Linear Fiber Laser Configurations for Optical Concentration Sensing in Liquid Solutions
Open Access
Abstract
In this study, different configurations based on linear fiber lasers were proposed and experimentally demonstrated to measure the concentration of liquid solutions. Samples of paracetamol liquid solutions with different concentrations, in the range from 52.61 to 201.33 g/kg, were used as a case-study. The optical gain was provided by a commercial bidirectional Erbium-Doped Fiber Amplifier (EDFA) and the linear cavity was obtained using two commercial Fiber Bragg Gratings (FBGs). The main difference of each configuration was the coupling ratio of the optical coupler used to extract the system signal. The sensing head corresponded to a Single-Mode Fiber (SMF) tip that worked as an intensity sensor. The results reveal that, despite the optical coupler used (50:50, 60:40, 70:30 or 80:20), all the configurations reached the laser condition, however, the concentration sensing was only possible using a laser drive current near to the threshold value. The configurations using a 70:30 and an 80:20 optical coupler allowed paracetamol concentration measurements with a higher sensitivity of () pW/(g/kg) to be performed. In terms of resolution, the highest value obtained was 1.75 g/kg, when it was extracted at 20% of the output power to the linear cavity fiber laser configuration.
Keywords
All Related Versions
Funding Information
- FCT—Fundação para a Ciência e a Tecnologia (UIDB/50014/2020, LA/P/0045/2020, UIDB/00511/2020, UIDP/00511/2020, 2020.05297.BD, PID2019-107270RB-C22, PID2022-137269OB-C21, PDC2021-121172-C21, TED2021-130378B-C22, CAS21/00351)
- national funds through FCT/MCTES (PIDDAC) (UIDB/50014/2020, LA/P/0045/2020, UIDB/00511/2020, UIDP/00511/2020, 2020.05297.BD, PID2019-107270RB-C22, PID2022-137269OB-C21, PDC2021-121172-C21, TED2021-130378B-C22, CAS21/00351)
- FCT (UIDB/50014/2020, LA/P/0045/2020, UIDB/00511/2020, UIDP/00511/2020, 2020.05297.BD, PID2019-107270RB-C22, PID2022-137269OB-C21, PDC2021-121172-C21, TED2021-130378B-C22, CAS21/00351)
- MCIN/AEI/10.13039/501100011033 and FEDER “A way to make Europe” (UIDB/50014/2020, LA/P/0045/2020, UIDB/00511/2020, UIDP/00511/2020, 2020.05297.BD, PID2019-107270RB-C22, PID2022-137269OB-C21, PDC2021-121172-C21, TED2021-130378B-C22, CAS21/00351)
- MCIN/AEI/10.13039/501100011033 and European Union “Next generation EU”/PRTR (UIDB/50014/2020, LA/P/0045/2020, UIDB/00511/2020, UIDP/00511/2020, 2020.05297.BD, PID2019-107270RB-C22, PID2022-137269OB-C21, PDC2021-121172-C21, TED2021-130378B-C22, CAS21/00351)
- Ministerio de Universidades of Spain (UIDB/50014/2020, LA/P/0045/2020, UIDB/00511/2020, UIDP/00511/2020, 2020.05297.BD, PID2019-107270RB-C22, PID2022-137269OB-C21, PDC2021-121172-C21, TED2021-130378B-C22, CAS21/00351)
This publication has 11 references indexed in Scilit:
- Fiber Laser Sensor Configurations for Refractive Index, Temperature and Strain: A ReviewPhotonics, 2023
- The differentiation procedure between amplified spontaneous emission and lasing phenomenaOptics Communications, 2022
- Dual-Polarization Distributed Feedback Fiber Laser Sensor Based on Femtosecond Laser-Inscribed In-Fiber Stressors for Simultaneous Strain and Temperature MeasurementsIEEE Access, 2020
- Temperature sensor and fiber laser based on optical microfiber knot resonatorOptik, 2018
- Fiber laser sensing system and its applicationsPhotonic Sensors, 2010
- Concentration-induced nonuniform power in tunable erbium-doped fiber lasersOptics Letters, 2004
- Linear cavity erbium-doped fiber laser with over 100 nm tuning rangeOptics Express, 2003
- Distributed-feedback fiber laser sensor for simultaneous strain and temperature measurements operating in the radio-frequency domainApplied Optics, 2001
- High-gain erbium-doped traveling-wave fiber amplifierOptics Letters, 1987
- Stimulated Optical Radiation in RubyNature, 1960