Measurement of Total Energy of Pulsed Electron Beam From a Plasma Focus Device Using Dosimetry of Bremsstrahlung X-Ray
- 9 April 2019
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 47 (5) , 2675-2679
Abstract
In this paper, the total energy of pulsed electron beam from a plasma focus device was studied by measurement of the Bremsstrahlung X-ray dose. The Bremsstrahlung X-ray dose caused by collision of electrons to a copper foil was measured by GR-200A TLD dosimeters. Using the Monte Carlo code, the relationship between the absorbed dose and energy of the colliding electron was determined in the experimental conditions. This relationship is approximately linear and is independent of the electron energy within the energy range of 0–300 keV. The measurements were performed at different charging voltages and different pressures of argon and air as working gases. The mean value of the X-ray dose was higher at experiments with air gas. The maximum X-ray dose of 3.3 mGy, which corresponds to total energy of 48 mJ for electron beam, was measured at 23 kV and 0.9 mbar of air. The total energy of the electron beam at different shots of the same experimental conditions showed large fluctuations around the mean value. This makes it hopelessly difficult to predict the energy of the electron beam in one shot of the plasma focus device. On the other hand, a direct relationship between the energy of the electron pulse and depth of spike on the current signal was observed. The predictability of the energy was significantly improved by increasing the number of shots. The relative standard deviation of the measured energies from the mean value was decreased from 74% for a single shot to 8% for 15 shots, and the mean value of X-ray dose in one shot was significantly increased over the large number of shots.Keywords
This publication has 15 references indexed in Scilit:
- Plasma focus based flash hard X-ray source in the 100 keV region with reproducible spectrumPhysics Letters A, 2010
- Study on electron beam emission from a low energy plasma focus devicePhysics Letters A, 2007
- Spectral study of the electron beam emitted from a 3 kJ plasma focusPlasma Sources Science and Technology, 2005
- Optimization of the high pressure operation regime for enhanced neutron yield in a plasma focus devicePlasma Sources Science and Technology, 2004
- Deposition of titanium nitride thin films on stainless steel—AISI 304 substrates using a plasma focus deviceSurface and Coatings Technology, 2003
- Room temperature deposition of titanium carbide thin films using dense plasma focus deviceSurface and Coatings Technology, 2001
- Electron lithography using a compact plasma focusPlasma Sources Science and Technology, 1997
- Crystallization of an amorphous lead zirconate titanate thin film with a dense-plasma-focus devicePhysical Review B, 1993
- A Method for Measuring Electron Energy Distribution in a Plasma FocusJapanese Journal of Applied Physics, 1990
- Particle beams generated by a 6–12.5 kJ dense plasma focusNuclear Fusion, 1982