Kinetic inductance detectors for the OLIMPO experiment: design and pre-flight characterization
Authors:
- A. PaiellaAPA. Paiella
- A. CoppolecchiaACA. Coppolecchia
- L. LamagnaLLL. Lamagna
- P.A.R. AdePAP.A.R. Ade
- E.S. BattistelliE.S. Battistelli
- M. G. CastellanoMCM. G. Castellano
- I. ColantoniICI. Colantoni
- F. ColumbroFCF. Columbro
- G. D'AlessandroGDG. D'Alessandro
- P. de BernardisPBP. de Bernardis
- S. GordonSGS. Gordon
- S. MasiSMS. Masi
- 1 January 2019
- journal article
- research article
- Published by IOP Publishing in Journal of Cosmology and Astroparticle Physics
- Vol. 2019 (01) , 039
Abstract
We designed, fabricated, and characterized four arrays of horn-coupled, lumped element kinetic inductance detectors (LEKIDs), optimized to work in the spectral bands of the balloon-borne OLIMPO experiment. OLIMPO is a 2.6 m aperture telescope, aimed at spectroscopic measurements of the Sunyaev-Zel'dovich (SZ) effect. OLIMPO will also validate the LEKID technology in a representative space environment. The corrected focal plane is filled with diffraction limited horn-coupled KID arrays, with 19, 37, 23, 41 active pixels respectively at 150, 250, 350, and 460 GHz. Here we report on the full electrical and optical characterization performed on these detector arrays before the flight. In a dark laboratory cryostat, we measured the resonator electrical parameters, such as the quality factors and the electrical responsivities, at a base temperature of 300 mK. The measured average resonator Qs are 1.7× 104, 7.0× 103, 1.0× 104, and 1.0× 104 for the 150, 250, 350, and 460 GHz arrays, respectively. The average electrical phase responsivities on resonance are 1.4 rad/pW, 1.5 rad/pW, 2.1 rad/pW, and 2.1 rad/pW; the electrical noise equivalent powers are 45 aW/√Hz, 160 aW/√Hz, 80 aW/√Hz, and 140 aW/√Hz, at 12 Hz. In the OLIMPO cryostat, we measured the optical properties, such as the noise equivalent temperatures (NET) and the spectral responses. The measured NETRJs are 200 μ K.√s, 240 μK √s, 240 μK √s, and 340 μK √s, at 12 Hz; under 78, 88, 92, and 90 mK Rayleigh-Jeans blackbody load changes respectively for the 150, 250, 350, and 460 GHz arrays. The spectral responses were characterized with the OLIMPO differential Fourier transform spectrometer (DFTS) up to THz frequencies, with a resolution of 1.8 GHz.Keywords
All Related Versions
This publication has 31 references indexed in Scilit:
- A tiltable single-shot miniature dilution refrigerator for astrophysical applicationsCryogenics, 2013
- Low-resolution spectroscopy of the Sunyaev-Zel’dovich effect and estimates of cluster parametersAstronomy & Astrophysics, 2012
- A DUAL-BAND MILLIMETER-WAVE KINETIC INDUCTANCE CAMERA FOR THE IRAM 30 m TELESCOPEThe Astrophysical Journal Supplement Series, 2011
- THE ATACAMA COSMOLOGY TELESCOPE (ACT): BEAM PROFILES AND FIRST SZ CLUSTER MAPSThe Astrophysical Journal Supplement Series, 2010
- GALAXY CLUSTERS DISCOVERED WITH A SUNYAEV-ZEL'DOVICH EFFECT SURVEYThe Astrophysical Journal, 2009
- Lumped Element Kinetic Inductance DetectorsJournal of Low Temperature Physics, 2008
- A broadband superconducting detector suitable for use in large arraysNature, 2003
- Quasiparticle-phonon downconversion in nonequilibrium superconductorsPhysical Review B, 2000
- The Cosmic Microwave Background Spectrum from the FullCOBEFIRAS Data SetThe Astrophysical Journal, 1996
- Theory of SuperconductivityPhysical Review B, 1957