MBMargot D. Bogaard

Margot D. Bogaard

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Margot D. Bogaard has a total of 8 co-authors. Here are the top co-authors by number of shared publications:

  • Anton E. Tuinenburg

    Department of Cardiology , University Medical Center Utrecht , Utrecht , The Netherlands

    2 shared publications
  • Mathias Meine

    Department of Cardiology , University Medical Center Utrecht , Utrecht , The Netherlands

    2 shared publications
  • Peter Loh

    Department of Cardiology , University Medical Center Utrecht , Utrecht , The Netherlands

    2 shared publications
  • Pieter A. Doevendans

    Department of Cardiology , University Medical Center Utrecht , Utrecht , The Netherlands

    2 shared publications
  • Barun Maskara

    Boston Scientific Corporation , St Paul, MN , USA

    1 shared publication
  • Maarten J. Cramer

    University Medical Center Utrecht, Department of Cardiology, Utrecht, the Netherlands

    1 shared publication

Latest Publications

  • Open Access

    Cardiac resynchronization therapy beyond nominal settings: who needs individual programming of the atrioventricular and interventricular delay?

    by Margot D. Bogaard, Mathias Meine, Anton E. Tuinenburg, Barun Maskara, Peter Loh, Pieter A. Doevendans

    This study aimed to determine the additional acute haemodynamic effect of atrioventricular (AV) and interventricular (VV) delay optimization compared with current nominal cardiac resynchronization therapy (CRT) device settings, and to explore whether clinical characteristics correlate to the effect of optimization. Fifty CRT patients were prospectively enrolled. The optimal AV and VV delays were guided by relative improvement in maximum rate of left ventricular (LV) pressure rise (%dP/dtmax). A significant improvement in %dP/dtmax was obtained by optimization in 23–33% (sensed AV delay), 32–57% (paced AV delay), and 45% of patients (VV delay). Adjustment of the device nominal VV delay from 0 to 40 ms LV pre-activation would diminish the proportion of patients with additional effect of individual optimization from 45 to 15%. Heart failure aetiology [ischaemic 2 ± 2 vs. non-ischaemic 1 ± 1 percentage points (PP) %dP/dtmax, P= 0.013], gender (men 2 ± 2 vs. women 1 ± 1 PP %dP/dtmax, P= 0.012) and intrinsic PR interval (R= 0.49, P= 0.002) correlated to the degree of effect of AV delay optimization. Women yielded more effect of VV delay optimization (4 ± 3 vs. 2 ± 1 PP %dP/dtmax, P= 0.026). Compared with the best of the currently available device nominal AV and VV delays, 23–45% of CRT patients can yield additional acute haemodynamic effect by individual optimization of the delays. A new nominal VV delay of 40 ms LV pre-activation is recommended. Male gender, ischaemic aetiology, and longer PR interval are associated with a larger effect of individual optimization.


  • The ECG in Cardiac Resynchronization Therapy: Influence of Left and Right Ventricular Preactivation and Relation to Acute Response

    by Margot D. Bogaard, Tim Hesselink, Mathias Meine, Peter Loh, Richard N. Hauer, Maarten J. Cramer, Pieter A. Doevendans, Anton E. Tuinenburg

    Influence of Preactivation on the ECG in CRT. Introduction: The aims of this study were to compare ECG signs of biventricular electrical resynchronization during cardiac resynchronization therapy (CRT) with various interventricular (VV) delays and to correlate these and other ECG characteristics with the acute hemodynamic benefit of CRT. Methods and Results: Thirty‐four patients with heart failure and a left bundle branch block (LBBB) pattern were prospectively enrolled. A 12‐lead surface ECG and the relative improvement in left ventricular (LV) dP/dtmax (the maximum rate of pressure rise) were recorded at baseline and during CRT with VV delays varying from 80 ms LV preactivation to 40 ms right ventricular (RV) preactivation. Rightward QRS‐axis shift occurred in 71–80% among all VV delays. Activation reversal to dominant negative in leads I/aVL was progressively observed at increasing LV preactivation (53–65%) and less (18–22%) during RV preactivation. Activation reversal to dominant positive in leads V1/V2 was observed in 21–27% during LV preactivation and in 6–15% during RV preactivation. Higher acute response to CRT was independently predicted by a complete LBBB at baseline (regression coefficient B = 7.7 [0.3–15.0], P = 0.042), later timing of LV depolarization within the QRS at baseline (Q‐LVsense: B = 0.2 [0.1–0.3], P = 0.002), and biventricular electrical resynchronization during CRT as evidenced by activation reversal in leads I/aVL (B = 9.9 [3.2–16.6], P = 0.005). Conclusion: ECG signs of biventricular electrical resynchronization are present over a wide range of LV preactivated VV delays but to a lesser extent during RV preactivation. The presence of complete LBBB and longer Q‐LVsense at baseline and signs of biventricular electrical resynchronization during CRT predict higher acute hemodynamic response. (J Cardiovasc Electrophysiol, Vol. 23, pp. 1237–1245, November 2012)