Abstract
Purpose: To optimize imaging parameters for balanced turbo field echo (BTFE) sequence combined with motion-sensitized driven equilibrium (MSDE) preparation for endoleak detection and type classification in phantom experiments. Materials and Methods: We prepared four phantoms: a pulsatile flow generator with an aortic aneurysm model simulating no endoleak, and a type-1, type-2, and type-3 endoleak. Throughout the experiments, MSDE-BTFE images with and without flow suppression were obtained at 1.5 T and subtraction images were used for image evaluation. The no-endoleak phantom was imaged using different MSDE-BTFE sequences to optimize the k-space trajectory and evaluate the use of electrocardiogram gating. The relative contrast between flowing saline and background was calculated. Then all phantoms were imaged to determine the optimal velocity encoding (VENC) for endoleak detection and type classification. Three independent observers performed the image evaluation. Consistencies between the interpreted and true results were analyzed using kappa statistics. Results: The 3D low-high k-space trajectory with electrocardiogram gating provided the highest relative contrast. Low VENCs of 2–10 cm/s and high VENCs of 20 cm/s showed perfect consistency in endoleaks detection and type classification, respectively. Conclusion: MSDE-BTFE sequences of appropriate VENCs has potential for endoleak detection and type classification, without contrast material. J. Magn. Reson. Imaging 2013;38:714–721.Keywords
This publication has 30 references indexed in Scilit:
- Prospective intraindividual comparison of unenhanced magnetic resonance imaging vs contrast-enhanced computed tomography for the planning of endovascular abdominal aortic aneurysm repairJournal of Vascular Surgery, 2012
- Non‐contrast‐enhanced vascular magnetic resonance imaging using flow‐dependent preparation with subtractionMagnetic Resonance in Medicine, 2011
- Accuracy and repeatability of fourier velocity encoded M‐mode and two‐dimensional cine phase contrast for pulse wave velocity measurement in the descending aortaJournal of Magnetic Resonance Imaging, 2010
- 3D noncontrast MR angiography of the distal lower extremities using flow‐sensitive dephasing (FSD)‐prepared balanced SSFPMagnetic Resonance in Medicine, 2009
- Improved arterial visibility using short‐tau inversion‐recovery (STIR) fat suppression in non‐contrast‐enhanced time–spatial labeling inversion pulse (Time‐SLIP) renal MR angiography (MRA)Journal of Magnetic Resonance Imaging, 2009
- Renal Consequences of Endovascular Abdominal Aortic Aneurysm RepairJournal of Endovascular Therapy, 2008
- Improved suppression of plaque‐mimicking artifacts in black‐blood carotid atherosclerosis imaging using a multislice motion‐sensitized driven‐equilibrium (MSDE) turbo spin‐echo (TSE) sequenceMagnetic Resonance in Medicine, 2007
- Diffusion-Prepared Segmented Steady-State Free Precession: Application to 3D Black-Blood Cardiovascular Magnetic Resonance of the Thoracic Aorta and Carotid Artery WallsJournal of Cardiovascular Magnetic Resonance, 2007
- MRI Versus Helical CT for Endoleak Detection After Endovascular Aneurysm RepairAmerican Journal of Roentgenology, 2005
- Coronary Angiography with Magnetization‐Prepared T2 ContrastMagnetic Resonance in Medicine, 1995