3.0-T MR Imaging of the Abdomen: Comparison with 1.5 T
Authors:
- Kevin J. ChangKCKevin J. Chang
- Ihab R. KamelIKIhab R. Kamel
- Katarzyna J. MacuraKMKatarzyna J. Macura
- David A. BluemkeDBDavid A. Bluemke
- 1 November 2008
- journal article
- research article
- Published by Radiological Society of North America (RSNA) in RadioGraphics
- Vol. 28 (7) , 1983-1998
Abstract
Three-tesla magnetic resonance (MR) imaging offers substantially higher signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) than 1.5-T MR imaging does, which can be used to improve image resolution and shorten imaging time. Because of these increases in SNR and CNR, as well as changes in T1 and T2 relaxation times, an increase in magnetic susceptibility, and an increase in chemical shift effect, many abdominal applications can benefit from 3.0-T imaging. Increased CNR obtained with a gadolinium-based contrast agent improves lesion conspicuity, requires less intravenous contrast material, and improves MR angiography by increasing spatial and temporal resolution. Increased SNR improves fluid conspicuity and resolution for applications such as MR cholangiopancreatography. Increased chemical shift effect also improves spectral resolution for MR spectroscopy. Several potential problems remain for abdominal imaging at 3.0 T. Limitations on energy deposition may require compromises in pulse sequence timing and flip angles. These compromises result in prolonged imaging time and altered image contrast. Magnetic susceptibility and chemical shift artifacts are worsened, but they may be counteracted by shortening echo time, performing parallel imaging, and increasing bandwidth. Radiofrequency field inhomogeneity is also a major concern in imaging larger fields of view and often leads to standing wave effects and large local variations in signal intensity. Many issues related to MR device compatibility and safety have yet to be addressed at 3.0 T. A 3.0-T MR imaging system has a higher initial cost and a higher cost of upkeep than a 1.5-T system does.Keywords
This publication has 49 references indexed in Scilit:
- Diffusion-Weighted MRI in the Body: Applications and Challenges in OncologyAmerican Journal of Roentgenology, 2007
- MRCP imaging at 3.0 T vs. 1.5 T: Preliminary experience in healthy volunteersJournal of Magnetic Resonance Imaging, 2007
- Diffusion‐weighted MRI (DWI) in the oncology patient: Value of breathhold DWI compared to unenhanced and gadolinium‐enhanced MRIJournal of Magnetic Resonance Imaging, 2007
- High-B-Value Diffusion-Weighted MRI in Colorectal CancerAmerican Journal of Roentgenology, 2006
- Superparamagnetic Iron Oxide-Enhanced Liver Magnetic Resonance ImagingInvestigative Radiology, 2006
- Evaluation of intrarenal oxygenation by BOLD MRI at 3.0TJournal of Magnetic Resonance Imaging, 2004
- Breathhold abdominal and thoracic proton MR spectroscopy at 3TMagnetic Resonance in Medicine, 2003
- Single breath‐hold diffusion‐weighted imaging of the abdomenJournal of Magnetic Resonance Imaging, 2003
- Needle localization in MR-guided biopsy and aspiration: effects of field strength, sequence design, and magnetic field orientation.American Journal of Roentgenology, 1996
- “Keyhole” method for accelerating imaging of contrast agent uptakeJournal of Magnetic Resonance Imaging, 1993