Effective Length Spectra for Cross Bracings
Author:
- 1 December 1989
- journal article
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 115 (12) , 3112-3122
Abstract
General effective length criteria for cross‐bracing systems are formulated. The criteria entail closed‐form analytic relationships for evaluating compression brace critical load and effective length factor K with due consideration of the relative stiffness and end conditions of the tensile diagonal. Effective length spectra curves are generated to elucidate the criteria and to facilitate design application. Results indicate that the effective length is very sensitive to the relative stiffness of the two interconnected diagonals and, depending on brace end conditions, the effective length factor values range from 0.35 to 1.0. Refereed experimental data available in the range agree well with the proposed solution. Application of the criteria will lead to an optimum design and enhance overall structural stability.Keywords
This publication has 6 references indexed in Scilit:
- Closure to “ Stiffness Requirements for Cross Bracing ” by Sritawat Kitipornchai and David L. Finch (December, 1986, Vol. 112, No. 12)Journal of Structural Engineering, 1988
- Discussion of “ Stiffness Requirements for Cross Bracing ” by Sritawat Kitipornchai and David L. Finch (December, 1986, Vol. 112, No. 12)Journal of Structural Engineering, 1988
- Stability Criteria for X‐Bracing SystemsJournal of Engineering Mechanics, 1988
- Stiffness Requirements for Cross BracingJournal of Structural Engineering, 1986
- Cross-Bracing DesignJournal of the Structural Division, 1979
- The Use of X-Bracing in Fixed Offshore Platforms1972