Susanne Ledin Eriksson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Susanne Ledin Eriksson has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
Christina Olofsson
2 shared publicationsC. Gentele
Department of Anaesthesiology and Intensive Care, Söder Hospital, Stockholm, and
1 shared publicationC. H. Olofsson
Department of Anaesthesiology and Intensive Care, Karolinska Hospital, Stockholm, Sweden
1 shared publicationInger Blomberg
1 shared publicationPetra Otterblad Olausson
1 shared publication
Latest Publications
- 1 September 2006
- Published by Elsevier in European Journal of Obstetrics & Gynecology and Reproductive Biology
- Vol. 128 (1-2) , 270-275
Use of epidural analgesia and its relation to caesarean and instrumental deliveries—a population-based study of 94,217 primiparae
- 1 September 2006
- Published by Elsevier in European Journal of Obstetrics & Gynecology and Reproductive Biology
- Vol. 128 (1-2) , 270-275
Use of epidural analgesia and its relation to caesarean and instrumental deliveries—a population-based study of 94,217 primiparae
- 1 October 2003
- Published by Elsevier in European Journal of Obstetrics & Gynecology and Reproductive Biology
- Vol. 110 (2) , 131-135
Single-shot intrathecal sufentanil with bupivacaine in late labour—analgesic quality and obstetric outcome
- 1 October 2003
- Published by Elsevier in European Journal of Obstetrics & Gynecology and Reproductive Biology
- Vol. 110 (2) , 131-135
Single-shot intrathecal sufentanil with bupivacaine in late labour—analgesic quality and obstetric outcome
- 9 September 2003
- Published by Wiley in Acta Anaesthesiologica Scandinavica
- Vol. 47 (9) , 1085-1090
PCEA compared to continuous epidural infusion in an ultra‐low‐dose regimen for labor pain relief: a randomized study
Background: Patient‐controlled epidural analgesia, PCEA, has been introduced in obstetric analgesia during the past decade. Many studies have shown that the consumption of analgesic is reduced when the parturient requests her own doses. This study investigates whether this is also true when using an ultra‐low‐dose regimen.Methods: Eighty parturients were prospectively randomized to have either continuous epidural infusion (CEI) with ropivacaine 1 mg ml−1 and sufentanil 0.5 µg ml−1, 6 ml h−1, or patient‐controlled epidural analgesia (PCEA) with 4 ml demand doses with 20 min' lockout. The epidural start dose was the same for the two groups, 8 ml of the study solution. Rescue bolus doses were given when needed and the continuous infusion could be increased, which gave the two groups the same maximum possible dose. The consumption of local ropivacaine in combination with sufentanil during labor was registered. Hourly assessments made throughout labor included pain intensity documented with visual analog score, VAS, the patient's opinion on epidural efficacy, motor block, pruritus and need for nitrous oxide.Results: The PCEA group consumed 33% less of the study solution than the CEI group. Mean total consumption was 35 ml (SD 18.0) and 52 ml (SD 19.6), respectively. Mean hourly consumption was 5.2 ml h−1 (SD 2.54) in the PCEA group and 6.9 ml h−1 (SD 1.31) in the CEI group. There were no significant differences between the two groups in pain relief, epidural efficacy, side‐effects or obstetric outcome.Conclusion: PCEA reduces doses compared to continuous infusion even when ultra‐low‐dose local anesthetic with opioid is used. The PCEA technique provides individual titration of doses to an acceptable degree of pain relief.
- 9 September 2003
- Published by Wiley in Acta Anaesthesiologica Scandinavica
- Vol. 47 (9) , 1085-1090
PCEA compared to continuous epidural infusion in an ultra‐low‐dose regimen for labor pain relief: a randomized study
Background: Patient‐controlled epidural analgesia, PCEA, has been introduced in obstetric analgesia during the past decade. Many studies have shown that the consumption of analgesic is reduced when the parturient requests her own doses. This study investigates whether this is also true when using an ultra‐low‐dose regimen.Methods: Eighty parturients were prospectively randomized to have either continuous epidural infusion (CEI) with ropivacaine 1 mg ml−1 and sufentanil 0.5 µg ml−1, 6 ml h−1, or patient‐controlled epidural analgesia (PCEA) with 4 ml demand doses with 20 min' lockout. The epidural start dose was the same for the two groups, 8 ml of the study solution. Rescue bolus doses were given when needed and the continuous infusion could be increased, which gave the two groups the same maximum possible dose. The consumption of local ropivacaine in combination with sufentanil during labor was registered. Hourly assessments made throughout labor included pain intensity documented with visual analog score, VAS, the patient's opinion on epidural efficacy, motor block, pruritus and need for nitrous oxide.Results: The PCEA group consumed 33% less of the study solution than the CEI group. Mean total consumption was 35 ml (SD 18.0) and 52 ml (SD 19.6), respectively. Mean hourly consumption was 5.2 ml h−1 (SD 2.54) in the PCEA group and 6.9 ml h−1 (SD 1.31) in the CEI group. There were no significant differences between the two groups in pain relief, epidural efficacy, side‐effects or obstetric outcome.Conclusion: PCEA reduces doses compared to continuous infusion even when ultra‐low‐dose local anesthetic with opioid is used. The PCEA technique provides individual titration of doses to an acceptable degree of pain relief.