Cardiac resynchronization therapy beyond nominal settings: who needs individual programming of the atrioventricular and interventricular delay?
Open Access
- 28 June 2012
- journal article
- clinical trial
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 14 (12) , 1746-1753
Abstract
This study aimed to determine the additional acute haemodynamic effect of atrioventricular (AV) and interventricular (VV) delay optimization compared with current nominal cardiac resynchronization therapy (CRT) device settings, and to explore whether clinical characteristics correlate to the effect of optimization. Fifty CRT patients were prospectively enrolled. The optimal AV and VV delays were guided by relative improvement in maximum rate of left ventricular (LV) pressure rise (%dP/dtmax). A significant improvement in %dP/dtmax was obtained by optimization in 23–33% (sensed AV delay), 32–57% (paced AV delay), and 45% of patients (VV delay). Adjustment of the device nominal VV delay from 0 to 40 ms LV pre-activation would diminish the proportion of patients with additional effect of individual optimization from 45 to 15%. Heart failure aetiology [ischaemic 2 ± 2 vs. non-ischaemic 1 ± 1 percentage points (PP) %dP/dtmax, P= 0.013], gender (men 2 ± 2 vs. women 1 ± 1 PP %dP/dtmax, P= 0.012) and intrinsic PR interval (R= 0.49, P= 0.002) correlated to the degree of effect of AV delay optimization. Women yielded more effect of VV delay optimization (4 ± 3 vs. 2 ± 1 PP %dP/dtmax, P= 0.026). Compared with the best of the currently available device nominal AV and VV delays, 23–45% of CRT patients can yield additional acute haemodynamic effect by individual optimization of the delays. A new nominal VV delay of 40 ms LV pre-activation is recommended. Male gender, ischaemic aetiology, and longer PR interval are associated with a larger effect of individual optimization.Keywords
This publication has 21 references indexed in Scilit:
- Primary Results From the SmartDelay Determined AV Optimization: A Comparison to Other AV Delay Methods Used in Cardiac Resynchronization Therapy (SMART-AV) TrialCirculation, 2010
- Optimization of AV and VV Delays in the Real‐World CRT Patient Population: An International Survey on Current Clinical PracticePacing and Clinical Electrophysiology, 2009
- Reduced Ventricular Volumes and Improved Systolic Function With Cardiac Resynchronization TherapyCirculation, 2007
- Randomized comparison of simultaneous biventricular stimulation versus optimized interventricular delay in cardiac resynchronization therapyAmerican Heart Journal, 2006
- The Effect of Cardiac Resynchronization on Morbidity and Mortality in Heart FailureThe New England journal of medicine, 2005
- Randomized prospective trial of atrioventricular delay programming for cardiac resynchronization therapyHeart Rhythm, 2004
- Cardiac-Resynchronization Therapy with or without an Implantable Defibrillator in Advanced Chronic Heart FailureThe New England journal of medicine, 2004
- Cardiac Resynchronization in Chronic Heart FailureThe New England journal of medicine, 2002
- Effects of Multisite Biventricular Pacing in Patients with Heart Failure and Intraventricular Conduction DelayThe New England journal of medicine, 2001
- Effect of Pacing Chamber and Atrioventricular Delay on Acute Systolic Function of Paced Patients With Congestive Heart FailureCirculation, 1999