Wearable Flexible Radio Frequency Filtering System for Muscle Contraction Monitoring
Open Access
- 18 January 2024
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Microwaves
- Vol. 4 (2) , 193-203
Abstract
This paper introduces a dual band-pass and dual band-stop filter that is designed along its flexible back-end circuitry to sense and monitor muscle contractions. The filter and its back-end circuit are proposed to be wearable, flexible, and stretchable. The presented design is composed of several logarithmically scaled spiral-shaped defected ground structures (DGS) located along the ground plane of a co-planar waveguide transmission line. In addition, U-shaped slots are integrated within the transmission line to maintain the sensing operation of the filter when its structure is stretched. The entire structure is fabricated on a multi-part flexible Polyethylene Terephthalate (PET) substrate and its stretchable configuration is enabled through the integration of a Room-Temperature-Vulcanizing (RTV) silicon substrate. Such stretchable ability is obtained through the movement of the multiple parts that compose the filter and is exhibited by the tuning of its band-pass and band-stop frequencies of operation between 1 GHz and 4 GHz. Correspondingly, the stretchable ability of the filter is also indicated by the change in magnitudes of its reflection and transmission coefficients. As a result, for the band-pass operation, the insertion loss of the flexible wearable filter, placed above the human arm, at the first frequency (1.39 GHz) is −1.95 dB with a tuning range of 590 MHz, and at the second frequency (2.68 GHz) −1.94 dB with a tuning range of 330 MHz. The change in the response of the presented system is proportional to the intensity of the muscle contraction. To capture this change, a custom-designed integrated flexible back-end circuit interrogates the sensor, collects the magnitudes of the reflection and transmission coefficients, and outputs corresponding voltages. As a result, monitoring the output voltage of the back-end circuit indicates the muscle contraction level, which is sensed from the stretching movement of the filter's structure. The back-end circuit and the sensor are fabricated and tested over multiple measurement cycles where the ability of the sensor to track muscle contraction is demonstrated.Keywords
Funding Information
- University Research Board
- American University of Beirut
This publication has 34 references indexed in Scilit:
- Multifunctional Bandpass Filter/Displacement Sensor ComponentIEEE Access, 2023
- Embroidered wearable Antenna-based sensor for Real-Time breath monitoringMeasurement, 2022
- A Non-Invasive Flexible Glucose Monitoring Sensor Using a Broadband Reject FilterIEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology, 2020
- Training induced fatigability assessed by sEMG in Pre-Olympic ice-skatersScientific Reports, 2020
- Complementary Split-Ring Resonator (CSRR)-Loaded Sensor Array to Detect Multiple Cracks: Shapes, Sizes, and Positions on Metallic SurfaceIEEE Access, 2020
- Real-time pressure mapping smart insole system based on a controllable vertical pore dielectric layerMicrosystems & Nanoengineering, 2020
- Design and Optimization of a Slotted Monopole Antenna for Ultra-Wide Band Body Centric Imaging ApplicationsIEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology, 2020
- Differential Narrow Bandpass Microstrip Filter Design for Material and Liquid Purity InterrogationIEEE Sensors Journal, 2019
- Microwave sensor for non‐invasive glucose measurements design and implementation of a novel linearIET Wireless Sensor Systems, 2015
- Polycrystalline aggregates in the thin-wire configurationJournal of Applied Physics, 2011