PCEA compared to continuous epidural infusion in an ultra‐low‐dose regimen for labor pain relief: a randomized study
- 9 September 2003
- journal article
- clinical trial
- Published by Wiley in Acta Anaesthesiologica Scandinavica
- Vol. 47 (9) , 1085-1090
Abstract
Background: Patient‐controlled epidural analgesia, PCEA, has been introduced in obstetric analgesia during the past decade. Many studies have shown that the consumption of analgesic is reduced when the parturient requests her own doses. This study investigates whether this is also true when using an ultra‐low‐dose regimen.Methods: Eighty parturients were prospectively randomized to have either continuous epidural infusion (CEI) with ropivacaine 1 mg ml−1 and sufentanil 0.5 µg ml−1, 6 ml h−1, or patient‐controlled epidural analgesia (PCEA) with 4 ml demand doses with 20 min' lockout. The epidural start dose was the same for the two groups, 8 ml of the study solution. Rescue bolus doses were given when needed and the continuous infusion could be increased, which gave the two groups the same maximum possible dose. The consumption of local ropivacaine in combination with sufentanil during labor was registered. Hourly assessments made throughout labor included pain intensity documented with visual analog score, VAS, the patient's opinion on epidural efficacy, motor block, pruritus and need for nitrous oxide.Results: The PCEA group consumed 33% less of the study solution than the CEI group. Mean total consumption was 35 ml (SD 18.0) and 52 ml (SD 19.6), respectively. Mean hourly consumption was 5.2 ml h−1 (SD 2.54) in the PCEA group and 6.9 ml h−1 (SD 1.31) in the CEI group. There were no significant differences between the two groups in pain relief, epidural efficacy, side‐effects or obstetric outcome.Conclusion: PCEA reduces doses compared to continuous infusion even when ultra‐low‐dose local anesthetic with opioid is used. The PCEA technique provides individual titration of doses to an acceptable degree of pain relief.Keywords
This publication has 22 references indexed in Scilit:
- A comparison of three doses of sufentanil in combination with bupivacaine‐adrenaline in continuous epidural analgesia during labourActa Anaesthesiologica Scandinavica, 2000
- Ropivacaine, 0.1%, Plus Sufentanil, 0.5 μg/ml, versus Bupivacaine, 0.1%, Plus Sufentanil, 0.5 μg/ml, Using Patient-controlled Epidural Analgesia for LaborAnesthesiology, 2000
- Motor blockade is reduced with ropivacaine 0.125% for parturient-controlled epidural analgesia during labourCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 1999
- Obstetric outcome following epidural analgesia with bupivacaine‐adrenaline 0.25% or bupivacaine 0.125% with sufentanil ‐ a prospective randomized controlled study in 1000 parturientsActa Anaesthesiologica Scandinavica, 1998
- Patient-controlled epidural analgesia in obstetric anaesthetic practicePain, 1994
- Patient-controlled epidural analgesia in labour: varying bolus dose and lockout intervalCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 1993
- Effects of nitrous oxide/oxygen inhalation on the maternal circulation during vaginal deliveryActa Anaesthesiologica Scandinavica, 1992
- The Effects of the Addition of Sufentanil to 0.125% Bupivacaine on the Quality of Analgesia during Labor and on the Incidence of Instrumental DeliveriesAnesthesiology, 1991
- Patient-controlled Epidural Analgesia during LaborAnesthesiology, 1990
- A comparative study of patient controlled epidural analgesia (PCEA) and continuous infusion epidural analgesia (CIEA) during labourCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 1988