Arnold F. Jacobson
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Arnold F. Jacobson has a total of 47 co-authors. Here are the top co-authors by number of shared publications:
Natalie Khutoryansky
10Research and Development, GE Healthcare, Princeton, New Jersey
3 shared publicationsDaya N. Manatunga
Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, USA
2 shared publications- Ernest V. Garciaf
Department of Radiology and Imaging Sciences, Emory University, Atlanta, USA
2 shared publications Ji Chen
Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, USA
2 shared publicationsJohn Lombard
GE Healthcare (A.F.J., J.L.), Princeton, New Jersey 08540
2 shared publications- Russell D. Folks
Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, GA, USA.
2 shared publications
Latest Publications
- 1 August 2014
- Published by Elsevier in Journal of Cardiac Failure
- Vol. 20 (8) , S17
Differences in Myocardial Sympathetic Innervation and Perfusion in Patients with Ischemic Versus Non-ischemic Heart Failure
- 1 August 2014
- Published by Elsevier in Journal of Cardiac Failure
- Vol. 20 (8) , S17
Differences in Myocardial Sympathetic Innervation and Perfusion in Patients with Ischemic Versus Non-ischemic Heart Failure
- 1 June 2013
- Published by Elsevier in Journal of Nuclear Cardiology
- Vol. 20 (3) , 406-414
Impact of age on myocardial uptake of 123I-mIBG in older adult subjects without coronary heart disease
- 1 June 2013
- Published by Elsevier in Journal of Nuclear Cardiology
- Vol. 20 (3) , 406-414
Impact of age on myocardial uptake of 123I-mIBG in older adult subjects without coronary heart disease
- 29 January 2013
- Published by Springer Nature in European Journal of Nuclear Medicine and Molecular Imaging
- Vol. 40 (4) , 558-564
Influence of myocardial region of interest definition on quantitative analysis of planar 123I-mIBG images
Purpose In planar 123I-mIBG myocardial imaging, definition of the heart region of interest (ROI) is a critical step in quantifying uptake. The present study evaluated the impact of changes in heart ROI size on quantitative results in subjects with good and poor uptake. Methods Reference irregular whole-heart and square upper mediastinum ROIs were defined visually on 531 planar 123I-mIBG images. Based on the reference heart ROI, an automated program created two other ROIs: one larger (+1 pixel) and one smaller (−1 pixel), the stated numbers representing the spacing intervals between each epicardial boundary pixel. Two additional smaller ROIs (−2 and −3 pixels) were drawn for the 100 images (19 %) with a heart/mediastinum (H/M) ratio ≤1.30. The number of pixels, the counts per pixel, and the H/M ratio for each heart ROI were calculated and compared to that in the reference ROI. Washout rate and changes as a function of ROI size were also calculated for 110 subjects who had both early and late images. Results The mean changes in heart ROI size ranged from +19.0 % for the +1 pixel to −44.4 % for the −3 pixels ROI. For the +1 and −1 pixel ROIs, mean relative counts per pixel changes were −1.2 % and +0.7 %, respectively, with corresponding ranges of change in the H/M ratio of −0.12 to +0.05 and −0.05 to +0.11. For scans with H/M ratio ≤1.30, mean relative counts per pixel changes were 0, 0, −0.7 %, and −1.4 % for the four ROIs, with range of change in the H/M ratio from −0.13 to +0.05. Mean washout rates were almost identical for the reference ROIs (45.0 %) and the +1 pixel and −1 pixel heart ROIs (44.9 % and 45.1 %, respectively). Conclusion Significant changes in the size of the best visually defined heart ROI produce minimal, clinically inconsequential changes in the H/M ratio and washout rate, even in subjects with significantly reduced myocardial uptake of 123I-mIBG.
- 29 January 2013
- Published by Springer Nature in European Journal of Nuclear Medicine and Molecular Imaging
- Vol. 40 (4) , 558-564
Influence of myocardial region of interest definition on quantitative analysis of planar 123I-mIBG images
Purpose In planar 123I-mIBG myocardial imaging, definition of the heart region of interest (ROI) is a critical step in quantifying uptake. The present study evaluated the impact of changes in heart ROI size on quantitative results in subjects with good and poor uptake. Methods Reference irregular whole-heart and square upper mediastinum ROIs were defined visually on 531 planar 123I-mIBG images. Based on the reference heart ROI, an automated program created two other ROIs: one larger (+1 pixel) and one smaller (−1 pixel), the stated numbers representing the spacing intervals between each epicardial boundary pixel. Two additional smaller ROIs (−2 and −3 pixels) were drawn for the 100 images (19 %) with a heart/mediastinum (H/M) ratio ≤1.30. The number of pixels, the counts per pixel, and the H/M ratio for each heart ROI were calculated and compared to that in the reference ROI. Washout rate and changes as a function of ROI size were also calculated for 110 subjects who had both early and late images. Results The mean changes in heart ROI size ranged from +19.0 % for the +1 pixel to −44.4 % for the −3 pixels ROI. For the +1 and −1 pixel ROIs, mean relative counts per pixel changes were −1.2 % and +0.7 %, respectively, with corresponding ranges of change in the H/M ratio of −0.12 to +0.05 and −0.05 to +0.11. For scans with H/M ratio ≤1.30, mean relative counts per pixel changes were 0, 0, −0.7 %, and −1.4 % for the four ROIs, with range of change in the H/M ratio from −0.13 to +0.05. Mean washout rates were almost identical for the reference ROIs (45.0 %) and the +1 pixel and −1 pixel heart ROIs (44.9 % and 45.1 %, respectively). Conclusion Significant changes in the size of the best visually defined heart ROI produce minimal, clinically inconsequential changes in the H/M ratio and washout rate, even in subjects with significantly reduced myocardial uptake of 123I-mIBG.
- Open Access
- 29 August 2011
- Published by Society of Nuclear Medicine in Journal of Nuclear Medicine Technology
- Vol. 39 (4) , 302-306
Survey of the Performance of Commercial Dose Calibrators for Measurement of 123I Activity
The accuracy with which 123I activity is measured by a dose calibrator depends on the composition and geometry of the source. The present study assessed the variability of current commercial dose calibrators in assaying liquid 123I samples. Methods: A calibration procedure for 123I measurement was performed on 177 dose calibrators (11 manufacturers) at 138 sites in North America and Europe. Using the standard 123I push-button or dial setting, activity in a 5-mL 123I calibration source in a 10-mL U.S. Pharmacopeia type 1 glass vial (actual activity previously determined using a National Institute of Standards and Technology–traceable standard metrology chamber) was measured. A portion of the source was then transferred to a plastic syringe (10-, 5-, and 3-mL sizes at different sites), and the activity in the syringe was measured. Calibration factors (CFs) for converting the dose calibrator readings to the reference activities were then determined for the vial and the syringes. Data were analyzed for all calibrators combined and based on device manufacturers. Measurements using a copper attenuator (sleeve) were made for a subset of 10 dose calibrators at sites that used these devices in clinical practice. Results: Mean CFs for the different measurements were as follows: 10-mL vial, 1.278; 10-mL syringe, 0.811; 5-mL syringe, 0.815; 3-mL syringe, 0.792. Almost half of the dose calibrators had vial CFs between 1.2 and 1.3 and 10-mL syringe CFs between 0.7 and 0.8, whereas less than 16% of the instruments had uncorrected readings within ±10% of the reference activities. Although there was a wide range of CFs for different calibrators using the copper sleeve, for each unit the CFs for the glass vial and the 10-mL plastic syringe were virtually identical. Conclusion: On most commercial dose calibrators, the standard 123I settings result in significant errors in activity measurements for sources in glass vials and plastic syringes. The difference in ionization chamber detection caused by the container composition (glass vs. plastic) is a much larger source of measurement variation than source volume or geometry.
- 29 August 2011
- Published by Society of Nuclear Medicine in Journal of Nuclear Medicine Technology
- Vol. 39 (4) , 302-306
Open AccessSurvey of the Performance of Commercial Dose Calibrators for Measurement of 123I Activity
The accuracy with which 123I activity is measured by a dose calibrator depends on the composition and geometry of the source. The present study assessed the variability of current commercial dose calibrators in assaying liquid 123I samples. Methods: A calibration procedure for 123I measurement was performed on 177 dose calibrators (11 manufacturers) at 138 sites in North America and Europe. Using the standard 123I push-button or dial setting, activity in a 5-mL 123I calibration source in a 10-mL U.S. Pharmacopeia type 1 glass vial (actual activity previously determined using a National Institute of Standards and Technology–traceable standard metrology chamber) was measured. A portion of the source was then transferred to a plastic syringe (10-, 5-, and 3-mL sizes at different sites), and the activity in the syringe was measured. Calibration factors (CFs) for converting the dose calibrator readings to the reference activities were then determined for the vial and the syringes. Data were analyzed for all calibrators combined and based on device manufacturers. Measurements using a copper attenuator (sleeve) were made for a subset of 10 dose calibrators at sites that used these devices in clinical practice. Results: Mean CFs for the different measurements were as follows: 10-mL vial, 1.278; 10-mL syringe, 0.811; 5-mL syringe, 0.815; 3-mL syringe, 0.792. Almost half of the dose calibrators had vial CFs between 1.2 and 1.3 and 10-mL syringe CFs between 0.7 and 0.8, whereas less than 16% of the instruments had uncorrected readings within ±10% of the reference activities. Although there was a wide range of CFs for different calibrators using the copper sleeve, for each unit the CFs for the glass vial and the 10-mL plastic syringe were virtually identical. Conclusion: On most commercial dose calibrators, the standard 123I settings result in significant errors in activity measurements for sources in glass vials and plastic syringes. The difference in ionization chamber detection caused by the container composition (glass vs. plastic) is a much larger source of measurement variation than source volume or geometry.
- Open Access
- 1 June 2010
- Published by The Endocrine Society in The Journal of Clinical Endocrinology & Metabolism
- Vol. 95 (6) , 2596-2606
123I-Meta-Iodobenzylguanidine Scintigraphy for the Detection of Neuroblastoma and Pheochromocytoma: Results of a Meta-Analysis
Context:123I-mIBG scintigraphy has been in clinical use for more than 20 yr for diagnostic assessment of patients with neural crest and neuroendocrine tumors. Prospective validation of the performance characteristics of this method has recently been published. Objective: A meta-analysis was performed to obtain best estimates of performance characteristics of 123I-mIBG imaging for the two most common applications, evaluation of patients with neuroblastoma and pheochromocytoma. Data Sources: Articles published between 1980 and 2007 were identified from searches of multiple computer databases, including MEDLINE, BIOSIS, EMBASE, and SciSearch. Study Selection: Primary inclusion criteria were: acceptable reference standard(s) for confirming subjects with disease (histopathology and/or a combination of imaging and catecholamine results); reference standards applied to all subjects who received 123I-mIBG; and data on a minimum of 16 patients confirmed to have or not have the disease(s) under consideration. Two physician reviewers independently evaluated all articles against the inclusion/exclusion criteria. Twenty-two of 100 articles reviewed were included in the final analysis. Data Extraction: The two reviewers extracted the data from eligible articles using a standardized form, capturing both study quality and efficacy information. Disagreements were resolved by consensus. Data Synthesis: Sensitivity of 123I-mIBG scans for detection of neuroblastoma was 97% [95% confidence interval (CI), 95 to 99%]; data were insufficient to estimate specificity. For pheochromocytoma, with application of the random-effects model, sensitivity and specificity were 94% (95% CI, 91–97%) and 92% (95% CI, 87–98%), respectively. Conclusion: Based upon the literature, 123I-mIBG scintigraphy has sensitivity and specificity greater than 90% for detection of neuroblastoma and pheochromocytoma.
- 1 June 2010
- Published by The Endocrine Society in The Journal of Clinical Endocrinology & Metabolism
- Vol. 95 (6) , 2596-2606
Open Access123I-Meta-Iodobenzylguanidine Scintigraphy for the Detection of Neuroblastoma and Pheochromocytoma: Results of a Meta-Analysis
Context:123I-mIBG scintigraphy has been in clinical use for more than 20 yr for diagnostic assessment of patients with neural crest and neuroendocrine tumors. Prospective validation of the performance characteristics of this method has recently been published. Objective: A meta-analysis was performed to obtain best estimates of performance characteristics of 123I-mIBG imaging for the two most common applications, evaluation of patients with neuroblastoma and pheochromocytoma. Data Sources: Articles published between 1980 and 2007 were identified from searches of multiple computer databases, including MEDLINE, BIOSIS, EMBASE, and SciSearch. Study Selection: Primary inclusion criteria were: acceptable reference standard(s) for confirming subjects with disease (histopathology and/or a combination of imaging and catecholamine results); reference standards applied to all subjects who received 123I-mIBG; and data on a minimum of 16 patients confirmed to have or not have the disease(s) under consideration. Two physician reviewers independently evaluated all articles against the inclusion/exclusion criteria. Twenty-two of 100 articles reviewed were included in the final analysis. Data Extraction: The two reviewers extracted the data from eligible articles using a standardized form, capturing both study quality and efficacy information. Disagreements were resolved by consensus. Data Synthesis: Sensitivity of 123I-mIBG scans for detection of neuroblastoma was 97% [95% confidence interval (CI), 95 to 99%]; data were insufficient to estimate specificity. For pheochromocytoma, with application of the random-effects model, sensitivity and specificity were 94% (95% CI, 91–97%) and 92% (95% CI, 87–98%), respectively. Conclusion: Based upon the literature, 123I-mIBG scintigraphy has sensitivity and specificity greater than 90% for detection of neuroblastoma and pheochromocytoma.
- Open Access
- 18 August 2009
- Published by Society of Nuclear Medicine in Journal of Nuclear Medicine
- Vol. 50 (9) , 1448-1454
Usefulness of 123I-MIBG Scintigraphy in the Evaluation of Patients with Known or Suspected Primary or Metastatic Pheochromocytoma or Paraganglioma: Results from a Prospective Multicenter Trial
Although 123I-MIBG has been in clinical use for the imaging of pheochromocytoma for many years, a large multicenter evaluation of this agent has never been performed. The present study was designed to provide a prospective confirmation of the performance of 123I-MIBG scintigraphy for the evaluation of patients with known or suspected primary or metastatic pheochromocytoma or paraganglioma. Methods: A total of 81 patients with a prior history of primary or metastatic pheochromocytoma or paraganglioma and 69 with suspected pheochromocytoma or paraganglioma based on symptoms of catecholamine excess, CT or MRI findings, or elevated catecholamine or metanephrine levels underwent whole-body planar and selected SPECT 24 h after the administration of 123I-MIBG. Images were independently interpreted by 3 masked readers, with consensus requiring agreement of at least 2 readers. Final diagnoses were based on histopathology, correlative imaging, catecholamine or metanephrine measurements, and clinical follow-up. Results: Among 140 patients with definitive diagnoses (91, disease present; 49, disease absent), 123I-MIBG planar scintigraphy had a sensitivity and specificity of 82%. For patients evaluated for suspected disease, sensitivity and specificity were 88% and 84%, respectively. For the subpopulations of adrenal (pheochromocytoma) and extraadrenal (paraganglioma) tumors, sensitivities were 88% and 67%, respectively. The addition of SPECT increased reader confidence but minimally affected sensitivity and specificity. Conclusion: This prospective study demonstrated a sensitivity of 82%−88% and specificity of 82%−84% for 123I-MIBG imaging used in the diagnostic assessment of primary or metastatic pheochromocytoma or paraganglioma.
- 18 August 2009
- Published by Society of Nuclear Medicine in Journal of Nuclear Medicine
- Vol. 50 (9) , 1448-1454
Open AccessUsefulness of 123I-MIBG Scintigraphy in the Evaluation of Patients with Known or Suspected Primary or Metastatic Pheochromocytoma or Paraganglioma: Results from a Prospective Multicenter Trial
Although 123I-MIBG has been in clinical use for the imaging of pheochromocytoma for many years, a large multicenter evaluation of this agent has never been performed. The present study was designed to provide a prospective confirmation of the performance of 123I-MIBG scintigraphy for the evaluation of patients with known or suspected primary or metastatic pheochromocytoma or paraganglioma. Methods: A total of 81 patients with a prior history of primary or metastatic pheochromocytoma or paraganglioma and 69 with suspected pheochromocytoma or paraganglioma based on symptoms of catecholamine excess, CT or MRI findings, or elevated catecholamine or metanephrine levels underwent whole-body planar and selected SPECT 24 h after the administration of 123I-MIBG. Images were independently interpreted by 3 masked readers, with consensus requiring agreement of at least 2 readers. Final diagnoses were based on histopathology, correlative imaging, catecholamine or metanephrine measurements, and clinical follow-up. Results: Among 140 patients with definitive diagnoses (91, disease present; 49, disease absent), 123I-MIBG planar scintigraphy had a sensitivity and specificity of 82%. For patients evaluated for suspected disease, sensitivity and specificity were 88% and 84%, respectively. For the subpopulations of adrenal (pheochromocytoma) and extraadrenal (paraganglioma) tumors, sensitivities were 88% and 67%, respectively. The addition of SPECT increased reader confidence but minimally affected sensitivity and specificity. Conclusion: This prospective study demonstrated a sensitivity of 82%−88% and specificity of 82%−84% for 123I-MIBG imaging used in the diagnostic assessment of primary or metastatic pheochromocytoma or paraganglioma.
- 1 August 2009
- Published by Elsevier in Journal of Nuclear Cardiology
- Vol. 16 (4) , 540-548
Influence of 99mTc-tetrofosmin SPECT myocardial perfusion imaging on the prediction of future adverse cardiac events
- 1 August 2009
- Published by Elsevier in Journal of Nuclear Cardiology
- Vol. 16 (4) , 540-548
Influence of 99mTc-tetrofosmin SPECT myocardial perfusion imaging on the prediction of future adverse cardiac events
- 30 January 2009
- Published by Wiley in Pediatric Blood & Cancer
- Vol. 52 (7) , 784-790
123I‐mIBG scintigraphy in patients with known or suspected neuroblastoma: Results from a prospective multicenter trial
Background: A prospective trial was conducted to confirm the diagnostic performance of 123I‐mIBG scintigraphy in patients with known or suspected neuroblastoma.Procedure: One hundred patients (mean age 4.7 years) were enrolled, 86 with a previous diagnosis of neuroblastoma, 13 with suspected disease based upon symptoms, imaging findings, and elevated catecholamines, and one adult with an abdominal tumor thought to be of neuroendocrine origin. All patients underwent whole‐body planar imaging 24 hr following IV administration of 1–10 mCi (37–370 MBq) 123I‐mIBG. SPECT imaging of the thorax/abdomen/pelvis was performed in 51 patients. Images were interpreted by three blinded readers, with consensus requiring agreement of at least two readers. Disease status was confirmed by histopathology, imaging results, catecholamine measurements, and follow‐up.Results: Sixty‐four patients had active disease, 30 were without disease, and 6 were judged indeterminate because of insufficient confirmatory data. 123I‐mIBG scintigraphy had a sensitivity of 88% (56/64) and specificity of 83% (25/30). Sensitivity was 91% (30/33) among the subset of subjects who had both planar and SPECT imaging. Among 53 patients with recent histopathology, sensitivity and specificity were 93% and 92%, respectively. Most false‐negative interpretations were in patients with minimal residual disease (n = 4), while false‐positive interpretations generally involved atypical adrenal or other physiological uptake (n = 4).Conclusions: This prospective multicenter trial of 123I‐mIBG scintigraphy documents high sensitivity and specificity of this imaging technique in patients with both newly diagnosed and previously treated neuroblastoma. Pediatr Blood Cancer 2009;52:784–790.
- 30 January 2009
- Published by Wiley in Pediatric Blood & Cancer
- Vol. 52 (7) , 784-790
123I‐mIBG scintigraphy in patients with known or suspected neuroblastoma: Results from a prospective multicenter trial
Background: A prospective trial was conducted to confirm the diagnostic performance of 123I‐mIBG scintigraphy in patients with known or suspected neuroblastoma.Procedure: One hundred patients (mean age 4.7 years) were enrolled, 86 with a previous diagnosis of neuroblastoma, 13 with suspected disease based upon symptoms, imaging findings, and elevated catecholamines, and one adult with an abdominal tumor thought to be of neuroendocrine origin. All patients underwent whole‐body planar imaging 24 hr following IV administration of 1–10 mCi (37–370 MBq) 123I‐mIBG. SPECT imaging of the thorax/abdomen/pelvis was performed in 51 patients. Images were interpreted by three blinded readers, with consensus requiring agreement of at least two readers. Disease status was confirmed by histopathology, imaging results, catecholamine measurements, and follow‐up.Results: Sixty‐four patients had active disease, 30 were without disease, and 6 were judged indeterminate because of insufficient confirmatory data. 123I‐mIBG scintigraphy had a sensitivity of 88% (56/64) and specificity of 83% (25/30). Sensitivity was 91% (30/33) among the subset of subjects who had both planar and SPECT imaging. Among 53 patients with recent histopathology, sensitivity and specificity were 93% and 92%, respectively. Most false‐negative interpretations were in patients with minimal residual disease (n = 4), while false‐positive interpretations generally involved atypical adrenal or other physiological uptake (n = 4).Conclusions: This prospective multicenter trial of 123I‐mIBG scintigraphy documents high sensitivity and specificity of this imaging technique in patients with both newly diagnosed and previously treated neuroblastoma. Pediatr Blood Cancer 2009;52:784–790.
- 20 January 2009
- Published by Elsevier in Journal of Nuclear Cardiology
- Vol. 16 (1) , 113-121
123I-mIBG Scintigraphy to predict risk for adverse cardiac outcomes in heart failure patients: Design of two prospective multicenter international trials
- 20 January 2009
- Published by Elsevier in Journal of Nuclear Cardiology
- Vol. 16 (1) , 113-121
123I-mIBG Scintigraphy to predict risk for adverse cardiac outcomes in heart failure patients: Design of two prospective multicenter international trials