A 3D printed chemiluminescence detector for the FIA determination of free available chlorine in concentrated chlorine dioxide solutions
- 3 October 2025
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 150 (21) , 4789-4797
Abstract
Chlorination is the most widely used and cost-effective method for disinfecting drinking water worldwide. Unfortunately, this approach leads to the formation of disinfection by-products (DBPs), which have been shown to increase the potential for cancer and other health issues. To minimize DBPs, many water treatment plants have turned to alternative disinfectants such as chlorine dioxide (ClO2). However, there have been reports of DBP formation when using ClO2 due to free available chlorine (FAC) contamination. A suitable method is needed to determine the FAC content in concentrated ClO2 solutions. This research addresses this need by focusing on the development of a simple flow-injection analyzer with a 3D printed chemiluminescence detector (FIA-3DCL). A gas-diffusion membrane module was used to isolate FAC from a quenched ClO2 solution, then react it with lophine reagent to produce chemiluminescent light. The analytical performance of the FIA-3DCL system was evaluated by performing calibration, method detection limit, accuracy, and precision studies. Three calibration data regression techniques were compared, with the logarithmic fit having the best results. Following these studies, commercially available ClO2 solutions were analyzed for FAC and used in spiking studies. Overall, the system provides a straightforward and automated method for determining μg L−1 levels of FAC in solutions with g L−1 levels of ClO2.Keywords
Funding Information
- National Science Foundation (SBIR Phase II NSF Grant #1556127)
This publication has 50 references indexed in Scilit:
- The Chemiexcitation of the Chemiluminescence of Lophine Peroxide Anions via a Partially Cyclic Transition StateEuropean Journal of Organic Chemistry, 2013
- Evaluation of lophine derivatives as L‐012 (luminol analog)‐dependent chemiluminescence enhancers for measuring horseradish peroxidase and H2O2Luminescence, 2013
- Applications of the luminol chemiluminescent reaction in analytical chemistryAnalytical and Bioanalytical Chemistry, 2006
- Lophine derivatives as versatile analytical toolsBiomedical Chromatography, 2003
- Analytical applications of flow injection with chemiluminescence detection—a reviewLuminescence, 2001
- Flow-Injection Analysis of Cobalt(II) Utilizing Enhanced Lophine Chemiluminescence with Hydroxylammonium ChlorideBiomedical Chromatography, 1997
- Specificity of the DPD and Amperometric Titration Methods for Free Available Chlorine: A ReviewJournal AWWA, 1989
- Methods of Measuring Disinfectant ResidualsJournal AWWA, 1988
- A Review of Chlorine Dioxide in Drinking Water TreatmentJournal AWWA, 1986
- Determination of Chlorine Dioxide, Chlorine, Chlorite, and Chlorate in WaterJournal AWWA, 1984