Real-Time Tracheal Ultrasound vs. Capnography for Intubation Confirmation during CPR Wearing a Powered Air-Purifying Respirator in COVID-19 Era
Authors:
Open Access
- 21 January 2024
- journal article
- research article
- Published by MDPI AG in Diagnostics
- Vol. 14 (2) , 225
Abstract
This study aimed to compare the accuracy of real-time trans-tracheal ultrasound (TTUS) with capnography to confirm intubation in cardiopulmonary resuscitation (CPR) while wearing a powered air-purifying respirator (PAPR). This setting reflects increased caution due to contagious diseases. This single-center, prospective, comparative study enrolled patients requiring CPR while wearing a PAPR who visited the emergency department of a tertiary medical center from December 2020 to August 2022. A physician performed the TTUS in real time and recorded the tube placement assessment. Another healthcare provider attached waveform capnography to the tube and recorded end-tidal carbon dioxide (EtCO2) after five ventilations. The accuracy and agreement of both methods compared with direct laryngoscopic visualization of tube placement, and the time taken by both methods was evaluated. Thirty-three patients with cardiac arrest were analyzed. TTUS confirmed tube placement with 100% accuracy, sensitivity, and specificity, whereas capnography demonstrated 97% accuracy, 96.8% sensitivity, and 100% specificity. The Kappa values for TTUS and capnography compared to direct visualization were 1.0 and 0.7843, respectively. EtCO2 was measured in 45 (37–59) seconds (median (interquartile range)), whereas TTUS required only 12 (8–23) seconds, indicating that TTUS was significantly faster (p < 0.001). No significant correlation was found between the physician’s TTUS proficiency and image acquisition time. This study demonstrated that TTUS is more accurate and faster than EtCO2 measurement for confirming endotracheal tube placement during CPR, particularly in the context of PAPR usage in pandemic conditions.Keywords
Funding Information
- National Research Foundation of Korea (NRF-2022R1C1C1011864)
This publication has 30 references indexed in Scilit:
- Real-time tracheal ultrasonography for confirmation of endotracheal tube placement during cardiopulmonary resuscitationResuscitation, 2013
- Ultrasound, tracheal intubation and cardiopulmonary resuscitation: Isn’t there enough to do during a cardiac arrest?Resuscitation, 2013
- The comparison of airway ultrasonography and continuous waveform capnography to confirm endotracheal tube placement in cardiac arrest patients: prospective observational studyThe Ultrasound Journal, 2012
- Ultrasound instead of capnometry for confirming tracheal tube placement in an emergency?Resuscitation, 2011
- Tracheal rapid ultrasound exam (T.R.U.E.) for confirming endotracheal tube placement during emergency intubationResuscitation, 2011
- Emergency Ultrasound GuidelinesAnnals of Emergency Medicine, 2009
- Confirmation of Endotracheal Tube Placement after Intubation Using the Ultrasound Sliding Lung SignAcademic Emergency Medicine, 2006
- Verification of endotracheal tube placement with colorimetric end-tidal CO2 detectionAnnals of Emergency Medicine, 1991
- Assessment of Routine Chest Roentgenograms and the Physical Examination to Confirm Endotracheal Tube PositionChest, 1989