Influence of myocardial region of interest definition on quantitative analysis of planar 123I-mIBG images
- 29 January 2013
- journal article
- research article
- Published by Springer Nature in European Journal of Nuclear Medicine and Molecular Imaging
- Vol. 40 (4) , 558-564
Abstract
Purpose In planar 123I-mIBG myocardial imaging, definition of the heart region of interest (ROI) is a critical step in quantifying uptake. The present study evaluated the impact of changes in heart ROI size on quantitative results in subjects with good and poor uptake. Methods Reference irregular whole-heart and square upper mediastinum ROIs were defined visually on 531 planar 123I-mIBG images. Based on the reference heart ROI, an automated program created two other ROIs: one larger (+1 pixel) and one smaller (−1 pixel), the stated numbers representing the spacing intervals between each epicardial boundary pixel. Two additional smaller ROIs (−2 and −3 pixels) were drawn for the 100 images (19 %) with a heart/mediastinum (H/M) ratio ≤1.30. The number of pixels, the counts per pixel, and the H/M ratio for each heart ROI were calculated and compared to that in the reference ROI. Washout rate and changes as a function of ROI size were also calculated for 110 subjects who had both early and late images. Results The mean changes in heart ROI size ranged from +19.0 % for the +1 pixel to −44.4 % for the −3 pixels ROI. For the +1 and −1 pixel ROIs, mean relative counts per pixel changes were −1.2 % and +0.7 %, respectively, with corresponding ranges of change in the H/M ratio of −0.12 to +0.05 and −0.05 to +0.11. For scans with H/M ratio ≤1.30, mean relative counts per pixel changes were 0, 0, −0.7 %, and −1.4 % for the four ROIs, with range of change in the H/M ratio from −0.13 to +0.05. Mean washout rates were almost identical for the reference ROIs (45.0 %) and the +1 pixel and −1 pixel heart ROIs (44.9 % and 45.1 %, respectively). Conclusion Significant changes in the size of the best visually defined heart ROI produce minimal, clinically inconsequential changes in the H/M ratio and washout rate, even in subjects with significantly reduced myocardial uptake of 123I-mIBG.Keywords
This publication has 24 references indexed in Scilit:
- Myocardial Iodine-123 Meta-Iodobenzylguanidine Imaging and Cardiac Events in Heart FailureJACC, 2010
- 123I-meta-iodobenzylguanidine in patients with chronic heart failure: technical aspects, conceptual issues, and future prospectsNuclear Medicine Communications, 2009
- Impact of mediastinal, liver and lung 123I-metaiodobenzylguanidine (123I-MIBG) washout on calculated 123I-MIBG myocardial washoutEuropean Journal of Nuclear Medicine and Molecular Imaging, 2009
- 123 I- m IBG Scintigraphy to Predict Inducibility of Ventricular Arrhythmias on Cardiac Electrophysiology TestingCirculation: Cardiovascular Imaging, 2008
- Cardiac neuronal imaging: Application in the evaluation of cardiac diseaseJournal of Nuclear Cardiology, 2008
- Prognostic value of myocardial 123I-metaiodobenzylguanidine (MIBG) parameters in patients with heart failure: a systematic reviewEuropean Heart Journal, 2008
- Variations in 123I-metaiodobenzylguanidine (MIBG) late heart mediastinal ratios in chronic heart failure: a need for standardisation and validationEuropean Journal of Nuclear Medicine and Molecular Imaging, 2007
- Cardiac neurotransmission SPECT imagingJournal of Nuclear Cardiology, 2004
- Normal values and within-subject variability of cardiac I-123 MIBG scintigraphy in healthy individuals: implications for clinical studiesJournal of Nuclear Cardiology, 2004
- Cardiac 123I-MIBG uptake is affected by variable uptake in reference regionsNuclear Medicine Communications, 1996