JCJoseph Costantine

Joseph Costantine

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Joseph Costantine has a total of 89 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Volumetric Near-Field Electromagnetic Sensing of Creatinine in Urine Using a 3D-Printed Bifilar Helical Platform

    by Rayan Al-Sayed Ali, Joseph Costantine, Youssef Tawk, Rouwaida Kanj, Joanna Ghaddar, Fatima Asadallah, Nassim Fares, Dania Chelala, Assaad A. Eid

    This paper presents a microwave sensing platform for quantitative evaluation of creatinine concentration in urine using a 3D-printed bifilar helical resonant structure. The proposed sensing system integrates two conductive helices with a slotted cylindrical shell incorporating volumetric split-ring resonators, enabling enhanced confinement of near-field electromagnetic energy within the sensing region. This design strengthens the interaction between the electromagnetic fields and the urine sample, resulting in increased sensitivity to variations in creatinine concentration. The sensing structure is fabricated using precision additive manufacturing to ensure high reproducibility and stable electromagnetic performance. Operating in the 4–6.5 GHz frequency range, the sensor response is characterized through measured scattering parameters, which are processed using artificial intelligence techniques for both regression and classification tasks. Gaussian Process regression is employed to estimate creatinine concentration, achieving a mean absolute relative difference (MARD) of 10% for artificial urine samples, between 6.94% and 10% for ex-vivo rat studies, and 7.2% for clinical human urine samples. In addition, a support vector machine classifier is used to detect creatinine in the presence of common interferers, achieving an accuracy ranging from 92.5% to 97.5%, a sensitivity between 90% and 100%, and a specificity between 91.6% and 100%. The proposed platform demonstrates a robust, reagent-free, and noninvasive approach for real-time creatinine monitoring, offering promising potential for future point-of-care diagnostic applications and early assessment of kidney function.

  • SignScribe: A Wearable Antenna for Sign Language Transcription

    by Z. W. Attoun, J. B. Salameh, P. N. Saade, R. E. Mezher, G. G. Abou Jaoude, J. Costantine, Y. Tawk

  • Open Access

    Single and Dual Helical Polarizers for Millimeter-Wave Horn Antennas

    by Maya Al Ajam, Youssef Tawk, Joseph Costantine

    This paper presents a helical-based polarizer integrated into the aperture of a pyramidal horn antenna, designed to convert linearly polarized radiated fields into either right-or left-handed circular polarization over two distinct bands. The integrated polarizer is entirely passive and functions as a parasitic element, positioned between the waveguide launcher and the radiating aperture. The polarization type is determined by the winding orientation of the integrated helical wire. Two distinct approaches are explored for polarization conversion. In the first approach, a single helical wire is aligned along the center of the horn aperture and designed to provide polarization conversion with a peak realized gain of 14.3 dBic over the frequency range of 26 GHz to 32 GHz. The second method incorporates two helical wires as polarizers: one centered in the aperture and a second, oppositely wound, placed along the horns sidewall. This configuration provides polarization conversion with a maximum realized gain of 15.25 dBic between 33 GHz and 37 GHz. For both bands, a cross-polarization level that goes beyond 23 dB is achieved. Experimental testing of both designs demonstrates a strong agreement between simulated and measured results, confirming the effectiveness of the proposed polarization conversion technique.

  • Body-Responsive Electromagnetic Sensing for Future Health-Care Diagnostics: Toward new frontiers of noninvasive biomarker monitoring [Bioelectromagnetics]

    by Jessica Hanna, Joseph Costantine, Youssef Tawk, Rouwaida Kanj, Assaad A. Eid

    Body-responsive sensing using electromagnetic waves transforms radio frequency-based sensors and medical devices into interactive tools that disseminate the body’s interaction with electromagnetic fields and correlate it with medical diagnostics. This sensing offers non-invasive, real-time insights into the human body, revolutionizing disease detection, continuous monitoring, and personalized healthcare management. Unlike traditional methods often burdened by cost and radiation risk, electromagnetic sensors seamlessly integrated into medical devices like implants, wearables, and imaging equipment, showcase remarkable benefits in biomarker detection, vital signs tracking, and early cancer screening. In this paper, we delve deep into the world of electromagnetic sensors and their applications in healthcare diagnostics. Moreover, we explore the challenges and prospects of these electromagnetic devices, paving the way for their seamless integration into clinical practice.


  • Wireless Continuous Glucose Monitoring Using V-Band Circularly Polarized Directive Antenna Arrays in a Transmit/Receive System

    by Hoda M. Farhat, Joseph Costantine, Youssef Tawk, Rouwaida Kanj, Ali H. Ramadan, Batoul Dia, Joanna Ghaddar, Assaad A. Eid

    This paper discusses the design of circularly polarized V-band antenna arrays for continuous and wireless blood glucose monitoring. The proposed system is designed to be integrated into earrings to sense glucose variations at a distance and without physical contact with the sensed area. Sensing occurs when one antenna array transmits its radiated beam across the neck veins to be received by a second antenna array integrated into a second earring on the other side of the neck. The analysis of received signals versus transmitted signals using machine learning algorithms enables this system to track glucose variation in blood instantaneously with great fidelity. Experiments executed on fetal bovine serum solutions and in-vivo experiments on animal models demonstrate high accuracy in the ability of the proposed antenna array system to continuously track glucose concentrations across the diabetic range [30mg/dl - 500mg/dl]. Furthermore, executed clinical studies reveal an accuracy of 94.82% in continuously monitoring glucose variations.


  • Open Access

    A Groove Gap Waveguide Feeding Network for Dual-Circularly Polarized Antenna Arrays

    by Zeina Al Masri, Ahmad Jabri, Youssef Tawk, Joseph Costantine

    This paper presents a groove gap waveguide structure designed to serve as a feeding network for dual circularly polarized antenna arrays in the millimeter wave spectrum (28-32 GHz). The proposed structure comprises four groove gap waveguide elements arranged in a cross-shaped configuration. A turnstile integrated into the middle position of the structure divides the incoming RF signal into these four waveguide elements. Four matching posts are incorporated at the end of the various groove gap waveguide elements to route each corresponding RF signal to four WR-28 waveguide sections. These four sections form the output ports of the feeding network. The appropriate design of the pin distributions along the four groove gap elements allows the entire feeding network to achieve a specific phase shift between the output ports. As a proof of concept, the proposed feeding network is connected to a dual circularly polarized antenna array composed of four sub-arrays. Two of these sub-arrays emit right-handed circularly polarized waves, while the other two are designed to provide left-handed circularly polarized waves. A prototype of the feeding network demonstrates its ability to produce the needed circularly polarized radiation for a given distribution of the pins along the various groove gap elements. The results show that the feeding network can achieve an insertion loss as low as 0.55 dB with a good impedance matching across the entire operational bandwidth. In addition, when the fabricated feeding network is connected to the dual-circularly polarized antenna prototype, a maximum realized gain of 15.14 dBic is obtained.


  • Monostatic Free-Space Method for Relative Permittivity Determination Using Horn Antenna Near-Field Measurements

    by Hassan Shwaykani, Joseph Costantine, Ali El-Hajj, Mohammed Al-Husseini

    This paper presents a free-space method for the measurement of the relative permittivity of planar low-loss materials, using one-port scattering parameters. The proposed method estimates the dielectric constant value of a material under test (MUT) with a thickness of more than half of a wavelength, placed in front of an X-band pyramidal-horn antenna. The calculation leverages the frequency points where the reflection coefficient's magnitude (|S 11 |) is the lowest while disregarding any system pre-calibration measurements. The free-space setup was tested on multiple materials with a wide range of electric permittivity values, where accurate estimation results of dielectric constants were obtained.


  • Open Access

    Wearable Flexible Radio Frequency Filtering System for Muscle Contraction Monitoring

    by Zaynab Attoun, Nader Shafi, Youssef Tawk, Joseph Costantine, Elie Shammas

    This paper introduces a dual band-pass and dual band-stop filter that is designed along its flexible back-end circuitry to sense and monitor muscle contractions. The filter and its back-end circuit are proposed to be wearable, flexible, and stretchable. The presented design is composed of several logarithmically scaled spiral-shaped defected ground structures (DGS) located along the ground plane of a co-planar waveguide transmission line. In addition, U-shaped slots are integrated within the transmission line to maintain the sensing operation of the filter when its structure is stretched. The entire structure is fabricated on a multi-part flexible Polyethylene Terephthalate (PET) substrate and its stretchable configuration is enabled through the integration of a Room-Temperature-Vulcanizing (RTV) silicon substrate. Such stretchable ability is obtained through the movement of the multiple parts that compose the filter and is exhibited by the tuning of its band-pass and band-stop frequencies of operation between 1 GHz and 4 GHz. Correspondingly, the stretchable ability of the filter is also indicated by the change in magnitudes of its reflection and transmission coefficients. As a result, for the band-pass operation, the insertion loss of the flexible wearable filter, placed above the human arm, at the first frequency (1.39 GHz) is −1.95 dB with a tuning range of 590 MHz, and at the second frequency (2.68 GHz) −1.94 dB with a tuning range of 330 MHz. The change in the response of the presented system is proportional to the intensity of the muscle contraction. To capture this change, a custom-designed integrated flexible back-end circuit interrogates the sensor, collects the magnitudes of the reflection and transmission coefficients, and outputs corresponding voltages. As a result, monitoring the output voltage of the back-end circuit indicates the muscle contraction level, which is sensed from the stretching movement of the filter's structure. The back-end circuit and the sensor are fabricated and tested over multiple measurement cycles where the ability of the sensor to track muscle contraction is demonstrated.


  • Open Access

    Enabling an On-Demand Frequency Doubling Mechanism Through a Capacitively Loaded Miniaturized Diplexer

    by Karim Cheayto, Zaynab Attoun, Youssef Tawk, Joseph Costantine

    This paper presents a diplexer design that generates a pair of fundamental and harmonic frequencies. The diplexer is based on a capacitively loaded resonator that is able to reconfigure its frequency pair with respect to capacitive loading. The system shows a fundamental and harmonic frequency pair of 5 GHz and 10 GHz without any capacitive loading and 2.5 GHz and 5 GHz when loaded with a 1pF/0.5 pF capacitor pair. The complete system is fabricated and tested where good agreement is obtained between the measured and computed results. The testing is performed for the two states of the diplexer, when the diplexer is unloaded and after loading it with the capacitor pairs. For both unloaded and loaded scenarios, the proposed design produces a maximum insertion loss of 0.6 dB with an isolation of at least 35 dB at the corresponding operational frequencies. The structure is also able to provide a minimum return loss of 25 dB at each port. The proposed diplexer is then integrated with a frequency doubler chip and the full system maintains an acceptable efficiency along with a high conversion gain of approximately 15 dB.