Susana Novais
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Susana Novais has a total of 125 co-authors. Here are the top co-authors by number of shared publications:
- Orlando Frazão
INESC TEC—Institute for Systems and Computer Engineering, Technology and Science, 4169-007 Porto, Portugal
27 shared publications - Susana Silva
INESC TEC - Institute for Systems and Computer Engineering, Technology and Science, Porto, Portugal
18 shared publications Susana Silva
10 shared publications- Liliana Soares
INESC TEC—Institute for Systems and Computer Engineering, Technology and Science, 4169-007 Porto, Portugal
9 shared publications Cristina Cunha
Department of Physics and Astronomy, Faculty of Sciences of University of Porto, Porto, Portugal
7 shared publications- Joao Lemos Pinto
Department of Physics and I3N, University of Aveiro, Campus de Santiago, 3810-193 Aveiro, Portugal
7 shared publications
Latest Publications
- Open Access
Multimode Fiber-Tip Interferometry for Time- and Frequency-Domain Analysis of Droplet Evaporation
This work presents an experimental investigation of droplet evaporation dynamics using a step-index multimode fiber-tip (MMF) interferometer. Distilled water, ethanol, isopropyl alcohol (IPA), and their binary mixtures with water were analyzed through complementary frequency- and time-domain approaches. Fast Fourier Transform (FFT) analysis was used to identify the dominant spectral components over selected evaporation intervals, while the instantaneous phase obtained from the analytic signal was used to track time-dependent variations in the optical response. For water, dominant components at 8.34 and 9.87 Hz corresponded to thickness-variation rates of −4.85 and −5.75 µm/s, respectively. Ethanol exhibited a dominant component at 15.8 Hz, corresponding to −9.01 µm/s, whereas IPA showed components at 13.2 and 34.8 Hz, associated with rates of −7.46 and −19.6 µm/s. Binary mixtures exhibited multiple spectral components and stronger temporal variability, indicating a nonstationary optical response during evaporation. The frequency- and time-domain results therefore provide complementary descriptions: the FFT identifies the dominant components over the selected interval, whereas instantaneous-phase analysis reveals their temporal evolution. Because the analysis was performed over short, selected evaporation intervals, the refractive index was assumed to remain approximately constant, and the measured phase variations were therefore attributed predominantly to changes in droplet thickness. The retrieved values are consequently interpreted as thickness-variation rates rather than direct mass-loss rates. The proposed approach provides a simple and compact method for monitoring droplet evaporation.
Open AccessMultimode Fiber-Tip Interferometry for Time- and Frequency-Domain Analysis of Droplet Evaporation
This work presents an experimental investigation of droplet evaporation dynamics using a step-index multimode fiber-tip (MMF) interferometer. Distilled water, ethanol, isopropyl alcohol (IPA), and their binary mixtures with water were analyzed through complementary frequency- and time-domain approaches. Fast Fourier Transform (FFT) analysis was used to identify the dominant spectral components over selected evaporation intervals, while the instantaneous phase obtained from the analytic signal was used to track time-dependent variations in the optical response. For water, dominant components at 8.34 and 9.87 Hz corresponded to thickness-variation rates of −4.85 and −5.75 µm/s, respectively. Ethanol exhibited a dominant component at 15.8 Hz, corresponding to −9.01 µm/s, whereas IPA showed components at 13.2 and 34.8 Hz, associated with rates of −7.46 and −19.6 µm/s. Binary mixtures exhibited multiple spectral components and stronger temporal variability, indicating a nonstationary optical response during evaporation. The frequency- and time-domain results therefore provide complementary descriptions: the FFT identifies the dominant components over the selected interval, whereas instantaneous-phase analysis reveals their temporal evolution. Because the analysis was performed over short, selected evaporation intervals, the refractive index was assumed to remain approximately constant, and the measured phase variations were therefore attributed predominantly to changes in droplet thickness. The retrieved values are consequently interpreted as thickness-variation rates rather than direct mass-loss rates. The proposed approach provides a simple and compact method for monitoring droplet evaporation.
- 22 May 2025
- Published by SPIE-Intl Soc Optical Eng
- p. 55
Intensity-based refractive index sensor using sliced fiber Bragg grating
- 22 May 2025
- Published by SPIE-Intl Soc Optical Eng
- p. 55
Intensity-based refractive index sensor using sliced fiber Bragg grating
- Open Access
- 31 October 2024
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 309, 10019
In-situ temperature monitorization in oscillatory flow crystallizer using optical fiber sensors with a Bragg grating inscribed at the fiber tips ends
Optical fiber sensors were implemented to measure in-situ temperature variations in an oscillatory flow crystallizer operating in continuous. The sensors were fabricated by cleaved in the middle 8 mm-length fiber Bragg gratings, forming tips with a Bragg grating of 4 mm inscribed at the fiber ends. The geometry of the sensors fabricated, with a diameter of 125 μm, allowed the temperature monitorization of the process flow, inside the crystallizer, at four different points: input, two intermediate points, and output. The results revealed that the proposed technology allows to perform an in-situ and in line temperature monitorization, during all the crystallization process, as an alternative to more expensive and complex technology.
- 31 October 2024
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 309, 10019
Open AccessIn-situ temperature monitorization in oscillatory flow crystallizer using optical fiber sensors with a Bragg grating inscribed at the fiber tips ends
Optical fiber sensors were implemented to measure in-situ temperature variations in an oscillatory flow crystallizer operating in continuous. The sensors were fabricated by cleaved in the middle 8 mm-length fiber Bragg gratings, forming tips with a Bragg grating of 4 mm inscribed at the fiber ends. The geometry of the sensors fabricated, with a diameter of 125 μm, allowed the temperature monitorization of the process flow, inside the crystallizer, at four different points: input, two intermediate points, and output. The results revealed that the proposed technology allows to perform an in-situ and in line temperature monitorization, during all the crystallization process, as an alternative to more expensive and complex technology.
- Open Access
- 31 October 2024
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 309, 10015
Glucose concentration detection using a low-cost Raman Spectroscopy Kit
Raman technology offers a cutting-edge approach to measuring glucose solutions, providing precise and non-invasive analysis. By probing the vibrational energy levels of molecular bonds, Raman technology generates a unique spectral fingerprint that allows for the accurate determination of glucose concentrations. This study proposes the use of Raman spectroscopy to identify different glucose concentrations through the detection of Raman fingerprints. As expected, higher concentrations of glucose in the solution conducted to higher peak bands, indicating more glucose molecules interacting with light and consequently increasing the magnitude of inelastic scattering. This non-destructive approach preserves sample integrity and facilitates rapid analysis, making it suitable for various applications in biomedical research, pharmaceutical development, and food science.
- 31 October 2024
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 309, 10015
Open AccessGlucose concentration detection using a low-cost Raman Spectroscopy Kit
Raman technology offers a cutting-edge approach to measuring glucose solutions, providing precise and non-invasive analysis. By probing the vibrational energy levels of molecular bonds, Raman technology generates a unique spectral fingerprint that allows for the accurate determination of glucose concentrations. This study proposes the use of Raman spectroscopy to identify different glucose concentrations through the detection of Raman fingerprints. As expected, higher concentrations of glucose in the solution conducted to higher peak bands, indicating more glucose molecules interacting with light and consequently increasing the magnitude of inelastic scattering. This non-destructive approach preserves sample integrity and facilitates rapid analysis, making it suitable for various applications in biomedical research, pharmaceutical development, and food science.
- 28 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (24) , 40896-40903
Novel Digital Signal Processing Method for Data Acquired From Low Coherence Interferometry
The aim of this work is to introduce a novel digital signal processing method for data acquired using Low Coherence Interferometry (LCI) with a 1 kHz actuator oscillation frequency. Convolution and correlation operations are employed as efficient filters, reducing computational complexity for multi-layer filtering. An envelope filtering technique is developed to address discrepancies in peak signal determination caused by non-linear actuator motion. Additionally, a phase linearization method is presented to normalize the peak position relative to the actuator signal. Experimental results demonstrate a significant signal-to-noise ratio (SNR) improvement of 50 dB. Long-term measurements reveal an 11 dB noise reduction for frequencies below 1 mHz. This research enables LCI implementation at sampling rates of at least 1 kHz and expands its applicability to extreme measurement conditions.
- 28 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (24) , 40896-40903
Novel Digital Signal Processing Method for Data Acquired From Low Coherence Interferometry
The aim of this work is to introduce a novel digital signal processing method for data acquired using Low Coherence Interferometry (LCI) with a 1 kHz actuator oscillation frequency. Convolution and correlation operations are employed as efficient filters, reducing computational complexity for multi-layer filtering. An envelope filtering technique is developed to address discrepancies in peak signal determination caused by non-linear actuator motion. Additionally, a phase linearization method is presented to normalize the peak position relative to the actuator signal. Experimental results demonstrate a significant signal-to-noise ratio (SNR) improvement of 50 dB. Long-term measurements reveal an 11 dB noise reduction for frequencies below 1 mHz. This research enables LCI implementation at sampling rates of at least 1 kHz and expands its applicability to extreme measurement conditions.
- Open Access
Phase-Shifted Fiber Bragg Grating by Selective Pitch Slicing
This paper presents a new type of phase-shifted Fiber Bragg Grating (FBG): the sliced-FBG (SFBG). The fabrication process involves cutting a standard FBG inside its grating region. As a result, the last grating pitch is shorter than the others. The optical output signal consists of the overlap between the FBG reflection and the reflection at the fiber-cleaved tip. This new fiber optic device has been studied as a vibration sensor, allowing for the characterization of this sensor in the frequency range of 150 Hz to 70 kHz. How the phase shift in the FBG can be controlled by changing the length of the last pitch is also shown. This device can be used as a filter and a sensing element. As a sensing element, we will demonstrate its application as a vibration sensor that can be utilized in various applications, particularly in monitoring mechanical structures.
Open AccessPhase-Shifted Fiber Bragg Grating by Selective Pitch Slicing
This paper presents a new type of phase-shifted Fiber Bragg Grating (FBG): the sliced-FBG (SFBG). The fabrication process involves cutting a standard FBG inside its grating region. As a result, the last grating pitch is shorter than the others. The optical output signal consists of the overlap between the FBG reflection and the reflection at the fiber-cleaved tip. This new fiber optic device has been studied as a vibration sensor, allowing for the characterization of this sensor in the frequency range of 150 Hz to 70 kHz. How the phase shift in the FBG can be controlled by changing the length of the last pitch is also shown. This device can be used as a filter and a sensing element. As a sensing element, we will demonstrate its application as a vibration sensor that can be utilized in various applications, particularly in monitoring mechanical structures.
- 20 June 2024
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12999, 6-11
Coreless silica fiber sensor based on self-image theory and coated with graphene oxide
This work provides a method that combines graphene oxide coating and self-image theory to improve the sensitivity of optical sensors. The sensor is designed specifically to measure the amount of glucose present quantitatively in aqueous solutions that replicate the range of glucose concentrations found in human saliva. COMSOL Multiphysics 6.0 was used to simulate the self-imaging phenomenon using a coreless silica fiber (CSF). For high-quality self-imaging, the second and fourth self-imaging points are usually preferred because of their higher coupling efficiency, which increases the sensor sensitivity. However, managing the fourth self-image is more difficult because it calls for a longer CSF length. As a result, the first and second self-image points were the focus of the simulation in this work. After the simulation, using the Layerby- Layer method, the sensor was constructed to a length that matched the second self-image point (29.12 mm) and coated with an 80 μm/mL graphene oxide layer. When comparing uncoated and graphene oxide-covered sensors to measure glucose in liquids ranging from 25 to 200 mg/dL, one bilayer of polyethyleneimine/graphene demonstrated an eight-fold improvement in sensitivity. The final sensor, built on graphene oxide, showed stability with a low standard deviation of 0.6 pm/min. It also showed sensitivity at 10.403 ± 0.004 pm/(mg/dL) with a limit of detection of 9.15 mg/dL.
- 20 June 2024
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12999, 6-11
Coreless silica fiber sensor based on self-image theory and coated with graphene oxide
This work provides a method that combines graphene oxide coating and self-image theory to improve the sensitivity of optical sensors. The sensor is designed specifically to measure the amount of glucose present quantitatively in aqueous solutions that replicate the range of glucose concentrations found in human saliva. COMSOL Multiphysics 6.0 was used to simulate the self-imaging phenomenon using a coreless silica fiber (CSF). For high-quality self-imaging, the second and fourth self-imaging points are usually preferred because of their higher coupling efficiency, which increases the sensor sensitivity. However, managing the fourth self-image is more difficult because it calls for a longer CSF length. As a result, the first and second self-image points were the focus of the simulation in this work. After the simulation, using the Layerby- Layer method, the sensor was constructed to a length that matched the second self-image point (29.12 mm) and coated with an 80 μm/mL graphene oxide layer. When comparing uncoated and graphene oxide-covered sensors to measure glucose in liquids ranging from 25 to 200 mg/dL, one bilayer of polyethyleneimine/graphene demonstrated an eight-fold improvement in sensitivity. The final sensor, built on graphene oxide, showed stability with a low standard deviation of 0.6 pm/min. It also showed sensitivity at 10.403 ± 0.004 pm/(mg/dL) with a limit of detection of 9.15 mg/dL.
- Open Access
Linear Fiber Laser Configurations for Optical Concentration Sensing in Liquid Solutions
In this study, different configurations based on linear fiber lasers were proposed and experimentally demonstrated to measure the concentration of liquid solutions. Samples of paracetamol liquid solutions with different concentrations, in the range from 52.61 to 201.33 g/kg, were used as a case-study. The optical gain was provided by a commercial bidirectional Erbium-Doped Fiber Amplifier (EDFA) and the linear cavity was obtained using two commercial Fiber Bragg Gratings (FBGs). The main difference of each configuration was the coupling ratio of the optical coupler used to extract the system signal. The sensing head corresponded to a Single-Mode Fiber (SMF) tip that worked as an intensity sensor. The results reveal that, despite the optical coupler used (50:50, 60:40, 70:30 or 80:20), all the configurations reached the laser condition, however, the concentration sensing was only possible using a laser drive current near to the threshold value. The configurations using a 70:30 and an 80:20 optical coupler allowed paracetamol concentration measurements with a higher sensitivity of () pW/(g/kg) to be performed. In terms of resolution, the highest value obtained was 1.75 g/kg, when it was extracted at 20% of the output power to the linear cavity fiber laser configuration.Open AccessLinear Fiber Laser Configurations for Optical Concentration Sensing in Liquid Solutions
In this study, different configurations based on linear fiber lasers were proposed and experimentally demonstrated to measure the concentration of liquid solutions. Samples of paracetamol liquid solutions with different concentrations, in the range from 52.61 to 201.33 g/kg, were used as a case-study. The optical gain was provided by a commercial bidirectional Erbium-Doped Fiber Amplifier (EDFA) and the linear cavity was obtained using two commercial Fiber Bragg Gratings (FBGs). The main difference of each configuration was the coupling ratio of the optical coupler used to extract the system signal. The sensing head corresponded to a Single-Mode Fiber (SMF) tip that worked as an intensity sensor. The results reveal that, despite the optical coupler used (50:50, 60:40, 70:30 or 80:20), all the configurations reached the laser condition, however, the concentration sensing was only possible using a laser drive current near to the threshold value. The configurations using a 70:30 and an 80:20 optical coupler allowed paracetamol concentration measurements with a higher sensitivity of () pW/(g/kg) to be performed. In terms of resolution, the highest value obtained was 1.75 g/kg, when it was extracted at 20% of the output power to the linear cavity fiber laser configuration. - Open Access
- 1 February 2024
- Published by MDPI AG in Preprints.org
Linear Fiber Laser Configurations for Optical Concentration Sensing in Liquid Solutions
In this study, different configurations based on linear fiber lasers were proposed and experimentally demonstrated to measure the concentration of paracetamol liquid solutions in a range of 52.61 to 201.33 g/kg. The optical gain was provided by a commercial bidirectional Erbium-Doped Fiber Amplifier (EDFA) and the linear cavity was obtained using two commercial Fiber Bragg Gratings (FBGs). The main difference of each configuration was the coupling ratio of the optical coupler used to extract the system signal. The sensing head corresponded to a Single-Mode Fiber (SMF) tip that worked as an intensity sensor. The results reveal that, despite the optical coupler used (50:50, 60:40, 70:30 or 80:20), all the configurations reached the laser condition, however, the concentration sensing was only possible using a laser drive current near to the threshold value. The configurations using a 70:30 and an 80:20 optical coupler allowed to perform paracetamol concentration measurements with a higher sensitivity of (-3.00±0.24) pW/(g/kg). In terms of resolution, the highest value obtained was 1.75 g/kg, when it was extracted 20% of the output power to the linear cavity fiber laser configuration.
- 1 February 2024
- Published by MDPI AG in Preprints.org
Open AccessLinear Fiber Laser Configurations for Optical Concentration Sensing in Liquid Solutions
In this study, different configurations based on linear fiber lasers were proposed and experimentally demonstrated to measure the concentration of paracetamol liquid solutions in a range of 52.61 to 201.33 g/kg. The optical gain was provided by a commercial bidirectional Erbium-Doped Fiber Amplifier (EDFA) and the linear cavity was obtained using two commercial Fiber Bragg Gratings (FBGs). The main difference of each configuration was the coupling ratio of the optical coupler used to extract the system signal. The sensing head corresponded to a Single-Mode Fiber (SMF) tip that worked as an intensity sensor. The results reveal that, despite the optical coupler used (50:50, 60:40, 70:30 or 80:20), all the configurations reached the laser condition, however, the concentration sensing was only possible using a laser drive current near to the threshold value. The configurations using a 70:30 and an 80:20 optical coupler allowed to perform paracetamol concentration measurements with a higher sensitivity of (-3.00±0.24) pW/(g/kg). In terms of resolution, the highest value obtained was 1.75 g/kg, when it was extracted 20% of the output power to the linear cavity fiber laser configuration.