PSPaul S. Simone

Paul S. Simone

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Paul S. Simone has a total of 21 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Mycoplasma gallisepticum uses itaconate-associated mitochondrial inhibition to suppress host immunometabolism

    by Soren Z Coulson, Reihane Eric, Chidambaram Ramanathan, Katie M Talbott, Francis E Tillman, Anna Perez-Umphrey, Truc Chi Thi Pham, Paul S Simone, Brandt D Pence, James S Adelman, et al.

    Many pathogens actively suppress early host immune responses to enhance their fitness. Mitochondria function as key regulators of immune activation, yet whether pathogens suppress host immunity by manipulating mitochondrial metabolism in vivo remains largely unknown. During an innate immune response, the metabolite itaconate increases in abundance and acts as an immunomodulator, due to its inhibition of succinate dehydrogenase (SDH), a key mitochondrial regulator of cellular immunity. We hypothesized that Mycoplasma gallisepticum (MG), a recently emerged pathogen of wild songbirds, most notably house finches ( Haemorhous mexicanus ), suppresses early host immune responses by limiting SDH-dependent immune activation via itaconate. We tested these hypotheses using experimental 3-day infection of finches with heat-killed MG, live MG or pharmacological elevation of the SDH inhibitor itaconate. Following inoculation, we quantified intracellular itaconate and mitochondrial respiratory function in peripheral blood mononuclear cells (PBMCs) and pro-inflammatory cytokine gene expression in erythrocytes, in addition to infected tissues (trachea and conjunctiva). Heat-killed MG increased SDH-dependent mitochondrial respiration in PBMCs and cytokine gene expression in erythrocytes, but live MG did not show these increases, but revealed increased itaconate accumulation in PBMCs. Dimethyl itaconate administration reproduced the suppressed metabolic and immune phenotype in blood cells observed with live MG, suggesting an itaconate-associated mechanism. In contrast, live MG increased mitochondrial respiration and gene expression levels of cytokines in eyelid conjunctiva, whereas other treatments did not. These findings indicate that MG suppresses host metabolic and cytokine signaling in systemically circulating immune cells through a mechanism consistent with itaconate-mediated inhibition of SDH-dependent mitochondrial respiration, while still inducing an inflammatory response at the site of infection. Our data suggest that MG, like other pathogens, can commandeer host immunometabolic pathways during infection to their benefit and that mitochondria are a key site of competition between host and pathogen.

  • A 3D printed chemiluminescence detector for the FIA determination of free available chlorine in concentrated chlorine dioxide solutions

    by Robyn A. Snow, Paul S. Simone, Gary L. Emmert, Michael A. Brown

    Chlorination is the most widely used and cost-effective method for disinfecting drinking water worldwide. Unfortunately, this approach leads to the formation of disinfection by-products (DBPs), which have been shown to increase the potential for cancer and other health issues. To minimize DBPs, many water treatment plants have turned to alternative disinfectants such as chlorine dioxide (ClO2). However, there have been reports of DBP formation when using ClO2 due to free available chlorine (FAC) contamination. A suitable method is needed to determine the FAC content in concentrated ClO2 solutions. This research addresses this need by focusing on the development of a simple flow-injection analyzer with a 3D printed chemiluminescence detector (FIA-3DCL). A gas-diffusion membrane module was used to isolate FAC from a quenched ClO2 solution, then react it with lophine reagent to produce chemiluminescent light. The analytical performance of the FIA-3DCL system was evaluated by performing calibration, method detection limit, accuracy, and precision studies. Three calibration data regression techniques were compared, with the logarithmic fit having the best results. Following these studies, commercially available ClO2 solutions were analyzed for FAC and used in spiking studies. Overall, the system provides a straightforward and automated method for determining μg L−1 levels of FAC in solutions with g L−1 levels of ClO2.

  • A low-cost, high-sensitivity 3D printed fluorescence detector

    by Robyn A. Snow, Paul S. Simone, Gary L. Emmert, Michael A. Brown

    A low-cost, high-sensitivity 3D printed fluorescence detector with comparable performance to a commercial detector and method adaptability.


  • Automated system for performing pH-based titrations

    by Naga P. D. Boppana, Robyn A. Snow, Paul S. Simone, Gary L. Emmert, Michael A. Brown

    Liquid delivery and endpoint determination during titrations may be problematic if an analyst does not have adequate training or formal education. This can lead to issues with method accuracy and precision. This work is focused on the development of a simple, low-cost, automated system capable of performing potentiometric titrations with a push of a button. A single-board computer (Raspberry Pi), a stepper motor-based syringe pump, and a commercially available pH sensor circuit board were the primary components used to construct the auto-titrator system. Open-source Python programming language was used to control and coordinate components and provide a simple-to-use graphical user interface. A standard alkalinity method for drinking and raw water was evaluated and yielded an accuracy (recovery) between 92% and 104% for concentrations above 10 mg L−1. The precision of the method was less than 5% regardless of concentration. The developed titrator was tested at Lebanon, TN, and Woodruff, SC water treatment plants. The system was also certified by LabtronX to perform alkalinity measurements in Lebanon, TN, and served the plant operators for the past two years.


  • Low-cost automated pipetting system using a single board computer and 3D-printing

    by Naga P. D. Boppana, Robyn A. Snow, Paul S. Simone, Gary L. Emmert, Michael A. Brown

    A low-cost, automated pipetting system (auto pipet) was developed to deliver microliter volumes of aqueous solutions. This system was constructed using a single board computer, 3 D-printed parts, stepper motors, and other commercially available components. The performance of the auto pipet was found to be comparable or better than manual pipetting and a commercially available liquid handling system. Inter-day, intra-day, inter-instrumental, and intra-instrumental validation studies were performed to evaluate the accuracy and precision of liquid delivery using the auto pipet. Accuracy was determined to be from 98 to 102% with the precision, represented as the relative standard deviation, to be less than 3%. The auto pipet was further evaluated by the preparation of calibration and check standards for the determination of method detection limit, accuracy, and precision for trihalomethanes using a commercially available monitoring system. The auto pipet was also used as a digital buret to perform water hardness and water alkalinity titrations with promising results. Graphical Abstract


  • Hydrogen Production Coupled to Hydrocarbon Oxygenation from Photocatalytic Water Splitting

    by Wangkheimayum Marjit Singh, Derek Pegram, Haifeng Duan, Diganta Kalita, Paul Simone, Gary L. Emmert, Xuan Zhao