test. Conclusions: Based on their properties, each material was affected by chewing simulation at different intensities; The tested CAD-CAM restorative materials and their opposing enamel antagonists showed wear demonstrated by weight loss and difference in surface roughness.


  • Open Access

    Clinical and Radiographic Evaluation of Crown Margin Shifting Concept: A New Technique for Re-establishing the Biological Width

    by Sarah Hussein, Nayer Aboelsaad, Nasser Hussein, Lomaya Ghanem, Maha Fouad

    Objective: To evaluate an innovative approach, Crown Margin Shifting (CMS), for its ability to re-establish the biological width (BW) or supracrestal tissue attachment. Clinical considerations: Seven patients aged between 25-45 years old, presented with bilateral maxillary premolars with deep interproximal caries violating the BW were recruited for this study. Both study sites received monolithic zirconia crowns with heavy chamfer finish line. The heavy chamfer is thicker and with bevel on the deepest part of experiment site. Clinical parameters were evaluated at baseline, 6 and 12 months after. Radiographic evaluation using CBCT was done to measure marginal bone loss (MBL) and the established BW at the deep proximal finish line. Results revealed significant improvement in Modified Plaque Index (MBI) and Gingival Index (GI) parameters in both sites at the end of the study. The Periodontal Probing Depth (PPD) increased significantly in the first 6 months only for both. The marginal bone loss (MBL) was present in control site throughout the 12 months, whereas in CMS site, it took place only in the first 6 months. Conclusions: The results support that CMS approach had less radiographic marginal bone loss without a negative influence on the clinical parameters up to one year follow-up.

  • Open Access

    Marginal Fit of PMMA CAD/CAM Crowns Fabricated by using Photogrammetry Scanning method. (an invitro study)

    by Mostafa Kamel, Ali Elkady, Lomaya Ghanem

    Purpose. The aim of this study was to assess the marginal accuracy of provisional CAD/CAM PMMA crowns fabricated by two-dimensional image-based rendering (IBR) photogrammetry scanning method. Materials and Methods. 10 epoxy resin dies, duplicated from an anatomically reduced maxillary central incisor. Epoxy dies were distributed into two groups according to the method of die scanning (n=5). Gp I the dies were scanned with extraoral desktop scanner. For Gp II photogrammetry scanning for the dies was done using standardized photos using a professional digital single reflex (DSLR) camera for photo acquisition. Photography technique was standardized using a custom-made device to ensure adequate overlap between acquired photos, further rendering of photos was done using specialized photogrammetry software. Produced standardized tessellation Language (STL) files from both scanning methods were used for fabrication of CAD/CAM Polymethylmethacrylate crowns. Mean vertical marginal gap of crowns fabricated by both scanning methods was measured using stereomicroscope at 20 equidistant points (5 points in each surface), and results were statistically analysed using paired t-test. Results. Mean marginal gap for Gp I (extraoral scanner) was (106.3 + 12.3 microns), while for Gp II (photogrammetry scanning) mean marginal gap was (99.6 + 28.3 microns). There was no statistically significant difference between marginal gap distances measurement by extraoral scanner and photogrammetry scanning method (p>0.05). produced marginal accuracy results were within the clinically acceptable range below 120 µ. Conclusion. Photogrammetry scanning image-based rendering can be an affordable and reliable method to fabricate CAD/CAM crowns with proper marginal accuracy.