Risk Factors for Exposure, Pain, and Dyspareunia After Tension-Free Vaginal Mesh Procedure
Authors:
- Mariëlla I. WithagenMWMariëlla I. Withagen
- Mark E. VierhoutMVMark E. Vierhout
- Jan C. HendriksJHJan C. Hendriks
- Kirsten B. KluiversKKKirsten B. Kluivers
- Alfredo L. MilaniAMAlfredo L. Milani
- 1 September 2011
- journal article
- research article
- Published by Wolters Kluwer Health in Obstetrics & Gynecology
- Vol. 118 (3) , 629-636
Abstract
To identify possible risk factors for exposure, dyspareunia, and pain after insertion of tension-free vaginal mesh in pelvic organ prolapse surgery. This was a prospective observational cohort study. Consecutive women who underwent surgery with a trocar-guided tension-free vaginal mesh kit were included and evaluated at 6 weeks and at 6 and 12 months after surgery with respect to anatomy and complications. Logistic regression analysis was performed to identify risk factors for exposure, dyspareunia, and pain. Two hundred ninety-four patients were included. Exposure was found in 34 patients (12%). Smoking and total mesh were risk factors for exposure (odds ratio [OR] 3.1, 95% confidence interval [CI] 1.1-8.7 and OR 3.0, 95% CI 1.2-7.0, respectively). Clinical and surgical experience were inversely related to the risk of exposure (OR 0.5, 95% CI 0.3-0.8 per decade). Pain (OR 3.2, 95% CI 1.2-8.4) and dyspareunia (OR 4.7, 95% CI 1.7-12.8) before surgery were predictive for pain and dyspareunia after surgery, respectively. Pain after surgery was found in 35 out of 275 (13%) patients and dyspareunia was found in 77 out of 171 (45%) patients. Smoking, total tension-free vaginal mesh, and experience were predictive factors for mesh exposure.Keywords
This publication has 22 references indexed in Scilit:
- Trocar-Guided Mesh Compared With Conventional Vaginal Repair in Recurrent ProlapseObstetrics & Gynecology, 2011
- An international urogynecological association (IUGA)/international continence society (ICS) joint terminology and classification of the complications related directly to the insertion of prostheses (meshes, implants, tapes) and grafts in female pelvic floor surgeryNeurourology and Urodynamics, 2010
- Symptomatic pelvic organ prolapse and possible risk factors in a general populationAmerican Journal of Obstetrics and Gynecology, 2009
- Review of synthetic mesh-related complications in pelvic floor reconstructive surgeryInternational Urogynecology Journal, 2008
- The ability of endometrial biopsies with atypical complex hyperplasia to guide surgical managementAmerican Journal of Obstetrics and Gynecology, 2008
- Outcome After Anterior Vaginal Prolapse RepairObstetrics & Gynecology, 2008
- Surgical management of pelvic organ prolapse in women: A short version Cochrane reviewNeurourology and Urodynamics, 2007
- Transvaginal mesh technique for pelvic organ prolapse repair: mesh exposure management and risk factorsInternational Urogynecology Journal, 2005
- Epidemiology of surgically managed pelvic organ prolapse and urinary incontinenceObstetrics & Gynecology, 1997
- The efficacy of Marlex mesh in the repair of severe, recurrent vaginal prolapse of the anterior midvaginal wallAmerican Journal of Obstetrics and Gynecology, 1996