Does Reducing CT Artifacts from Dental Implants Influence the PET Interpretation in PET/CT Studies of Oral Cancer and Head and Neck Cancer?
Authors:
- Claude NahmiasCNClaude Nahmias
- Catherine LemmensCLCatherine Lemmens
- David FaulDFDavid Faul
- Eric CarlsonECEric Carlson
- Misty LongMLMisty Long
- Todd BlodgettTBTodd Blodgett
- Johan NuytsJNJohan Nuyts
- David TownsendDTDavid Townsend
Open Access
- 13 June 2008
- journal article
- Published by Society of Nuclear Medicine in Journal of Nuclear Medicine
- Vol. 49 (7) , 1047-1052
Abstract
In patients with oral head and neck cancer, the presence of metallic dental implants produces streak artifacts in the CT images. These artifacts negate the utility of CT for the spatial localization of PET findings and may propagate through the CT-based attenuation correction into the PET images. In this study, we evaluated the efficacy of an algorithm that reduces metallic artifacts in CT images and the impact of this approach on the quantification of PET images. Methods: Fifty-one patients with and 9 without dental implants underwent a PET/CT study. CT images through the patient's dental implants were reconstructed using both standard CT reconstruction and an algorithm that reduces metallic artifacts. Attenuation correction factors were calculated from both sets of CT images and applied to the PET data. The CT images were evaluated for any reduction of the artifacts. The PET images were assessed for any quantitative change introduced by metallic artifact reduction. Results: For each reconstruction, 2 regions of interest were defined in areas where the standard CT reconstruction overestimated the Hounsfield units (HU), 2 were defined in underestimated areas, and 1 was defined in a region unaffected by the artifacts. The 5 regions of interest were transferred to the other 3 reconstructions. Mean HU or mean Bq/cm3 were obtained for all regions. In the CT reconstructions, metallic artifact reduction decreased the overestimated HUs by approximately 60% and increased the underestimated HUs by approximately 90%. There was no change in quantification in the PET images between the 2 algorithms (Spearman coefficient of rank correlation, 0.99). Although the distribution of attenuation (HU) changed considerably in the CT images, the distribution of activity did not change in the PET images. Conclusion: Our study demonstrated that the algorithm can enhance the structural and spatial content of CT images in the presence of metallic artifacts. The CT artifacts do not propagate through the CT-based attenuation correction into the PET images, confirming the robustness of CT-based attenuation correction in the presence of metallic artifacts. The study also demonstrated that considerable changes in CT images do not change the PET images.Keywords
This publication has 22 references indexed in Scilit:
- Positron Emission Tomography/Computerized Tomography (PET/CT) Scanning for Preoperative Staging of Patients With Oral/Head and Neck CancerJournal of Oral and Maxillofacial Surgery, 2007
- High-density materials do not always induce artifacts on PET/CT: What is responsible for the difference?Nuclear Medicine Communications, 2007
- Oral contrast medium in PET/CT: should you or shouldn’t you?European Journal of Nuclear Medicine and Molecular Imaging, 2005
- PET/CT with intravenous contrast can be used for PET attenuation correction in cancer patientsEuropean Journal of Nuclear Medicine and Molecular Imaging, 2005
- A New Algorithm for Metal Artifact Reduction in Computed TomographyInvestigative Radiology, 2003
- Do hardware artefacts influence the performance of head and neck PET scans in patients with oral cavity squamous cell cancer?Dentomaxillofacial Radiology, 2003
- Exact and approximate rebinning algorithms for 3-D PET dataIEEE Transactions on Medical Imaging, 1997
- Total Hip Prosthesis Metal-Artifact Suppression Using Iterative Deblurring ReconstructionJournal of Computer Assisted Tomography, 1997
- Iterative deblurring for CT metal artifact reductionIEEE Transactions on Medical Imaging, 1996
- Accelerated image reconstruction using ordered subsets of projection dataIEEE Transactions on Medical Imaging, 1994