MMMohammed O. A. Mohammed

Mohammed O. A. Mohammed

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Mohammed O. A. Mohammed has a total of 27 co-authors. Here are the top co-authors by number of shared publications:

  • Li-Yan Liu

    International Joint Research Center for Persistent Toxic Substances (IJRC-PTS), State Key Laboratory of Urban Water Resource and Environment, School of Municipal and Environmental Engineering, Harbin Institute of Technology, Harbin 150090, China

    3 shared publications
  • Ahmed A. Elzaki

    Faculty of Public and Environmental Health, Department of Environmental Health & Environmental Studies, Khartoum University, Khartoum, Sudan

    2 shared publications
  • Hong Qi

    2 shared publications
  • Wan-Li Ma

    2 shared publications
  • Abdalmoiz A. M. Solumon

    Univ Khartoum, Fac Publ & Environm Hlth, Khartoum 205, Sudan

    1 shared publication
  • Babiker A. Babiker

    Faculty of Public and Environmental Health, Department of Environmental Health & Environmental Studies, Khartoum University, Khartoum, Sudan

    1 shared publication

Latest Publications

  • Open Access

    Blackboard® LMS for blended learning: Students’ views versus staff views on challenges and improvement

    by Mohammed O. A. Mohammed, Muhanad El Hag, Mohamed A. E. M. Ibrahim, Javed Khan

    The Blended learning system (BELS) has become a popular tool of learning. BELS’s effectiveness is substantially influenced by a number of elements, including teacher and student feedback and system design. This study on evaluating the Blackboard platform (removed for peer review) aims to determine the similarity between students’ and faculty members’ perspectives, identify the least satisfied elements of learning that need improvement, and collect suggestions for future enhancements. Using the SurveyMonkey service, questionnaires were sent directly to the emails of students and faculty members at the four colleges of the university. There were 1170 responses from students and 93 responses from staff members. SAS JMP was used to perform Linear Discriminant Analysis (LDA) to show the relationships between academic staff perceptions and their recommendations from one side and the students’ perceptions and satisfactions distributed by colleges from another side, while SPSS was used to visualize the data. Students and faculty were highly satisfied with blended learning and high expectations for its effectiveness The perceptions of faculty members were similar to those of students; however, they were more satisfied with certain features than students were. The LDA results of staff survey demonstrated that the responses of faculty members vary by college, unlike the LDA for students’ survey that did no show between-college variations. This implies that, students across colleges have similar needs and common attitudes toward BEL. Students were least satisfied with peer interactions; online IT assistance; the development of skills using current students’ activities; and the update frequency and quality of online content. We advocate incorporating student perspectives into plans and considering faculty members’ suggestions particularly for increasing peer-to-peer learning; in-line translation and use of infographics.


  • Open Access

    Multivariate Analysis for Characterization of Air Pollution Sources: Part 1 Prior Data Screening and Underlying Assumptions

    by Mohammed O.A. Mohammed

    There is a real need for comparability and consistency of findings obtained from different multivariate methods, based on different assumptions and sensitivity to data errors. This study aims to investigate essential aspects of data screening prior to analysis, particularly the detection of outliers, communalities, multicollinearity, and Kaiser-Meyer-Olkin (KMO) and Bartlett’s tests, and to examine the influence of changing test parameters such as the number of convergence, number of bootstrap runs, FPEAK value, and minimum value of coefficient of determination (R2) on model results. Positive matrix factorization (PMF) and Unmix were applied to monitoring data collected from a receptor site. Findings of communalities estimate and multicollinearity indicated possible data errors in Ca, Cu, Na, and Mn, which affected the stability of source profiles. PMF detected biomass burning, coal combustion, traffic, industrial emissions, Mn-enriched sources, and secondary aerosols, while the Unmix model identified similar sources with comparable profiles, apart from profiles of vehicle exhaust and industrial emissions showing slight differences. Unmix was highly influenced by outliers, multicollinearity, and, to a lesser extent, change in sample size compared to PMF. We recommend interpreting the results of Bootstrapping, rather than basic runs for both PMF and Unmix. We also recommend data screening prior to further modeling. We suggest checking multicollinearity using more than one statistical measure, particularly VIF (Variance Inflation Factor) values together with tolerance values.


  • Open Access

    Surface Microbial Contamination and Air Quality before and after Regular Cleaning Procedures

    by Mohammed O. A. Mohammed

    Studies on indoor air quality (IAQ) have linked exposure to microorganisms in indoor air to a variety of illnesses. The association between indoor air quality, surface contamination, and IAQ under heterogeneous cleaning procedures are all crucial factors that were investigated in this study. The ATP bioluminescence test demonstrated a significant correlation (r = 0.89; p 0.05) with bacterial count obtained from swab specimens and a moderate correlation (r = 0.57; p 0.001) with viable settling bacterial count. For the entire sample (pre- and post-cleaning), the ATP values were heterogeneous, averaging 230 RLU/100 cm2, 140 RLU/100 cm2, 120 RLU/100 cm2, 135 RLU/100 cm2, 99 RLU/100 cm2, and 80 RLU/100 cm2, in offices, classrooms, toilet doorknobs, reception desks, main lobbies, and exit doorknobs, respectively. An insignificant association between indoor and outdoor PM2.5 (r = 0.21; p 0.05), an I/O ratio of PM2.5 with an average value of 1.2, and an I/O ratio of CO2 exceeding 1 suggest a minor impact of outdoor air. After cleaning, the bacterial and fungal counts on indoor surfaces showed significant reduction, suggesting that the cleaning procedures were effective. The concentrations of VOC but not HCHO in indoor air were significantly affected by cleaning, but not by temperature or relative humidity (RH). We propose ATP bioluminescence as a surrogate for detecting bacterial contamination rather than fungal contamination, which requires additional validation. We suggest that the results of active microbial sampling (in CFU/m3) and settling plates (in CFU/m2/h) be interpreted independently to avoid confusion.


  • Two Models of Household Sand Filters for Small Scale Water Purification

    by Mohammed O. A. Mohammed, Abdalmoiz A. M. Solumon

    Access to sufficient quantities of safe water is not just a public health issue but also a human right. Water pollution causes millions of deaths and illnesses every year. To solve the issue of water pollution at household levels and during emergencies, slow sand filters are suggested as good choices. This study aimed at designing small scale Household Slow Sand Filter (HSSF) with locally available materials. This experimental study was conducted under ambient weather conditions to test efficiency of two proposed filters in removing pollutants from source water. Natural water samples were collected from the Blue Nile, and the White Nile. The two filters were first cleaned up followed by a ripening period of two weeks to allow formation of the Schmutzdecke (the biological layer). Data were subjected to Hierarchical cluster analysis (HCA), ANOVA and Pearson correlation. The current research revealed that, both filters were highly efficient in removing E.coli and total coliform. The average log10 removal of total Coliforms and E Coli for the first filter ranged between 1.9 log and 1.7 log compared to a range of 1.1 log to 1.2 log for the second filter. The association of log10 total coliforms with turbidity and TSS has drastically changed after filtration. Overall, the best performance of filter 1 was reported for removal of bacteria, turbidity, iron (Fe), TSS, K and NO2, and Zn, respectively, versus NO2, Fe and Zn for filter 2, in the same order. The trend of ions removal assumed to be affected by both mineralization and oxidation which further supported by HCA results and it was differ than the pattern of heavy metals removal that was generally moderate not exceeded 65%. All soluble ions after filtration did not exceeded WHO guideline limits. The first proposed filter suggested to be efficient that need to be confirmed by further studies.


  • Spatial variability of outdoor exposure to radiofrequency radiation from mobile phone base stations, in Khartoum, Sudan

    by Mohammed O. A. Mohammed, Ahmed A. Elzaki, Babiker A. Babiker, Omer I. Eid

    The wide-spread exposure to constantly evolving wireless technologies believed to pose a serious health threat. Human beings are persistently exposed to RF radiation from mobile phones and their base stations. The current study aimed at classifying and characterizing the exposure to RF radiation from the mobile phone base stations. Spatial distribution measurements were carried out in Khartoum city during two time periods, first in 2012 (pilot survey) and again during Sept. 2019–Jan. 2020, to cover a total of 282 antennas operating with GSM900, GSM1800, and UMTS2100. The tested antennas belong to three mobile communication companies namely Sudani, Zain, and MTN companies, that randomly coded into company A, company B, and company C for security purposes. Measurements were performed using frequency-selective RF analyzer at fixed distances from the antennas/towers. Data were subjected to advanced repeated measures ANOVA, linear discriminant analysis (LDA), and spatial interpolation with ArcGIS. The averages of GSM900, GSM1800, and UMTS measurements were 0.01933 W/m2, 0.0067 W/m2, and 0.0046 W/m2. The high levels of power densities for each single antenna were recorded at 90 m, 110 m, 130 m, and at 150 m distances, for the majority (70%) of the measured antennas and the peak/highest values reported mainly at 110 m distance. Conversely, the discriminant loadings as part of LDA, suggested that, much of variance among measurements is attributed to measurements at 150 m, 170 m, and 190 m distances, while visual illustration of group centroids implied that, the RF signals of the different companies were measured separately which support accuracy of frequency-selective measurements. The LDA has confirmed the ANOVA results that, the overall difference between the three companies was statistically significant for UMTS, and GSM900 measurements but not significant for GSM1800 measurements. Kriging interpolation using ArcGIS provided a strong evidence of great spatial distribution of exposure across the study area, with market places and typical urban residential quarters showing highest levels of RF. Few extreme values exceeding ICNIRP limits are reported but excluded from the calculations because of an issue of normality of data that is considered a prerequisite for parametric data analysis. Existence of extreme levels of RF indicates a need for further investigation and some antennas of Company B are mounted on towers belongs to Company C, implying multi exposure. Unexpected pattern of RF levels continued to increase up to 190 m distance and possibly beyond 190 m is reported for UMTS measurements of Company C.


  • Open Access

    Distribution patterns and characterization of outdoor fine and coarse particles

    by Mohammed O.A. Mohammed, Wei-Wei Song, Li-Yan Liu, Wan-Li Ma, Yi-Fan Li, Feng-Yan Wang, Mohammed A.E.M. Ibrahim, Mei-Yun Qi, Ahmed A. Elzaki, Na Lv


    • 1 December 2012
      • Vol. 33  (12) , 4220-5

    [Pollution characteristics of polycyclic aromatic hydrocarbons in water of Songhua River basin during the icebound season].

    by Wan-Li Ma, Li-Yan Liu, Hong Qi, Yang Bai, Ji-Min Shen, Zhong-Lin Chen, Yi-Fan Li

    The pollution characteristics of polycyclic aromatic hydrocarbons (PAHs) in surface water samples of the three major sections of the Songhua River Basin (the Nenjiang River, the Second Songhua River and the mainstream of the Songhua River) were studied. A total of 21 surface water samples were collected in icebound season in 2010 along the bank. The total concentrations of 15 species of PAHs ranged from 23.4 ng x L(-1) to 85.1 ng x L(-1), with an average concentration at (50.3 +/- 17) ng x L(-1), which was comparable with those of other rivers in China. PAHs had higher concentration in lower reaches of the river around neighboring cities, which maybe caused by municipal/industrial effluents of the cities along the bank. The sources of PAHs were further identified by principal component analysis (PCA), which indicated that the main source of PAHs was fossil fuel related combustion in Songhua River. The potential ecosystem risk assessment of individual PAHs was characterized by risk quotient (RQ). The results indicated that the ecological risk of high molecular weight PAHs was negligible and low molecular weight PAHs possessed greater ecological risk.

  • Endosulfan in China: Usage, Emissions, and Residues

    by Hongliang Jia, Liyan Liu, Yeqing Sun, Yi-Fan Li

    • 1 November 2009
      • Vol. 30  (11) , 3167-72

    [Gaseous polycyclic aromatic hydrocarbons in Harbin air].

    by Wan-Li Ma, Yi-Fan Li, De-Zhi Sun, Hong Qi, Li-Yan Liu, Zhi Zhang, Chong-Guo Tian, Ji-Min Shen

    Polyurethane foam passive air samplers (PUF PAS) were fixed at eight sampling sites in Harbin Region concurrently to research atmospheric concentration and distribution of polycyclic aromatic hydrocarbons (PAHs) in Spring of 2007 (January to April). Results showed that the PUF PAS mostly absorbed the 3-4 ring PAHs, which accounted for 91.22%-96.37% comparing to total concentration. Total PAHs concentration had obvious area difference from urban to remote areas, such as 356.49 ng/d for urban, 162.65 ng/d for suburban, 278.35 ng/d for rural and 183.99 ng/d for background, with ratios of urban atmospheric concentration to rural concentration more than 2, three times higher than that of remote area. The atmospheric concentration was significantly affected by sources. Sources of PAHs in air of Harbin Region were investigated by diagnostic ratios, which indicated that coal and biofuel combustion were the main sources of PAHs in air of urban and rural area, respectively. The toxic equivalence factor (TEF) was used for health risk assessment, with similar area difference to concentration distribution, which implying bigger potential heath risk for urban and rural people than other areas. Good reproducibility of PUF passive air sampler was confirmed by one pair of passive samplers deployed at an urban site. The results of the study demonstrated the capability of PUF PAS to monitor atmospheric PAHs in a city scale at the same time.