Babak Shirani
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Babak Shirani has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Fereydoon Abbassi Davani
Department of Radiation Application, Shahid Beheshti University, Tehran, Iran
4 shared publications Seyed Milad Miremad
Department of Nuclear Engineering, University of Isfahan, Isfahan, Iran
3 shared publicationsKh. Rezaee Ebrahim Saraee
University of Isfahan
2 shared publicationsMahdi Seifi Moradi
Department of Nuclear Engineering, Faculty of Physics, University of Isfahan, Isfahan, Iran
2 shared publications- Mohammad Reza Abdi
Department of Physics, Faculty of Science, University of Isfahan, Isfahan, Iran
2 shared publications V. Ghanei
University of Isfahan
2 shared publications
Latest Publications
- 26 July 2023
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 212
Effects of the Oxygen depletion in FLASH irradiation investigated through Geant4-DNA toolkit
- 26 July 2023
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 212
Effects of the Oxygen depletion in FLASH irradiation investigated through Geant4-DNA toolkit
- 13 January 2023
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 193, 110663
Studies on irradiated photovoltaic cells by proton beam in a plasma focus device
- 13 January 2023
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 193, 110663
Studies on irradiated photovoltaic cells by proton beam in a plasma focus device
- 22 September 2020
- Published by Taylor & Francis in International Journal of Radiation Biology
- Vol. 96 (11) , 1452-1465
Dosimetry study on Auger electron-emitting nuclear medicine radioisotopes in micrometer and nanometer scales using Geant4-DNA simulation
Purpose: Dosimetry of Auger electron-emitting nuclear medicine radioisotopes on cellular and DNA scales is essential in order to assess the biological effects and damage of these radioisotopes to the DNA molecule. This study examined the effects of widely-used radioisotopes in nuclear medicine and also two therapeutic radioisotopes in the scale of micrometer and nanometer. Methods: In this paper, on cell scale (micrometer scale), the S-values for widely-used Auger electron-emitting diagnostic radioisotopes 123I, 125I, 99mTc, 67Ga, 201Tl and 111In and two therapeutic radioisotopes of 131I and 211At in three different geometrical cell models (spherical, elliptical and cubic) were calculated using Geant4-DNA and the results were compared with the results of other simulation codes as well as the MIRD technique. On DNA scale (nanometer scale), the average number of DNA strand breaks (SSB and DSB) resulting from the direct and indirect effects was calculated for the specified radioisotope. Results: The results showed that in the cell scale, S-values of the diagnostic radioisotopes were mostly greater than the S-values of the therapeutic radioisotope 131I, but they were less those of 211At. On DNA scale, two different geometric models of DNA molecule were simulated and the results of these two models were compared with each other, as well as with the literature. The results showed that the geometric shape of sugar-phosphate groups has a significant effect on the break rates of DNA molecules. Conclusions: Among the widely-used diagnostic radioisotopes, 201Tl and 125I had the greatest effect on the rate of SSBs and DSBs, respectively, while the 131I therapeutic radioisotope almost had no effect and therapeutic radioisotope of 211At had a moderate effect on the number of breaks.
- 22 September 2020
- Published by Taylor & Francis in International Journal of Radiation Biology
- Vol. 96 (11) , 1452-1465
Dosimetry study on Auger electron-emitting nuclear medicine radioisotopes in micrometer and nanometer scales using Geant4-DNA simulation
Purpose: Dosimetry of Auger electron-emitting nuclear medicine radioisotopes on cellular and DNA scales is essential in order to assess the biological effects and damage of these radioisotopes to the DNA molecule. This study examined the effects of widely-used radioisotopes in nuclear medicine and also two therapeutic radioisotopes in the scale of micrometer and nanometer. Methods: In this paper, on cell scale (micrometer scale), the S-values for widely-used Auger electron-emitting diagnostic radioisotopes 123I, 125I, 99mTc, 67Ga, 201Tl and 111In and two therapeutic radioisotopes of 131I and 211At in three different geometrical cell models (spherical, elliptical and cubic) were calculated using Geant4-DNA and the results were compared with the results of other simulation codes as well as the MIRD technique. On DNA scale (nanometer scale), the average number of DNA strand breaks (SSB and DSB) resulting from the direct and indirect effects was calculated for the specified radioisotope. Results: The results showed that in the cell scale, S-values of the diagnostic radioisotopes were mostly greater than the S-values of the therapeutic radioisotope 131I, but they were less those of 211At. On DNA scale, two different geometric models of DNA molecule were simulated and the results of these two models were compared with each other, as well as with the literature. The results showed that the geometric shape of sugar-phosphate groups has a significant effect on the break rates of DNA molecules. Conclusions: Among the widely-used diagnostic radioisotopes, 201Tl and 125I had the greatest effect on the rate of SSBs and DSBs, respectively, while the 131I therapeutic radioisotope almost had no effect and therapeutic radioisotope of 211At had a moderate effect on the number of breaks.
- Open Access
- 1 January 2020
- Published by Medknow in Journal of Medical Physics
- Vol. 45 (4) , 240-248
Assessment of single- and double-strand breaks in DNA induced by auger electrons of radioisotopes used in diagnostic and therapeutic applications
Introduction: Most of the radionuclides that are used for diagnostic purposes emit Auger electrons and can thus cause damage to the DNA molecule on a nanometer scale. Therefore, the nanodosimetric calculation of these radioisotopes is necessary to achieve better understanding on their effects. Aim: The aim of this study was to calculate the mean number of DNA strand breaks (single-strand breaks and double-strand breaks) caused by direct and indirect effects for six widely used Auger electron-emitting diagnostic radioisotopes, including 123I, 125I, 99mTc, 67Ga, 201Tl, 111In and two therapeutic radioisotopes of 131I(beta + Auger + CK emitter) and 211At(alpha + Auger + CK emitter). Materials and Methods: Geant4-DNA simulation tool was used to evaluate the effects of Auger electrons, beta and alpha particles of these radioisotopes on DNA molecules. Two different DNA molecule geometric models were simulated and the results of these two models were compared with each other as well as with the results of previous studies. Results and Conclusion: The results showed that the geometric shape of the sugar-phosphate groups may have a significant effect on the number of single-strand breaks (SSBs) and double-strand breaks (DSBs) of the DNA molecule. Among the most widely used diagnostic radioisotopes, 201Tl and 125I, had the greatest impact on the number of SSBs and DSBs, respectively, while therapeutic radioisotope of 131I almost had no effect, therapeutic radioisotope of 211At had the moderate effect on the number of breaks in the DNA chain.
- 1 January 2020
- Published by Medknow in Journal of Medical Physics
- Vol. 45 (4) , 240-248
Open AccessAssessment of single- and double-strand breaks in DNA induced by auger electrons of radioisotopes used in diagnostic and therapeutic applications
Introduction: Most of the radionuclides that are used for diagnostic purposes emit Auger electrons and can thus cause damage to the DNA molecule on a nanometer scale. Therefore, the nanodosimetric calculation of these radioisotopes is necessary to achieve better understanding on their effects. Aim: The aim of this study was to calculate the mean number of DNA strand breaks (single-strand breaks and double-strand breaks) caused by direct and indirect effects for six widely used Auger electron-emitting diagnostic radioisotopes, including 123I, 125I, 99mTc, 67Ga, 201Tl, 111In and two therapeutic radioisotopes of 131I(beta + Auger + CK emitter) and 211At(alpha + Auger + CK emitter). Materials and Methods: Geant4-DNA simulation tool was used to evaluate the effects of Auger electrons, beta and alpha particles of these radioisotopes on DNA molecules. Two different DNA molecule geometric models were simulated and the results of these two models were compared with each other as well as with the results of previous studies. Results and Conclusion: The results showed that the geometric shape of the sugar-phosphate groups may have a significant effect on the number of single-strand breaks (SSBs) and double-strand breaks (DSBs) of the DNA molecule. Among the most widely used diagnostic radioisotopes, 201Tl and 125I, had the greatest impact on the number of SSBs and DSBs, respectively, while therapeutic radioisotope of 131I almost had no effect, therapeutic radioisotope of 211At had the moderate effect on the number of breaks in the DNA chain.
- 1 December 2019
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 154, 108875
Damage study of irradiated tungsten and copper using proton and argon ions of a plasma focus device
- 1 December 2019
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 154, 108875
Damage study of irradiated tungsten and copper using proton and argon ions of a plasma focus device
- 9 April 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 47 (5) , 2675-2679
Measurement of Total Energy of Pulsed Electron Beam From a Plasma Focus Device Using Dosimetry of Bremsstrahlung X-Ray
In this paper, the total energy of pulsed electron beam from a plasma focus device was studied by measurement of the Bremsstrahlung X-ray dose. The Bremsstrahlung X-ray dose caused by collision of electrons to a copper foil was measured by GR-200A TLD dosimeters. Using the Monte Carlo code, the relationship between the absorbed dose and energy of the colliding electron was determined in the experimental conditions. This relationship is approximately linear and is independent of the electron energy within the energy range of 0–300 keV. The measurements were performed at different charging voltages and different pressures of argon and air as working gases. The mean value of the X-ray dose was higher at experiments with air gas. The maximum X-ray dose of 3.3 mGy, which corresponds to total energy of 48 mJ for electron beam, was measured at 23 kV and 0.9 mbar of air. The total energy of the electron beam at different shots of the same experimental conditions showed large fluctuations around the mean value. This makes it hopelessly difficult to predict the energy of the electron beam in one shot of the plasma focus device. On the other hand, a direct relationship between the energy of the electron pulse and depth of spike on the current signal was observed. The predictability of the energy was significantly improved by increasing the number of shots. The relative standard deviation of the measured energies from the mean value was decreased from 74% for a single shot to 8% for 15 shots, and the mean value of X-ray dose in one shot was significantly increased over the large number of shots.
- 9 April 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 47 (5) , 2675-2679
Measurement of Total Energy of Pulsed Electron Beam From a Plasma Focus Device Using Dosimetry of Bremsstrahlung X-Ray
In this paper, the total energy of pulsed electron beam from a plasma focus device was studied by measurement of the Bremsstrahlung X-ray dose. The Bremsstrahlung X-ray dose caused by collision of electrons to a copper foil was measured by GR-200A TLD dosimeters. Using the Monte Carlo code, the relationship between the absorbed dose and energy of the colliding electron was determined in the experimental conditions. This relationship is approximately linear and is independent of the electron energy within the energy range of 0–300 keV. The measurements were performed at different charging voltages and different pressures of argon and air as working gases. The mean value of the X-ray dose was higher at experiments with air gas. The maximum X-ray dose of 3.3 mGy, which corresponds to total energy of 48 mJ for electron beam, was measured at 23 kV and 0.9 mbar of air. The total energy of the electron beam at different shots of the same experimental conditions showed large fluctuations around the mean value. This makes it hopelessly difficult to predict the energy of the electron beam in one shot of the plasma focus device. On the other hand, a direct relationship between the energy of the electron pulse and depth of spike on the current signal was observed. The predictability of the energy was significantly improved by increasing the number of shots. The relative standard deviation of the measured energies from the mean value was decreased from 74% for a single shot to 8% for 15 shots, and the mean value of X-ray dose in one shot was significantly increased over the large number of shots.
- 24 August 2018
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 141, 73-79
Micro-dosimetry calculation of Auger-electron-emitting radionuclides mostly used in nuclear medicine using GEANT4-DNA
- 24 August 2018
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 141, 73-79
Micro-dosimetry calculation of Auger-electron-emitting radionuclides mostly used in nuclear medicine using GEANT4-DNA
- 1 April 2018
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 145, 58-63
Effect of inserted metal at anode tip on formation of pulsed X-ray emitting zone of plasma focus device
- 1 April 2018
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 145, 58-63
Effect of inserted metal at anode tip on formation of pulsed X-ray emitting zone of plasma focus device
- 1 July 2017
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 125, 169-175
Measurement of the effective energy of pulsed X-rays emitted from a Mather-type plasma focus device
- 1 July 2017
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 125, 169-175
Measurement of the effective energy of pulsed X-rays emitted from a Mather-type plasma focus device