Estimation of intraocular pressure in normal canine eyes utilizing the newly introduced TonoVet Plus and TonoPen Avia, and their comparison to the established TonoVet
Authors:
- 10 March 2020
- journal article
- research article
- Published by Wiley in Veterinary Ophthalmology
- Vol. 24 (S1) , 171-174
Abstract
Purpose: To evaluate the IOP values obtained from normal canine eyes, by means of the TonoVet Plus (TVP) and TonoPen Avia (TPA), and compare them to an established tonometer, the TonoVet (TV).Methods: Tonometry was performed bilaterally in 50 healthy dogs, age 1‐11 years. The rebound tonometers (TV and TVP) were used first (in a random order), and then, one drop of tetracaine hydrochloride was applied to each eye, and approximately one minute later the IOP was estimated using the TPA. The mean ± standard deviation (SD) was calculated for each tonometer and a paired Student'sttest was used to compare the IOP values between tonometers. APvalue ≤ .05 was considered significant. The agreement between tonometers was assessed by a Bland‐Altman plot.Results: The mean ± SD (range) IOP values were 15.0 ± 3.2 mm Hg (7‐22), 19.2 ± 3.1 mm Hg (11‐25), and 12.8 ± 2.9 mm Hg (6‐19), for the TV, TVP, and TPA, respectively. The IOP values obtained by each tonometer were significantly different compared to the other two (P < .0001). There was a good agreement with fixed bias between all tonometers.Conclusions: The average IOP values of the TVP were significantly higher than those of the TV, which were significantly higher than those of the TPA, in normal canine eyes. Knowing the normal IOP values for these tonometers and the bias between them will help the clinician with the interpretation of IOP values obtained by these devices and compare between them.Keywords
This publication has 8 references indexed in Scilit:
- Evaluation of three hand-held tonometers in normal canine eyesThe Veterinary Journal, 2017
- Evaluation of a rebound tonometer (Tonovet®) in clinically normal cat eyesVeterinary Ophthalmology, 2010
- Comparison of the rebound tonometer (ICare®) to the applanation tonometer (Tonopen XL®) in normotensive dogsVeterinary Ophthalmology, 2006
- Comparison of the use of new handheld tonometers and established applanation tonometers in dogsAmerican Journal of Veterinary Research, 2006
- Evaluation of a rebound tonometer for measuring intraocular pressure in dogs and horsesJournal of the American Veterinary Medical Association, 2005
- A new induction‐based impact method for measuring intraocular pressureActa Ophthalmologica Scandinavica, 2000
- Evaluation of three applanation tonometers in dogsAmerican Journal of Veterinary Research, 1990
- Über ApplanationstonometrieOphthalmologica, 1957