Se Uk Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Se Uk Lee has a total of 53 co-authors. Here are the top co-authors by number of shared publications:
- Sung Yeon Hwang
Department of Emergency Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 06351, Republic of Korea
11 shared publications - Gun Tak Lee
Department of Emergency Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 06351, Republic of Korea
10 shared publications - Hee Yoon
Department of Emergency Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 06351, Republic of Korea
10 shared publications - Jong Eun Park
Department of Emergency Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 06351, Republic of Korea
10 shared publications - Tae Gun Shin
Department of Emergency Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea
10 shared publications - Taerim Kim
Department of Emergency Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea
10 shared publications
Latest Publications
- Open Access
- 3 May 2024
- Published by Wolters Kluwer Health in Medicine
- Vol. 103  (18) , e38026
Status and perception of point-of-care ultrasound education in Korean medical schools: A national cross-sectional study
As point-of-care ultrasound (POCUS) is increasingly being used in clinical settings, ultrasound education is expanding into student curricula. We aimed to determine the status and awareness of POCUS education in Korean medical schools using a nationwide cross-sectional survey. In October 2021, a survey questionnaire consisting of 20 questions was distributed via e-mail to professors in the emergency medicine (EM) departments of Korean medical schools. The questionnaire encompassed 19 multiple-choice questions covering demographics, current education, perceptions, and barriers, and the final question was an open-ended inquiry seeking suggestions for POCUS education. All EM departments of the 40 medical schools responded, of which only 13 (33%) reported providing POCUS education. The implementation of POCUS education primarily occurred in the third and fourth years, with less than 4 hours of dedicated training time. Five schools offered a hands-on education. Among schools offering ultrasound education, POCUS training for trauma cases is the most common. Eight schools had designated professors responsible for POCUS education and only 2 possessed educational ultrasound devices. Of the respondents, 64% expressed the belief that POCUS education for medical students is necessary, whereas 36%, including those with neutral opinions, did not anticipate its importance. The identified barriers to POCUS education included faculty shortages (83%), infrastructure limitations (76%), training time constraints (74%), and a limited awareness of POCUS (29%). POCUS education in Korean medical schools was limited to a minority of EM departments (33%). To successfully implement POCUS education in medical curricula, it is crucial to clarify learning objectives, enhance faculty recognition, and improve the infrastructure. These findings provide valuable insights for advancing ultrasound training in medical schools to ensure the provision of high-quality POCUS education for future healthcare professionals.
- 3 May 2024
- Published by Wolters Kluwer Health in Medicine
- Vol. 103  (18) , e38026
Open AccessStatus and perception of point-of-care ultrasound education in Korean medical schools: A national cross-sectional study
As point-of-care ultrasound (POCUS) is increasingly being used in clinical settings, ultrasound education is expanding into student curricula. We aimed to determine the status and awareness of POCUS education in Korean medical schools using a nationwide cross-sectional survey. In October 2021, a survey questionnaire consisting of 20 questions was distributed via e-mail to professors in the emergency medicine (EM) departments of Korean medical schools. The questionnaire encompassed 19 multiple-choice questions covering demographics, current education, perceptions, and barriers, and the final question was an open-ended inquiry seeking suggestions for POCUS education. All EM departments of the 40 medical schools responded, of which only 13 (33%) reported providing POCUS education. The implementation of POCUS education primarily occurred in the third and fourth years, with less than 4 hours of dedicated training time. Five schools offered a hands-on education. Among schools offering ultrasound education, POCUS training for trauma cases is the most common. Eight schools had designated professors responsible for POCUS education and only 2 possessed educational ultrasound devices. Of the respondents, 64% expressed the belief that POCUS education for medical students is necessary, whereas 36%, including those with neutral opinions, did not anticipate its importance. The identified barriers to POCUS education included faculty shortages (83%), infrastructure limitations (76%), training time constraints (74%), and a limited awareness of POCUS (29%). POCUS education in Korean medical schools was limited to a minority of EM departments (33%). To successfully implement POCUS education in medical curricula, it is crucial to clarify learning objectives, enhance faculty recognition, and improve the infrastructure. These findings provide valuable insights for advancing ultrasound training in medical schools to ensure the provision of high-quality POCUS education for future healthcare professionals.
- Open Access
- 21 January 2024
- Published by MDPI AG in Diagnostics
- Vol. 14  (2) , 225
Real-Time Tracheal Ultrasound vs. Capnography for Intubation Confirmation during CPR Wearing a Powered Air-Purifying Respirator in COVID-19 Era
This study aimed to compare the accuracy of real-time trans-tracheal ultrasound (TTUS) with capnography to confirm intubation in cardiopulmonary resuscitation (CPR) while wearing a powered air-purifying respirator (PAPR). This setting reflects increased caution due to contagious diseases. This single-center, prospective, comparative study enrolled patients requiring CPR while wearing a PAPR who visited the emergency department of a tertiary medical center from December 2020 to August 2022. A physician performed the TTUS in real time and recorded the tube placement assessment. Another healthcare provider attached waveform capnography to the tube and recorded end-tidal carbon dioxide (EtCO2) after five ventilations. The accuracy and agreement of both methods compared with direct laryngoscopic visualization of tube placement, and the time taken by both methods was evaluated. Thirty-three patients with cardiac arrest were analyzed. TTUS confirmed tube placement with 100% accuracy, sensitivity, and specificity, whereas capnography demonstrated 97% accuracy, 96.8% sensitivity, and 100% specificity. The Kappa values for TTUS and capnography compared to direct visualization were 1.0 and 0.7843, respectively. EtCO2 was measured in 45 (37–59) seconds (median (interquartile range)), whereas TTUS required only 12 (8–23) seconds, indicating that TTUS was significantly faster (p < 0.001). No significant correlation was found between the physician’s TTUS proficiency and image acquisition time. This study demonstrated that TTUS is more accurate and faster than EtCO2 measurement for confirming endotracheal tube placement during CPR, particularly in the context of PAPR usage in pandemic conditions.
- 21 January 2024
- Published by MDPI AG in Diagnostics
- Vol. 14  (2) , 225
Open AccessReal-Time Tracheal Ultrasound vs. Capnography for Intubation Confirmation during CPR Wearing a Powered Air-Purifying Respirator in COVID-19 Era
This study aimed to compare the accuracy of real-time trans-tracheal ultrasound (TTUS) with capnography to confirm intubation in cardiopulmonary resuscitation (CPR) while wearing a powered air-purifying respirator (PAPR). This setting reflects increased caution due to contagious diseases. This single-center, prospective, comparative study enrolled patients requiring CPR while wearing a PAPR who visited the emergency department of a tertiary medical center from December 2020 to August 2022. A physician performed the TTUS in real time and recorded the tube placement assessment. Another healthcare provider attached waveform capnography to the tube and recorded end-tidal carbon dioxide (EtCO2) after five ventilations. The accuracy and agreement of both methods compared with direct laryngoscopic visualization of tube placement, and the time taken by both methods was evaluated. Thirty-three patients with cardiac arrest were analyzed. TTUS confirmed tube placement with 100% accuracy, sensitivity, and specificity, whereas capnography demonstrated 97% accuracy, 96.8% sensitivity, and 100% specificity. The Kappa values for TTUS and capnography compared to direct visualization were 1.0 and 0.7843, respectively. EtCO2 was measured in 45 (37–59) seconds (median (interquartile range)), whereas TTUS required only 12 (8–23) seconds, indicating that TTUS was significantly faster (p < 0.001). No significant correlation was found between the physician’s TTUS proficiency and image acquisition time. This study demonstrated that TTUS is more accurate and faster than EtCO2 measurement for confirming endotracheal tube placement during CPR, particularly in the context of PAPR usage in pandemic conditions.
- Open Access
- 30 December 2023
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 14  (1) , 57
A Simple Bacteremia Score for Predicting Bacteremia in Patients with Suspected Infection in the Emergency Department: A Cohort Study
Bacteremia is a life-threatening condition that has increased in prevalence over the past two decades. Prompt recognition of bacteremia is important; however, identification of bacteremia requires 1 to 2 days. This retrospective cohort study, conducted from 10 November 2014 to November 2019, among patients with suspected infection who visited the emergency department (ED), aimed to develop and validate a simple tool for predicting bacteremia. The study population was randomly divided into derivation and development cohorts. Predictors of bacteremia based on the literature and logistic regression were assessed. A weighted value was assigned to predictors to develop a prediction model for bacteremia using the derivation cohort; discrimination was then assessed using the area under the receiver operating characteristic curve (AUC). Among the 22,519 patients enrolled, 18,015 were assigned to the derivation group and 4504 to the validation group. Sixteen candidate variables were selected, and all sixteen were used as significant predictors of bacteremia (model 1). Among the sixteen variables, the top five with higher odds ratio, including procalcitonin, neutrophil–lymphocyte ratio (NLR), lactate level, platelet count, and body temperature, were used for the simple bacteremia score (model 2). The proportion of bacteremia increased according to the simple bacteremia score in both cohorts. The AUC for model 1 was 0.805 (95% confidence interval [CI] 0.785–0.824) and model 2 was 0.791 (95% CI 0.772–0.810). The simple bacteremia prediction score using only five variables demonstrated a comparable performance with the model including sixteen variables using all laboratory results and vital signs. This simple score is useful for predicting bacteremia-assisted clinical decisions.
- 30 December 2023
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 14  (1) , 57
Open AccessA Simple Bacteremia Score for Predicting Bacteremia in Patients with Suspected Infection in the Emergency Department: A Cohort Study
Bacteremia is a life-threatening condition that has increased in prevalence over the past two decades. Prompt recognition of bacteremia is important; however, identification of bacteremia requires 1 to 2 days. This retrospective cohort study, conducted from 10 November 2014 to November 2019, among patients with suspected infection who visited the emergency department (ED), aimed to develop and validate a simple tool for predicting bacteremia. The study population was randomly divided into derivation and development cohorts. Predictors of bacteremia based on the literature and logistic regression were assessed. A weighted value was assigned to predictors to develop a prediction model for bacteremia using the derivation cohort; discrimination was then assessed using the area under the receiver operating characteristic curve (AUC). Among the 22,519 patients enrolled, 18,015 were assigned to the derivation group and 4504 to the validation group. Sixteen candidate variables were selected, and all sixteen were used as significant predictors of bacteremia (model 1). Among the sixteen variables, the top five with higher odds ratio, including procalcitonin, neutrophil–lymphocyte ratio (NLR), lactate level, platelet count, and body temperature, were used for the simple bacteremia score (model 2). The proportion of bacteremia increased according to the simple bacteremia score in both cohorts. The AUC for model 1 was 0.805 (95% confidence interval [CI] 0.785–0.824) and model 2 was 0.791 (95% CI 0.772–0.810). The simple bacteremia prediction score using only five variables demonstrated a comparable performance with the model including sixteen variables using all laboratory results and vital signs. This simple score is useful for predicting bacteremia-assisted clinical decisions.
- Open Access
- 13 November 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12  (22) , 7055
Effect of Blade Size on the First-Pass Success Rate of Endotracheal Intubation Using the C-MAC Video Laryngoscope
We sought to determine whether blade size influences the first-pass success (FPS) rate when performing endotracheal intubation (ETI) with a C-MAC video laryngoscope (VL) in emergency department (ED) patients. This single-center, retrospective, observational study was conducted between August 2016 and July 2022. A total of 1467 patients was divided into two categories based on the blade size used during the first ETI attempt: blade-3 (n = 365) and blade-4 groups (n = 1102). The primary outcome was the FPS rate. The secondary outcomes included the glottic view, multiple attempt rate, and ETI-related complications. We used propensity score matching to reduce the potential confounders between the two groups. Among these, 363 pairs of matched propensity scores were generated. The FPS rate did not differ between the blade-3 (84.8%) and blade-4 groups (87.3%) in the matched cohort (p = 0.335). The multiple attempt rate did not differ significantly between groups (p = 0.289) and was 3.9% and 2.5% in the blade-3 and blade-4 groups, respectively. The difficult glottic view (11.3 vs. 6.9%, p = 0.039) and complication rates (15.4% vs. 10.5%, p = 0.047) were significantly higher in the blade-3 group than in the blade-4 group. The FPS rates of ETI with the blade-3 and blade-4 groups in adult patients in the ED did not differ significantly.
- 13 November 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12  (22) , 7055
Open AccessEffect of Blade Size on the First-Pass Success Rate of Endotracheal Intubation Using the C-MAC Video Laryngoscope
We sought to determine whether blade size influences the first-pass success (FPS) rate when performing endotracheal intubation (ETI) with a C-MAC video laryngoscope (VL) in emergency department (ED) patients. This single-center, retrospective, observational study was conducted between August 2016 and July 2022. A total of 1467 patients was divided into two categories based on the blade size used during the first ETI attempt: blade-3 (n = 365) and blade-4 groups (n = 1102). The primary outcome was the FPS rate. The secondary outcomes included the glottic view, multiple attempt rate, and ETI-related complications. We used propensity score matching to reduce the potential confounders between the two groups. Among these, 363 pairs of matched propensity scores were generated. The FPS rate did not differ between the blade-3 (84.8%) and blade-4 groups (87.3%) in the matched cohort (p = 0.335). The multiple attempt rate did not differ significantly between groups (p = 0.289) and was 3.9% and 2.5% in the blade-3 and blade-4 groups, respectively. The difficult glottic view (11.3 vs. 6.9%, p = 0.039) and complication rates (15.4% vs. 10.5%, p = 0.047) were significantly higher in the blade-3 group than in the blade-4 group. The FPS rates of ETI with the blade-3 and blade-4 groups in adult patients in the ED did not differ significantly.
- Open Access
- 19 July 2023
- Published by MDPI AG in Diagnostics
- Vol. 13  (14) , 2412
A Pilot Study Evaluating LV Diastolic Function with M-Mode Measurement of Mitral Valve Movement in the Parasternal Long Axis View
This pilot study aimed to develop a new, reliable, and easy-to-use method for the evaluation of diastolic function through the M-mode measurement of mitral valve (MV) movement in the parasternal long axis (PSLA), similar to E-point septal separation (EPSS) used for systolic function estimation. Thirty healthy volunteers from a tertiary emergency department (ED) underwent M-mode measurements of the MV anterior leaflet in the PSLA view. EPSS, A-point septal separation (APSS), A-point opening length (APOL), and E-point opening length (EPOL) were measured in the PSLA view, along with the E and A velocities and e’ velocity in the apical four-chamber view. Correlation analyses were performed to assess the relationship between M-mode and Doppler measurements, and the measurement time was evaluated. No significant correlations were found between M-mode and Doppler measurements in the study. However, M-mode measurements exhibited high reproducibility and faster acquisition, and the EPOL value consistently exceeded the APOL value, resembling the E and A pattern. These findings suggest that visually assessing the M-mode pattern on the MV anterior leaflet in the PSLA view may be a practical approach to estimating diastolic function in the ED. Further investigations with a larger and more diverse patient population are needed to validate these findings.
- 19 July 2023
- Published by MDPI AG in Diagnostics
- Vol. 13  (14) , 2412
Open AccessA Pilot Study Evaluating LV Diastolic Function with M-Mode Measurement of Mitral Valve Movement in the Parasternal Long Axis View
This pilot study aimed to develop a new, reliable, and easy-to-use method for the evaluation of diastolic function through the M-mode measurement of mitral valve (MV) movement in the parasternal long axis (PSLA), similar to E-point septal separation (EPSS) used for systolic function estimation. Thirty healthy volunteers from a tertiary emergency department (ED) underwent M-mode measurements of the MV anterior leaflet in the PSLA view. EPSS, A-point septal separation (APSS), A-point opening length (APOL), and E-point opening length (EPOL) were measured in the PSLA view, along with the E and A velocities and e’ velocity in the apical four-chamber view. Correlation analyses were performed to assess the relationship between M-mode and Doppler measurements, and the measurement time was evaluated. No significant correlations were found between M-mode and Doppler measurements in the study. However, M-mode measurements exhibited high reproducibility and faster acquisition, and the EPOL value consistently exceeded the APOL value, resembling the E and A pattern. These findings suggest that visually assessing the M-mode pattern on the MV anterior leaflet in the PSLA view may be a practical approach to estimating diastolic function in the ED. Further investigations with a larger and more diverse patient population are needed to validate these findings.
- 14 February 2023
- Published by Elsevier in The American Journal of Emergency Medicine
- Vol. 67, 90-96
Clinical factors predicting return emergency department visits in chemotherapy-induced febrile neutropenia patients
- 14 February 2023
- Published by Elsevier in The American Journal of Emergency Medicine
- Vol. 67, 90-96
Clinical factors predicting return emergency department visits in chemotherapy-induced febrile neutropenia patients
- Open Access
- 14 October 2022
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 12  (10) , 1720
Endotracheal Intubation Using C-MAC Video Laryngoscope vs. Direct Laryngoscope While Wearing Personal Protective Equipment
This study sought to determine whether the C-MAC video laryngoscope (VL) performed better than a direct laryngoscope (DL) when attempting endotracheal intubation (ETI) in the emergency department (ED) while wearing personal protective equipment (PPE). This was a retrospective single-center observational study conducted in an academic ED between February 2020 and March 2022. All emergency medical personnel who participated in any ETI procedure were required to wear PPE. The patients were divided into the C-MAC VL group and the DL group based on the device used during the first ETI attempt. The primary outcome measure was the first-pass success (FPS) rate. A multiple logistic regression was used to determine the factors associated with FPS. Of the 756 eligible patients, 650 were assigned to the C-MAC group and 106 to the DL group. The overall FPS rate was 83.5% (n = 631/756). The C-MAC group had a significantly higher FPS rate than the DL group (85.7% vs. 69.8%, p < 0.001). In the multivariable logistic regression analysis, C-MAC use was significantly associated with an increased FPS rate (adjusted odds ratio, 2.86; 95% confidence interval, 1.69–4.08; p < 0.001). In this study, we found that the FPS rate of ETI was significantly higher when the C-MAC VL was used than when a DL was used by emergency physicians constrained by cumbersome PPE.
- 14 October 2022
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 12  (10) , 1720
Open AccessEndotracheal Intubation Using C-MAC Video Laryngoscope vs. Direct Laryngoscope While Wearing Personal Protective Equipment
This study sought to determine whether the C-MAC video laryngoscope (VL) performed better than a direct laryngoscope (DL) when attempting endotracheal intubation (ETI) in the emergency department (ED) while wearing personal protective equipment (PPE). This was a retrospective single-center observational study conducted in an academic ED between February 2020 and March 2022. All emergency medical personnel who participated in any ETI procedure were required to wear PPE. The patients were divided into the C-MAC VL group and the DL group based on the device used during the first ETI attempt. The primary outcome measure was the first-pass success (FPS) rate. A multiple logistic regression was used to determine the factors associated with FPS. Of the 756 eligible patients, 650 were assigned to the C-MAC group and 106 to the DL group. The overall FPS rate was 83.5% (n = 631/756). The C-MAC group had a significantly higher FPS rate than the DL group (85.7% vs. 69.8%, p < 0.001). In the multivariable logistic regression analysis, C-MAC use was significantly associated with an increased FPS rate (adjusted odds ratio, 2.86; 95% confidence interval, 1.69–4.08; p < 0.001). In this study, we found that the FPS rate of ETI was significantly higher when the C-MAC VL was used than when a DL was used by emergency physicians constrained by cumbersome PPE.
- Open Access
Online Learning versus Hands-On Learning of Basic Ocular Ultrasound Skills: A Randomized Controlled Non-Inferiority Trial
Background and objectives: Ocular ultrasound is a core application of point-of-care ultrasound (POCUS) to assist physicians in promptly identifying various ocular diseases at the bedside; however, hands-on POCUS training is challenging during a pandemic. Materials and Methods: A randomized controlled non-inferiority trial was conducted in an academic emergency department from October 2020 to April 2021. Thirty-two participants were randomly assigned to one of two groups. Group H (hands-on learning group) participated individually in a hands-on session with a standardized patient for 30 min, whereas Group O (online learning group) learned training materials and video clips for 20 min. They scanned four eyeballs of two standardized patients sequentially following the ocular POCUS scan protocol. Repeated POCUS scans were performed 2 weeks later to assess skill maintenance. Both groups completed the pre- and post-surveys and knowledge tests. Two emergency medicine faculty members blindly evaluated the data and assigned a score of 0–25. The primary endpoint was the initial total score of scan quality evaluated using non-inferiority analysis (generalized estimating equation). The secondary endpoints were total scores for scan quality after 2 weeks, scan time, and knowledge test scores. Results: The least squares means of the total scores were 21.7 (0.35) for Group O and 21.3 (0.25) for Group H, and the lower bound of the 95% confidence interval (CI) was greater than the non-inferiority margin of minus 2 (95% CI: −0.48–1.17). The second scan scores were not significantly different from those of the first scan. The groups did not differ in scanning time or knowledge test results; however, Group H showed higher subjective satisfaction with the training method (p < 0.001). Conclusion: This study showed that basic online ocular ultrasound education was not inferior to hands-on education, suggesting that it could be a useful educational approach in the pandemic era.
Open AccessOnline Learning versus Hands-On Learning of Basic Ocular Ultrasound Skills: A Randomized Controlled Non-Inferiority Trial
Background and objectives: Ocular ultrasound is a core application of point-of-care ultrasound (POCUS) to assist physicians in promptly identifying various ocular diseases at the bedside; however, hands-on POCUS training is challenging during a pandemic. Materials and Methods: A randomized controlled non-inferiority trial was conducted in an academic emergency department from October 2020 to April 2021. Thirty-two participants were randomly assigned to one of two groups. Group H (hands-on learning group) participated individually in a hands-on session with a standardized patient for 30 min, whereas Group O (online learning group) learned training materials and video clips for 20 min. They scanned four eyeballs of two standardized patients sequentially following the ocular POCUS scan protocol. Repeated POCUS scans were performed 2 weeks later to assess skill maintenance. Both groups completed the pre- and post-surveys and knowledge tests. Two emergency medicine faculty members blindly evaluated the data and assigned a score of 0–25. The primary endpoint was the initial total score of scan quality evaluated using non-inferiority analysis (generalized estimating equation). The secondary endpoints were total scores for scan quality after 2 weeks, scan time, and knowledge test scores. Results: The least squares means of the total scores were 21.7 (0.35) for Group O and 21.3 (0.25) for Group H, and the lower bound of the 95% confidence interval (CI) was greater than the non-inferiority margin of minus 2 (95% CI: −0.48–1.17). The second scan scores were not significantly different from those of the first scan. The groups did not differ in scanning time or knowledge test results; however, Group H showed higher subjective satisfaction with the training method (p < 0.001). Conclusion: This study showed that basic online ocular ultrasound education was not inferior to hands-on education, suggesting that it could be a useful educational approach in the pandemic era.
- Open Access
Impact of Intubator’s Training Level on First-Pass Success of Endotracheal Intubation in Acute Care Settings: A Four-Center Retrospective Study
(1) Background: First-pass success (FPS) of endotracheal intubation is more challenging in children than in adults. We aimed to identify factors associated with FPS of intubation in acute care settings. (2) Methods: We analyzed data of children aged p = 0.018), were less frequently in their infancy (36.1% vs. 50.5%; p = 0.017), and were less likely to have respiratory compromise (41.4% vs. 55.0%; p = 0.030). The children with FPS tended to be more often intubated by experienced intubators than those without FPS (87.0% vs. 78.4%; p = 0.057). Desaturation was rarer in those with FPS. Factors associated with FPS were experienced intubators (aOR, 1.93; 95% CI, 1.01–3.67) and children’s age ≥12 months (1.84; 1.13–3.02). (4) Conclusion: FPS of intubation can be facilitated by deploying or developing clinically competent intubators, particularly for infants, in acute care settings.
Open AccessImpact of Intubator’s Training Level on First-Pass Success of Endotracheal Intubation in Acute Care Settings: A Four-Center Retrospective Study
(1) Background: First-pass success (FPS) of endotracheal intubation is more challenging in children than in adults. We aimed to identify factors associated with FPS of intubation in acute care settings. (2) Methods: We analyzed data of children aged p = 0.018), were less frequently in their infancy (36.1% vs. 50.5%; p = 0.017), and were less likely to have respiratory compromise (41.4% vs. 55.0%; p = 0.030). The children with FPS tended to be more often intubated by experienced intubators than those without FPS (87.0% vs. 78.4%; p = 0.057). Desaturation was rarer in those with FPS. Factors associated with FPS were experienced intubators (aOR, 1.93; 95% CI, 1.01–3.67) and children’s age ≥12 months (1.84; 1.13–3.02). (4) Conclusion: FPS of intubation can be facilitated by deploying or developing clinically competent intubators, particularly for infants, in acute care settings.
- Open Access
- 16 March 2022
- Published by MDPI AG in Diagnostics
- Vol. 12  (3) , 721
Use of Gallbladder Width Measurement by Computed Tomography in the Diagnosis of Acute Cholecystitis
This study aimed to evaluate the diagnostic value of gallbladder width measurement with computed tomography (CT) in patients with acute cholecystitis. This retrospective case–control study was conducted between March 2016 and March 2020 at a tertiary emergency department. Of 310 patients, 254 patients with acute cholecystitis confirmed by surgery were compared with 254 patients diagnosed with other diseases (controls). In the acute cholecystitis group, the number of older patients with underlying illnesses was much higher (64% of men). Upon CT, the median (interquartile range [IQR]) gallbladder width was significantly longer in patients with acute cholecystitis (2.26 [1.82–2.78] cm vs. 3.73 [3.32–4.16] cm, p < 0.001). The optimal cut-off value of gallbladder width for differentiating acute cholecystitis was 3.12 cm, showing a sensitivity of 88% and specificity of 86%. In a multivariable analysis using a logistic regression model for diagnosing acute cholecystitis with CT findings (gallbladder width, length, stone, wall thickening, and pericholecystic fluid), a gallbladder width of ≥3.12 cm was significantly meaningful, even when adjusting for other variables (odds ratio 37.9; p < 0.001). Therefore, an increase in gallbladder width (≥3.12 cm) measured with CT can be a simple and sensitive diagnostic sign of acute cholecystitis, supporting the underlying pathophysiology of bile outflow obstruction.
- 16 March 2022
- Published by MDPI AG in Diagnostics
- Vol. 12  (3) , 721
Open AccessUse of Gallbladder Width Measurement by Computed Tomography in the Diagnosis of Acute Cholecystitis
This study aimed to evaluate the diagnostic value of gallbladder width measurement with computed tomography (CT) in patients with acute cholecystitis. This retrospective case–control study was conducted between March 2016 and March 2020 at a tertiary emergency department. Of 310 patients, 254 patients with acute cholecystitis confirmed by surgery were compared with 254 patients diagnosed with other diseases (controls). In the acute cholecystitis group, the number of older patients with underlying illnesses was much higher (64% of men). Upon CT, the median (interquartile range [IQR]) gallbladder width was significantly longer in patients with acute cholecystitis (2.26 [1.82–2.78] cm vs. 3.73 [3.32–4.16] cm, p < 0.001). The optimal cut-off value of gallbladder width for differentiating acute cholecystitis was 3.12 cm, showing a sensitivity of 88% and specificity of 86%. In a multivariable analysis using a logistic regression model for diagnosing acute cholecystitis with CT findings (gallbladder width, length, stone, wall thickening, and pericholecystic fluid), a gallbladder width of ≥3.12 cm was significantly meaningful, even when adjusting for other variables (odds ratio 37.9; p < 0.001). Therefore, an increase in gallbladder width (≥3.12 cm) measured with CT can be a simple and sensitive diagnostic sign of acute cholecystitis, supporting the underlying pathophysiology of bile outflow obstruction.