Surface Microbial Contamination and Air Quality before and after Regular Cleaning Procedures
Open Access
- 10 February 2023
- journal article
- research article
- Published by MDPI AG in Atmosphere
- Vol. 14 (2) , 352
Abstract
Studies on indoor air quality (IAQ) have linked exposure to microorganisms in indoor air to a variety of illnesses. The association between indoor air quality, surface contamination, and IAQ under heterogeneous cleaning procedures are all crucial factors that were investigated in this study. The ATP bioluminescence test demonstrated a significant correlation (r = 0.89; p 0.05) with bacterial count obtained from swab specimens and a moderate correlation (r = 0.57; p 0.001) with viable settling bacterial count. For the entire sample (pre- and post-cleaning), the ATP values were heterogeneous, averaging 230 RLU/100 cm2, 140 RLU/100 cm2, 120 RLU/100 cm2, 135 RLU/100 cm2, 99 RLU/100 cm2, and 80 RLU/100 cm2, in offices, classrooms, toilet doorknobs, reception desks, main lobbies, and exit doorknobs, respectively. An insignificant association between indoor and outdoor PM2.5 (r = 0.21; p 0.05), an I/O ratio of PM2.5 with an average value of 1.2, and an I/O ratio of CO2 exceeding 1 suggest a minor impact of outdoor air. After cleaning, the bacterial and fungal counts on indoor surfaces showed significant reduction, suggesting that the cleaning procedures were effective. The concentrations of VOC but not HCHO in indoor air were significantly affected by cleaning, but not by temperature or relative humidity (RH). We propose ATP bioluminescence as a surrogate for detecting bacterial contamination rather than fungal contamination, which requires additional validation. We suggest that the results of active microbial sampling (in CFU/m3) and settling plates (in CFU/m2/h) be interpreted independently to avoid confusion.Keywords
Funding Information
- Deanship of Scientific Research at Saudi Electronic University (8020-HS-2020-1-2020-I)
This publication has 78 references indexed in Scilit:
- Microbiological hazard analysis of ready-to-eat meats processed at a food plant in Trinidad, West IndiesInfection Ecology & Epidemiology, 2013
- Air sampling procedures to evaluate microbial contamination: a comparison between active and passive methods in operating theatresBMC Public Health, 2012
- Effects of Particulate Air Pollution on Cardiovascular Health: A Population Health Risk AssessmentPLOS ONE, 2012
- Airborne urban particles (Milan winter-PM2.5) cause mitotic arrest and cell death: Effects on DNA, mitochondria, AhR binding and spindle organizationMutation Research - Fundamental and Molecular Mechanisms of Mutagenesis, 2011
- Application of chlorine dioxide for disinfection of student health centersEnvironmental Monitoring and Assessment, 2011
- Indoor and outdoor urban atmospheric CO2: Stable carbon isotope constraints on mixing and mass balanceApplied Geochemistry, 2010
- VOC Concentrations in an Indoor Workplace Environment of a University BuildingIndoor and Built Environment, 2008
- Effect of chemical composition on the induction of DNA damage by urban airborne particulate matterEnvironmental and Molecular Mutagenesis, 2005
- Cardiovascular Mortality and Long-Term Exposure to Particulate Air PollutionCirculation, 2004
- Correlation between surface and air counts of particles carrying aerobic bacteria in operating rooms with turbulent ventilation: an experimental studyJournal of Hospital Infection, 1999