Noninvasive ventilation through a helmet in postextubation hypoxemic patients: physiologic comparison between neurally adjusted ventilatory assist and pressure support ventilation
- 18 October 2011
- journal article
- research article
- Published by Springer Nature in Intensive Care Medicine
- Vol. 37 (12) , 1943-1950
Abstract
Neurally adjusted ventilatory assist (NAVA) has been shown to improve patient–ventilator interaction and reduce asynchronies in intubated patients, as opposed to pressure support ventilation (PSV). This is a short-term head-to-head physiologic comparison between PSV and NAVA in delivering noninvasive ventilation through a helmet (h-NIV), in patients with postextubation hypoxemic acute respiratory failure. Ten patients underwent three 20-min trials of h-NIV in PSV, NAVA, and PSV again. Arterial blood gases (ABGs) were assessed at the end of each trial. Diaphragm electrical activity (EAdi) and airway pressure (P aw) were recorded to derive neural and mechanical respiratory rate and timing, inspiratory (delayTR-insp) and expiratory trigger delays (delayTR-exp), time of synchrony between diaphragm contraction and ventilator assistance (timesynch), and the asynchrony index (AI). ABGs, peak EAdi, peak P aw, respiratory rate, either neural or mechanical, neural timing, and delayTR-exp were not different between trials. Compared with PSV, with NAVA the mechanical expiratory time was significantly shorter, while the inspiratory time and duty cycle were greater. Timesynch was 0.79 ± 0.35 s in NAVA versus 0.60 ± 0.30 s and 0.55 ± 0.29 s during the PSV trials (p < 0.01 for both). AI exceeded 10% during both PSV trials, while not in NAVA (p < 0.001). Compared with PSV, NAVA improves patient–ventilator interaction and synchrony, with no difference in gas exchange, respiratory rate, and neural drive and timing.Keywords
This publication has 29 references indexed in Scilit:
- Neurally adjusted ventilatory assist in patients recovering spontaneous breathing after acute respiratory distress syndrome: Physiological evaluation*Critical Care Medicine, 2010
- Neurally Adjusted Ventilatory Assist Increases Respiratory Variability and Complexity in Acute Respiratory FailureAnesthesiology, 2010
- Patient-ventilator interaction during pressure support ventilation and neurally adjusted ventilatory assist*Critical Care Medicine, 2010
- Helmet with specific settings versus facemask for noninvasive ventilation*Critical Care Medicine, 2009
- Titration and Implementation of Neurally Adjusted Ventilatory Assist in Critically Ill PatientsChest, 2009
- Subject–ventilator synchrony during neural versus pneumatically triggered non-invasive helmet ventilationIntensive Care Medicine, 2008
- Asynchrony and cyclic variability in pressure support noninvasive ventilationComputers in Biology and Medicine, 2007
- Noninvasive Positive Pressure Ventilation Using a Helmet in Patients with Acute Exacerbation of Chronic Obstructive Pulmonary DiseaseAnesthesiology, 2004
- Randomized controlled trial of discontinuation of nasal‐CPAP in stable preterm infants breathing room airActa Paediatrica, 1998
- Patient-ventilator interaction and inspiratory effort during pressure support ventilation in patients with different pathologiesEuropean Respiratory Journal, 1997