Off-Pump Atrial Septal Defect Closure Using the Universal Cardiac Introducer®
- 1 January 2009
- journal article
- research article
- Published by SAGE Publications in Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery
- Vol. 4 (1) , 20-26
Abstract
Objective: Optimal atrial septal defect (ASD) closure should combine off-pump techniques with the effectiveness and versatility of open-heart techniques. We report our experience with off-pump ASD closure using the Universal Cardiac Introducer (UCI) in a porcine model. The goal was to create an ASD over the fossa ovale (FO) and position a patch over the ASD under ultrasound (US) imaging and augmented virtual reality guidance. Methods: An US probe (tracked with a magnetic tracking system) was positioned into the esophagus (transesophageal echocardiographic probe) for real-time image-guidance. The right atrium (RA) of six pigs was exposed via a right lateral thoracotomy or medial sternotomy. The UCI was attached to the RA wall. A punching tool was introduced via the UCI, navigated and positioned, under US guidance, to create an ASD into the FO. A patch with its holder and a stapling device were introduced into the RA via the UCI. The patch was positioned on the ASD. Occlusion of the ASD was determined using US and Doppler imaging. Results: The FO membrane was excised successfully in all animals. US image-guidance provided excellent visualization. The patch was positioned in all cases with complete occlusion of the ASD. The stapling device proved too bulky, impeding circumferential positioning. Conclusions: Using the UCI, ASD closure was safe and feasible. US imaging, combined with virtual and augmented reality provided accurate navigating and positioning. This study also provided valuable information on the future design of anchoring devices for intracardiac procedures.Keywords
This publication has 32 references indexed in Scilit:
- Embolization of an Amplatzer Atrial Septal Closure Device to the Pulmonary ArteryJournal of Cardiac Surgery, 2008
- Transcatheter Cardiac Fistula Repair with the Amplatzer Duct Occluder: A Case Report and ReviewJournal of Interventional Cardiology, 2007
- Incidence of aortic valve regurgitation and outcome after percutaneous closure of atrial septal defects and patent foramen ovaleHeart, 2007
- Surgical atrial septal defect closure after interventional occluder placement: Incidence and outcomeThe Journal of Thoracic and Cardiovascular Surgery, 2007
- Three-dimensional echo-guided beating heart surgery without cardiopulmonary bypass: Atrial septal defect closure in a swine modelThe Journal of Thoracic and Cardiovascular Surgery, 2005
- Thoracoscopic ASD closure is a reliable supplement for percutaneous treatmentHeart, 2005
- Erosion of Amplatzer septal occluder device after closure of secundum atrial septal defects: Review of registry of complications and recommendations to minimize future riskCatheterization and Cardiovascular Interventions, 2004
- Transcatheter closure of atrial septal defect in young childrenJACC, 2003
- Cardiopulmonary Bypass to Repair an Atrial Septal Defect Does Not Affect Cognitive Function in ChildrenCirculation, 2003
- ATRIAL SEPTAL DEFECT AND ITS SURGICAL TREATMENTThe Lancet, 1957